SECTION 5 SPECIFICATIONS
This section lists the specifications for the TRACER system.
Transmitter
Output Power |
|
100 mW Transmitter | +20 dBm, maximum |
1 W Transmitter | +30 dBm, maximum (Factory preset to +27 dBm) |
Frequency Range | 5725 to 5850 MHz or 2400 to 2483.5 MHz |
Channel Bandwidth | 62 MHz (5.8 GHz) or 40 MHz (2.4 GHz), (two channels) |
IF | 140 MHz |
Receiver
Receive Level, range | |
Receive Level, maximum | |
Receive Level, nominal | |
IF | 70 MHz |
Frequency Plan
Plan A 2.4 GHz | Tx 2.421 GHz, Rx 2.462 GHz |
Plan B 2.4 GHz | Tx 2.462 GHz, Rx 2.421 GHz |
Plan A 5.7 GHz | Tx 5.747 GHz, Rx 5.827 GHz |
Plan B 5.7 GHz | Tx 5.827 GHz, Rx 5.747 GHz |
Spread Spectrum Data Pump
Modulation | QPSK |
Spreading Method | Direct sequence |
Code Length | 120 bits |
Processing Gain | >12 dB |
Number of Codes | 10 |
Chipping Rate | 12 times |
Interface Specifications
Capacity | 2 x E1 |
Connection | |
Line Code | AMI, HDB3 |
Framing | CAS, CCS |
Alarms | LOS, OOF, CV, CRC, RMT, UA1 |
Loopbacks | Local and remote, per E1 channel |
User Interface
Front Panel | Alarm LEDs, Configuration Switches, Monitor Jacks |
Diagnostics | E1 Loopback, Remote Test with |
TRACER 2 x E1 User’s Manual | 45 |