ADTRAN 2 x E1 user manual Antenna Feedline Loss, Antenna Gain

Page 25

61280004L2-1C

Section 2 Installation

Antenna Feedline Loss

Feedline loss is a function of feedline type and length. Feedline loss per 30.48 meters (100 feet) for several types of coax at IF and RF frequencies is detailed in the table below. The IF loss applies to BBP/ RFC interconnection, and the RF loss applies to RFC/antenna interconnection. Cable manufacturers’ specifications may vary.

 

 

IF Loss/100 feet

2.4 GHz RF Loss/100 feet

5.7 GHz RF Loss/100 feet

Cable

 

(in dB)

 

 

(in dB)

 

 

(in dB)

 

RG58

5.7

80

 

N/A

RG8 (air)

2.7

20

 

N/A

RG8 (foam)

2

9

 

N/A

1/ " Coax

1.42

5.91

11.36

 

 

4

 

 

 

 

 

 

 

 

 

3/ " Coax

1.25

5.76

9.65

 

 

8

 

 

 

 

 

 

 

 

 

1/ " Coax

0.81

3.83

6.49

 

 

2

 

 

 

 

 

 

 

 

 

7/ " Coax

0.44

2.2

 

N/A

 

8

 

 

 

 

 

 

 

 

 

1

1/ " Coax

0.33

1.62

 

N/A

 

4

 

 

 

 

 

 

 

 

 

1

5/ " Coax

0.27

1.41

 

N/A

 

8

 

 

 

 

 

 

 

 

 

5.8 GHz Elliptical Waveguide

N/A

N/A

1.23

 

Antenna Gain

Best performance will result from the use of a parabolic dish antenna. Antenna gain is determined by the size of the dish, with typical figures detailed below. Dish manufacturers will be able to supply gains for other types of antenna.

Dish Diameter

2.4 GHz Gain

5.8 GHz Gain

(in cm)

(in dBi)

(in dBi)

60

21

28.5

120

27

34.2

180

31

37.5

243

33

40.7

304

35

42.5

365

37

44.2

TRACER 2 x E1 User’s Manual

15

Image 25
Contents Tracer 2 x E1 User’s Manual 61280004L2-1C R N I N G Radio Frequency Interface StatementRadio Frequency Interference Statement Table of Contents Operation Troubleshooting Warranty, Ordering and Return Information SpecificationsGlossary Appendix aIllustrations Viii Introduction Tracer DescriptionApplications Spread SpectrumTracer Description Forward Error CorrectionChannel Selection Direct SequenceE1 Interfaces Tracer System ConfigurationBaseband Processor or BBP VT100 RS-232 Interface Block diagram of the BBP is shown in FigureIf Signal Alarm ContactsPower Controls and IndicatorsFreq Non-volatile Memory Name FunctionRadio Frequency Converter or RFC Built-In Tests10. Front and Rear of Rackmount RFC Housing Antenna 100 mW Antenna SelectionUNPACK, Inspect InstallationGrounding InstallationE1 Interfaces 15 Pin RJ-48P O R T a N T Link PlanningAntenna Gain Antenna Feedline LossPath Availability Path LossGHZ, 1 Watt Transmitter Option Setting the Transmitter Power4 GHz Diplexer Setting the RFC Frequency Plan on NON 1 Watt 2.4 GHZ ModelsPlan a Plan B 8 GHz Diplexer Setting the RFC Frequency Plan on 5.8 GHZ ModelsApplying Power Connecting the BBP and the RFCAutomatic BBP Frequency Plan Spreading CodeAntenna Alignment CO-LOCATING Multiple SystemsRF LOW Remote Bert Alarm ContactsInstallation Operation PasswordVT100 User Interface RS-232 InterfaceMain Menu Selections OperationSystem Status Screen Tracer Main Menu Main Menu ScreenE1A Status Screen E1 Status / Configuration / LoopbackLink Performance History Screen Link Performance HistoryE1B Statistics E1A StatisticsProblem Descriptions and Recommended Actions SectionTROUBLESHOOTING4 TroubleshootingTroubleshooting Using the Front Panel Indicators GeneralCV/CRC Light on E1A or E1B is Lit when CRC is enabled TroubleshootingRecommended Actions LOS/OOF Light on E1A or E1B LBK-A or LBK-B is LitALM is Lit No Power LightTST Light is Lit After Pressing Remote Test Button Test Light is Lit or BlinkingRF Low Light is On Fail Light is Lit After Pressing Remote Test ButtonLOS Alarm Troubleshooting Using the VT100 User InterfaceCV Alarm CRC Alarm OOF AlarmRMT Alarm UA1 Alarm Code Sync Status Carrier Sync Status or E1 Mux Sync Status RFC Link Up Status Possible CauseES Values in E1A or E1B Performance History Menu SES Values in E1A or E1B Performance History Menu Troubleshooting Specifications Power SpecificationsVT100 Terminal Interface Mechanical & EnvironmentalWarranty WARRANTY, Ordering and ReturnSales Repairs and ReturnsWarranty, Ordering and Return Information Acronyms Used in this Manual GlossaryGlossary Terminal Connection DB-25 Appendix a Cable ConnectionsPersonal Computer Connection DB-9 Modem Connection DB-25Appendix a Cable Connections