Section 2 Installation
9.Reattach the cable assemblies from the ports labelled “Tx” and “Rx” on the RFC and the ports labelled “J1” and “J2” on the diplexer. Cable connections should be aligned to each other as follows.
Plan A | Plan B |
RF converter Tx connected to | RF converter Tx connected to |
Diplexer Port J1 | Diplexer Port J2 |
RF converter Rx connected to | RF converter Rx connected to |
Diplexer Port J2 | Diplexer Port J1 |
10. Replace and secure the RFC cover. |
|
For mastmounted systems, do the following to reconfigure the RFC interconnect:
1.Remove the lid of the mast RFC.
2.Disconnect the three cables attached to the diplexer. The diplexer may be identified by following the antenna connector to the middle connector of the diplexer. Leave the cables in the same positions.
3.Remove the two screws securing the diplexer and rotate the diplexer to reveal the opposite frequency plan label.
4.Reinstall the two screws and reattach the cables in the same positions – Minimum bend radius on cables is 3/4 inches (2 cm). Exercise care in handling and forming bends in these cables.
5.Reinstall the lid of the mast RFC.
TRACER 2 x E1 User’s Manual | 19 |