Allied Telesis AR400 series manual Using the CLI to configure the AR415S, Advanced configuration

Page 21

Installation and Safety Guide

21

6.Save the configuration.

The first time you start the router, it uses the default configuration in the file boot.cfg.

Save your configuration to a new file, and set the router to use this file when it restarts. We strongly recommend leaving the boot.cfg file unchanged, in case you need to revert to the original default configuration. Some wizards save the configuration automatically. If your configuration is not saved yet, the Save button is red.

7.Advanced configuration.

If necessary, use the command line to complete the configuration if necessary (“Using the CLI to configure the AR415S” below). Use the commands in the Software Reference.

Using the CLI to configure the AR415S

This section describes how to access the CLI via a switch port in VLAN1 on the AR415S routers, when the PC and the router are in the same subnet, in order to configure the router.

Caution Only one DHCP server should usually be enabled on a network. If you have an existing DHCP server, we recommend disabling either it or the router’s DHCP server. To disable the router’s DHCP server, use the command:

disable dhcp

If another device on your network already uses the router’s default IP address, do not connect the router to the network until you have changed the IP address of the router’s default VLAN. Using the command line, enter the command:

set ip interface=vlan1 ip=ipaddress mask=mask

See the Internet Protocol (IP) chapter in the Software Reference.

1.Initiate router start-up.

Using the terminal cable supplied, connect a VT100-compatible terminal, or the COM port of a PC running a terminal emulation program such as Windows Hyper Terminal, to the Console RS-232 (ASYN0) port on the router’s rear panel.

613-000313 Rev C

Image 21
Contents Installation and Safety Guide AR400 Series Router Table of Contents Electrical Safety Statements Models Covered By This Guide Package ContentsAR450S Package Contents AR440S, AR441S and AR442S Package ContentsBefore Installing the Router Installing the AR450SAR450S Router Selecting a SiteApplying Power to the Router Installing the Router in a RackConfiguring the AR450S Using the CLI to configure the AR450SInitiate router start-up Log in and set the password Configure the routerSave the configuration Using the GUI to configure the AR450S Connect the PC to a router switch portAccess the CLI on the router Enable IP Assign an IP address to VLAN1Browse to the GUI Connecting the router to your network Connecting Data Cables to the AR450SConnect to the LAN Connect to the DMZ portSystem LEDs on the AR450S LEDState Function AR415S Router Installing the AR415SInstalling an Optional PIC Installing the Router in a Rack Check the supply voltage and the router’s rated voltage Using the GUI to configure the AR415S Configuring the AR415SSet PC to automatic IP address RouterLog Using the CLI to configure the AR415S Installation and Safety Guide Save the configurationAdvanced configuration At the log in prompt, enter the login name and password Connecting Data Cables to AR415S PWR System LEDs on AR415SSYS PICAR440S, AR441S, AR442S Routers Installing the AR440S, AR441S, AR442SInstalling an Optional PIC Installing the Router in a Rack Installing the Router on a Wall Applying Power to the Router Using the GUI to configure the AR440S, AR441S and AR442S Configuring the AR440S, AR441S, AR442SHub or Layer 2 Switch Installation and Safety Guide Set PC to automatic IP address Configure the router Using the CLI to configure the router Log in and set the password Connecting Data Cables to AR440S, AR441S, AR442S System LEDs on AR440S, AR441S, AR442S AdslShdsl Default Configuration on AR415S, AR440S, AR441S, AR442S Documentation and Tools CD-ROM Important Safety Instructions Connection to mains voltage supplyTelecommunications Interfaces Ports for the connection of other apparatus Connection to Isdn networkTNV1 TNV3Electrical Notices SafetyLightning Danger Lightning Activity Electrical Type Class 1 EquipmentAchtung Gefährliche Spannung SicherheitGefahr Durch Blitzschlag VorsichtElektriske Forholdsregler SikkerhedFare Under Uvejr Lynaktivitet Elektrisk Klasse 1-UDSTYRWaarschuwingen MET Betrekking TOT Elektriciteit VeiligheidGevaar Voor Blikseminslag Elektrische Toestellen VAN KlasseInformation SUR LES Risques Électriques SécuritéAvertissement Danger D’ÉLECTROCUTION Équipement DE Classe 1 ÉlectriqueTurvallisuus Sähköön Liittyviä HuomautuksiaSalamaniskuvaara Norme di Sicurezza Avvertenze ElettrichePericolo DI Fulmini Elektrisitet SikkerhetFare for Lynnedslag Elektrisk Type 1- Klasse UtstyrAvisos Sobre Características Elétricas SegurançaAtenção Perigo DE Choque Elétrico Perigo DE Choque Causado POR RaioAvisos Electricos SeguridadPeligro DE Rayos Temperatura Requerida Para LA OperaciónTillkännagivanden Beträffande Elektricitetsrisk SäkerhetFara FÖR Blixtnedslag Elektriskt TYP Klass 1 UtrustningRJ49C For the AR021U PICFor the AR440S and AR442S routers RJ11CCanadian Department of Communications Category Approval Agency and Requirement Emission Compliance StatementsStandards The AR450S meets the following standards EC Declaration of Conformity We Allied Telesis Labs LimitedNazareth Avenue Christchurch 8024 NEW Zealand