Allied Telesis AR400 series manual Installing the Router in a Rack, Applying Power to the Router

Page 8

8

AR400 Series Router

Installing the Router in a Rack

1.Gather additional items. You will need:

the rack-mount kit included in the router package

a Phillips #1 screwdriver

screws and cage nuts to attach the brackets to your rack

2.Check the rack.

Ensure that the rack is safely secured and that it will not tip over. Devices in a rack should be installed starting at the bottom, with the heavier devices near the bottom of the rack.

Ensure the rack has sufficient space for the router and its associated cables. The router is 1U high.

3.Unscrew the feet from the router.

4.Connect the handles to the brackets.

Screw the handles to the wider side of each bracket, using the supplied screws.

5.Connect the brackets to the router.

Screw the brackets to the sides of the router, using the supplied screws. The router can be front or rear mounted.

6.Mount the router in the rack.

Use appropriate rack mounting screws (not supplied).

Applying Power to the Router

1.Check the supply voltage and the router’s rated voltage.

The router is fitted with a universal mains power supply that will function over the range 100 VAC to 240 VAC and 50 Hz to 60 Hz.

For continued protection against the risk of fire and shock hazard, replace fuses only with fuses of the same type and rating.

Warning The specific power supply requirements for a particular model are clearly displayed on the rear or underside of the router. If the supply is outside the accepted range for the router, the router may not operate or damage to the router may result.

2. Fit the power cord retaining clip to the AC power inlet on the router’s rear panel.

613-000313 Rev C

Image 8
Contents Installation and Safety Guide AR400 Series Router Table of Contents Electrical Safety Statements Package Contents Models Covered By This GuideAR440S, AR441S and AR442S Package Contents AR450S Package ContentsInstalling the AR450S Before Installing the RouterAR450S Router Selecting a SiteInstalling the Router in a Rack Applying Power to the RouterInitiate router start-up Configuring the AR450SUsing the CLI to configure the AR450S Save the configuration Log in and set the passwordConfigure the router Access the CLI on the router Using the GUI to configure the AR450SConnect the PC to a router switch port Browse to the GUI Enable IPAssign an IP address to VLAN1 Connecting Data Cables to the AR450S Connecting the router to your networkConnect to the LAN Connect to the DMZ portState Function System LEDs on the AR450SLED Installing the AR415S AR415S RouterInstalling an Optional PIC Installing the Router in a Rack Check the supply voltage and the router’s rated voltage Configuring the AR415S Using the GUI to configure the AR415SRouter Set PC to automatic IP addressLog Advanced configuration Using the CLI to configure the AR415SInstallation and Safety Guide Save the configuration At the log in prompt, enter the login name and password Connecting Data Cables to AR415S System LEDs on AR415S PWRSYS PICInstalling the AR440S, AR441S, AR442S AR440S, AR441S, AR442S RoutersInstalling an Optional PIC Installing the Router in a Rack Installing the Router on a Wall Applying Power to the Router Configuring the AR440S, AR441S, AR442S Using the GUI to configure the AR440S, AR441S and AR442SHub or Layer 2 Switch Installation and Safety Guide Set PC to automatic IP address Configure the router Using the CLI to configure the router Log in and set the password Connecting Data Cables to AR440S, AR441S, AR442S Shdsl System LEDs on AR440S, AR441S, AR442SAdsl Default Configuration on AR415S, AR440S, AR441S, AR442S Documentation and Tools CD-ROM Telecommunications Interfaces Important Safety InstructionsConnection to mains voltage supply Connection to Isdn network Ports for the connection of other apparatusTNV1 TNV3Safety Electrical NoticesLightning Danger Lightning Activity Electrical Type Class 1 EquipmentSicherheit Achtung Gefährliche SpannungGefahr Durch Blitzschlag VorsichtSikkerhed Elektriske ForholdsreglerFare Under Uvejr Lynaktivitet Elektrisk Klasse 1-UDSTYRVeiligheid Waarschuwingen MET Betrekking TOT ElektriciteitGevaar Voor Blikseminslag Elektrische Toestellen VAN KlasseSécurité Information SUR LES Risques ÉlectriquesAvertissement Danger D’ÉLECTROCUTION Équipement DE Classe 1 ÉlectriqueSalamaniskuvaara TurvallisuusSähköön Liittyviä Huomautuksia Pericolo DI Fulmini Norme di SicurezzaAvvertenze Elettriche Sikkerhet ElektrisitetFare for Lynnedslag Elektrisk Type 1- Klasse UtstyrSegurança Avisos Sobre Características ElétricasAtenção Perigo DE Choque Elétrico Perigo DE Choque Causado POR RaioSeguridad Avisos ElectricosPeligro DE Rayos Temperatura Requerida Para LA OperaciónSäkerhet Tillkännagivanden Beträffande ElektricitetsriskFara FÖR Blixtnedslag Elektriskt TYP Klass 1 UtrustningFor the AR021U PIC RJ49CFor the AR440S and AR442S routers RJ11CCanadian Department of Communications Emission Compliance Statements Category Approval Agency and RequirementStandards The AR450S meets the following standards Nazareth Avenue Christchurch 8024 NEW Zealand EC Declaration of ConformityWe Allied Telesis Labs Limited