Installation and Safety Guide

29

Configuring the AR440S, AR441S, AR442S

By default, the DHCP server on the router is enabled, and all the switch ports belong to the default VLAN (vlan1), which has an IP address of 192.168.1.1 (“Default Configuration on AR415S, AR440S, AR441S, AR442S” on page 37).

We recommend starting to configure the router using the graphical user interface (GUI), with its easy wizards. If necessary, you can then use the Command line interface (CLI) to complete your configuration.

“Using the GUI to configure the AR440S, AR441S and AR442S” below

“Using the CLI to configure the router” on page 33

Using the GUI to configure the AR440S, AR441S and AR442S

This section describes how to access the GUI via a switch port in the default VLAN (vlan1) on the AR440S, AR441S and AR442S routers, when the PC and the router are in the same subnet, in order to configure the router.

Caution Only one DHCP server should usually be enabled on a network. If you have an existing DHCP server, we recommend disabling either it or the router’s DHCP server. To disable the router’s DHCP server, use the command line to enter the command:

disable dhcp

If another device on your network already uses the router’s default IP address, do not connect the router to the network until you have changed the IP address of the router’s default VLAN (vlan1). Using the command line, enter the command:

set ip interface=vlan1 ip=ipaddress mask=mask

See the Internet Protocol (IP) chapter in the Software Reference.

The GUI requires a PC running a web browser. Supported browsers are Internet Explorer 5.0 or later and Netscape 6.2.2 or later, with JavaScript enabled. If you are using a toolbar or plug-in on your browser to block pop-ups, disable it while using the GUI. The GUI displays detailed configuration options and information in pop-up windows.

613-000313 Rev C

Image 29
Contents Installation and Safety Guide AR400 Series Router Table of Contents Electrical Safety Statements Models Covered By This Guide Package ContentsAR450S Package Contents AR440S, AR441S and AR442S Package ContentsBefore Installing the Router Installing the AR450SAR450S Router Selecting a SiteApplying Power to the Router Installing the Router in a RackInitiate router start-up Configuring the AR450SUsing the CLI to configure the AR450S Save the configuration Log in and set the passwordConfigure the router Access the CLI on the router Using the GUI to configure the AR450SConnect the PC to a router switch port Browse to the GUI Enable IPAssign an IP address to VLAN1 Connecting the router to your network Connecting Data Cables to the AR450SConnect to the LAN Connect to the DMZ portState Function System LEDs on the AR450SLED AR415S Router Installing the AR415SInstalling an Optional PIC Installing the Router in a Rack Check the supply voltage and the router’s rated voltage Using the GUI to configure the AR415S Configuring the AR415SSet PC to automatic IP address RouterLog Advanced configuration Using the CLI to configure the AR415SInstallation and Safety Guide Save the configuration At the log in prompt, enter the login name and password Connecting Data Cables to AR415S PWR System LEDs on AR415SSYS PICAR440S, AR441S, AR442S Routers Installing the AR440S, AR441S, AR442S Installing an Optional PIC Installing the Router in a Rack Installing the Router on a Wall Applying Power to the Router Using the GUI to configure the AR440S, AR441S and AR442S Configuring the AR440S, AR441S, AR442SHub or Layer 2 Switch Installation and Safety Guide Set PC to automatic IP address Configure the router Using the CLI to configure the router Log in and set the password Connecting Data Cables to AR440S, AR441S, AR442S Shdsl System LEDs on AR440S, AR441S, AR442SAdsl Default Configuration on AR415S, AR440S, AR441S, AR442S Documentation and Tools CD-ROM Telecommunications Interfaces Important Safety InstructionsConnection to mains voltage supply Ports for the connection of other apparatus Connection to Isdn networkTNV1 TNV3Electrical Notices SafetyLightning Danger Lightning Activity Electrical Type Class 1 EquipmentAchtung Gefährliche Spannung SicherheitGefahr Durch Blitzschlag VorsichtElektriske Forholdsregler SikkerhedFare Under Uvejr Lynaktivitet Elektrisk Klasse 1-UDSTYRWaarschuwingen MET Betrekking TOT Elektriciteit VeiligheidGevaar Voor Blikseminslag Elektrische Toestellen VAN KlasseInformation SUR LES Risques Électriques SécuritéAvertissement Danger D’ÉLECTROCUTION Équipement DE Classe 1 ÉlectriqueSalamaniskuvaara TurvallisuusSähköön Liittyviä Huomautuksia Pericolo DI Fulmini Norme di SicurezzaAvvertenze Elettriche Elektrisitet SikkerhetFare for Lynnedslag Elektrisk Type 1- Klasse UtstyrAvisos Sobre Características Elétricas SegurançaAtenção Perigo DE Choque Elétrico Perigo DE Choque Causado POR RaioAvisos Electricos SeguridadPeligro DE Rayos Temperatura Requerida Para LA OperaciónTillkännagivanden Beträffande Elektricitetsrisk SäkerhetFara FÖR Blixtnedslag Elektriskt TYP Klass 1 UtrustningRJ49C For the AR021U PICFor the AR440S and AR442S routers RJ11CCanadian Department of Communications Category Approval Agency and Requirement Emission Compliance StatementsStandards The AR450S meets the following standards Nazareth Avenue Christchurch 8024 NEW Zealand EC Declaration of ConformityWe Allied Telesis Labs Limited