ADTRAN 2 x E1 user manual Freq

Page 16

61280004L2-1C

Section 1 TRACER Description

 

E1A

E1B

FREQ

SYSTEMTRACER

 

ALM

ALM

 

 

TEST

LBK

LBK

PLAN A

RF LOW

POWER

CV/CRC

CV/CRC

PLAN B

LINK DOWN

LOS/OOF

LOS/OOF

 

 

 

Figure 1-6. BBP Front Panel with Door Closed

1 2 3 4

1

2

 

0

 

9 8

3

 

4

 

5

7

6

 

TEST

ALM

LBK

HDB3

HDB3

ALM

LBK

 

RESET

LBKA

CAS

CAS

 

LBKB

PWR

LOS

CV

CCS

CCS

LOS

CV

AMI

AMI

 

OOF

CRC

OOF

CRC

 

 

 

 

 

GND

L

RSSI

+5

+12

A

TST

RF LOW

 

 

 

 

 

 

 

 

 

TEST

 

UP

 

 

 

 

 

 

 

 

CODE

DOWN

CLK

Q

RF

-5

-12

B

FAIL

LINK

TX PWR

 

 

 

 

 

 

 

PWR

 

 

 

 

 

E1A

E1B

PLAN

REMOTE

ERROR

Figure 1-7. BBP Front Panel with Door Open

As a rule, a green LED indicates a normal situation, a red LED indicates an error situation, and a yellow LED indicates a configuration option. LEDs indicating overall system integrity are listed below.

Self Test

Blinking red if the self-test has completed and failed; Solid red if

 

self-test is in progress or did not complete

Power

Green if DC voltage is applied

The LEDs associated with the E1 interfaces are listed below.

CV/CRC

Red if the incoming E1 stream contains code violations, or a CRC

 

error

LOS/OOF

Red if there is no signal present at the E1 interfaces or if framing

 

synchronization is lost

Loopback

Solid yellow if the E1 interfaces are in local line loopback. Blinking

 

yellow if the E1 interfaces are in link loopback.

ALM

Solid red if a UA1 is detected at the incoming E1, blinking red if a

 

remote alarm signal is found

The functions of the LEDs which relate system configuration information are listed below.

Frequency Plan A

Yellow if frequency plan A is selected

Frequency Plan B

Yellow if frequency plan B is selected

Remote Test Active

Yellow if the remote test is active

Remote Test Fail

Red if the remote test failed

6

TRACER 2 x E1 User’s Manual

Image 16
Contents Tracer 2 x E1 User’s Manual 61280004L2-1C Radio Frequency Interface Statement R N I N GRadio Frequency Interference Statement Table of Contents Operation Troubleshooting Specifications Warranty, Ordering and Return InformationGlossary Appendix aIllustrations Viii Tracer Description IntroductionApplications Spread SpectrumForward Error Correction Tracer DescriptionChannel Selection Direct SequenceE1 Interfaces Tracer System ConfigurationBaseband Processor or BBP Block diagram of the BBP is shown in Figure VT100 RS-232 InterfaceAlarm Contacts If SignalPower Controls and IndicatorsFreq Name Function Non-volatile MemoryBuilt-In Tests Radio Frequency Converter or RFC10. Front and Rear of Rackmount RFC Housing Antenna Selection Antenna 100 mWInstallation UNPACK, InspectInstallation Grounding15 Pin RJ-48 E1 InterfacesLink Planning P O R T a N TAntenna Feedline Loss Antenna GainPath Loss Path AvailabilitySetting the Transmitter Power GHZ, 1 Watt Transmitter OptionSetting the RFC Frequency Plan on NON 1 Watt 2.4 GHZ Models 4 GHz DiplexerPlan a Plan B Setting the RFC Frequency Plan on 5.8 GHZ Models 8 GHz DiplexerConnecting the BBP and the RFC Applying PowerAutomatic BBP Frequency Plan Spreading CodeAntenna Alignment CO-LOCATING Multiple SystemsRF LOW Alarm Contacts Remote BertInstallation Password OperationVT100 User Interface RS-232 InterfaceMain Menu Selections OperationSystem Status Screen Main Menu Screen Tracer Main MenuE1 Status / Configuration / Loopback E1A Status ScreenLink Performance History Link Performance History ScreenE1A Statistics E1B StatisticsSectionTROUBLESHOOTING4 Troubleshooting Problem Descriptions and Recommended ActionsTroubleshooting Using the Front Panel Indicators GeneralCV/CRC Light on E1A or E1B is Lit when CRC is enabled TroubleshootingRecommended Actions LBK-A or LBK-B is Lit LOS/OOF Light on E1A or E1BNo Power Light ALM is LitTest Light is Lit or Blinking TST Light is Lit After Pressing Remote Test ButtonFail Light is Lit After Pressing Remote Test Button RF Low Light is OnLOS Alarm Troubleshooting Using the VT100 User InterfaceCV Alarm CRC Alarm OOF AlarmRMT Alarm UA1 Alarm Code Sync Status Carrier Sync Status or E1 Mux Sync Status RFC Link Up Status Possible CauseES Values in E1A or E1B Performance History Menu SES Values in E1A or E1B Performance History Menu Troubleshooting Specifications Specifications PowerVT100 Terminal Interface Mechanical & EnvironmentalWARRANTY, Ordering and Return WarrantySales Repairs and ReturnsWarranty, Ordering and Return Information Glossary Acronyms Used in this ManualGlossary Appendix a Cable Connections Terminal Connection DB-25Personal Computer Connection DB-9 Modem Connection DB-25Appendix a Cable Connections