Section 2 Installation

REMOTE BERT

The TRACER includes a Bit Error Rate Tester (BERT) to verify that the installed system is operating correctly. When the “Remote Test” button is pushed on the local BBP, the remote end will send a BERT pattern for approximately ten seconds. The “Remote TST” indicator will turn yellow and remain on for the duration of the test. If no bit errors are detected, the “Remote TST” indicator will turn off. If any bit errors are detected, the “Remote Fail” indicator will turn red. This test should be run after the radio link has been aligned. If the test fails, refer to Section 4, “Troubleshooting,” for guidance.

ALARM CONTACTS

Two classes of alarm, MAJOR and MINOR, are provided. A MAJOR alarm is signaled when the microwave path is not operational. A MINOR alarm is activated when any of the following conditions are detected at one of the E1 interfaces:

Loss of Signal

Code Violation

CRC error

Framing Error

Remote Error

UA1

Both normally-open and normally-closed contacts are provided for each alarm class. Access is provided by a six-position terminal strip on the baseband processor.

TRACER 2 x E1 User’s Manual

23

Image 33
Contents Tracer 2 x E1 User’s Manual 61280004L2-1C R N I N G Radio Frequency Interface StatementRadio Frequency Interference Statement Table of Contents Operation Troubleshooting Warranty, Ordering and Return Information SpecificationsGlossary Appendix aIllustrations Viii Introduction Tracer DescriptionApplications Spread SpectrumTracer Description Forward Error CorrectionChannel Selection Direct SequenceTracer System Configuration E1 InterfacesBaseband Processor or BBP VT100 RS-232 Interface Block diagram of the BBP is shown in FigureIf Signal Alarm ContactsPower Controls and IndicatorsFreq Non-volatile Memory Name FunctionRadio Frequency Converter or RFC Built-In Tests10. Front and Rear of Rackmount RFC Housing Antenna 100 mW Antenna SelectionUNPACK, Inspect InstallationGrounding InstallationE1 Interfaces 15 Pin RJ-48P O R T a N T Link PlanningAntenna Gain Antenna Feedline LossPath Availability Path LossGHZ, 1 Watt Transmitter Option Setting the Transmitter Power4 GHz Diplexer Setting the RFC Frequency Plan on NON 1 Watt 2.4 GHZ ModelsPlan a Plan B 8 GHz Diplexer Setting the RFC Frequency Plan on 5.8 GHZ ModelsApplying Power Connecting the BBP and the RFCAutomatic BBP Frequency Plan Spreading CodeCO-LOCATING Multiple Systems Antenna AlignmentRF LOW Remote Bert Alarm ContactsInstallation Operation PasswordVT100 User Interface RS-232 InterfaceOperation Main Menu SelectionsSystem Status Screen Tracer Main Menu Main Menu ScreenE1A Status Screen E1 Status / Configuration / LoopbackLink Performance History Screen Link Performance HistoryE1B Statistics E1A StatisticsProblem Descriptions and Recommended Actions SectionTROUBLESHOOTING4 TroubleshootingTroubleshooting Using the Front Panel Indicators GeneralTroubleshooting CV/CRC Light on E1A or E1B is Lit when CRC is enabledRecommended Actions LOS/OOF Light on E1A or E1B LBK-A or LBK-B is LitALM is Lit No Power LightTST Light is Lit After Pressing Remote Test Button Test Light is Lit or BlinkingRF Low Light is On Fail Light is Lit After Pressing Remote Test ButtonTroubleshooting Using the VT100 User Interface LOS AlarmCV Alarm OOF Alarm CRC AlarmRMT Alarm UA1 Alarm Code Sync Status Carrier Sync Status or E1 Mux Sync Status Possible Cause RFC Link Up StatusES Values in E1A or E1B Performance History Menu SES Values in E1A or E1B Performance History Menu Troubleshooting Specifications Power SpecificationsVT100 Terminal Interface Mechanical & EnvironmentalWarranty WARRANTY, Ordering and ReturnSales Repairs and ReturnsWarranty, Ordering and Return Information Acronyms Used in this Manual GlossaryGlossary Terminal Connection DB-25 Appendix a Cable ConnectionsPersonal Computer Connection DB-9 Modem Connection DB-25Appendix a Cable Connections