3.Connect the provided power cord to the AC power inlet and clip it in place. Switch the router’s power switch to the ON position. The Power LED lights continuously and the System LED lights briefly. The Port LEDs also light briefly.

The router is supplied with an approved power cord that incorporates a moulded plug. It must only be used with the power cord supplied.

If the LEDs fail to light, the most likely cause is that the router is not receiving power. Check that:

the power supply outlet’s switch (if any), and the router’s power switch, are in the ON position

the power cable is securely plugged in

the power supply is operational

Configuring the AR450S

You can configure the router via the command line interface (CLI) or the graphical user interface (GUI). First use the CLI to assign an IP address to the router, then use the CLI or the GUI to complete the configuration.

“Using the CLI to configure the AR450S” below

“Using the GUI to configure the AR450S” on page 11

Using the CLI to configure the AR450S

This section describes how to access the router’s command line interface (CLI) using a terminal or PC connected to the router’s console port.

1.Initiate router start-up.

Using the terminal cable supplied, connect a VT100-compatible terminal, or the COM port of a PC running a terminal emulation program such as Windows Hyper Terminal, to the Console RS-232 (ASYN0) port on the router’s rear panel.

Set the communication parameters on your terminal or terminal emulation program to:

Baud rate: 9600

Data bits: 8

Parity: None

Stop bits: 1

Flow control: Hardware

See the AR400 Series Router Hardware Reference for more information on configuring emulation software.

613-000313 Rev C

Image 9
Contents Installation and Safety Guide AR400 Series Router Table of Contents Electrical Safety Statements Models Covered By This Guide Package ContentsAR450S Package Contents AR440S, AR441S and AR442S Package ContentsBefore Installing the Router Installing the AR450SAR450S Router Selecting a SiteApplying Power to the Router Installing the Router in a RackConfiguring the AR450S Using the CLI to configure the AR450SInitiate router start-up Log in and set the password Configure the routerSave the configuration Using the GUI to configure the AR450S Connect the PC to a router switch portAccess the CLI on the router Enable IP Assign an IP address to VLAN1Browse to the GUI Connecting the router to your network Connecting Data Cables to the AR450SConnect to the LAN Connect to the DMZ portSystem LEDs on the AR450S LEDState Function AR415S Router Installing the AR415SInstalling an Optional PIC Installing the Router in a Rack Check the supply voltage and the router’s rated voltage Using the GUI to configure the AR415S Configuring the AR415SSet PC to automatic IP address RouterLog Using the CLI to configure the AR415S Installation and Safety Guide Save the configurationAdvanced configuration At the log in prompt, enter the login name and password Connecting Data Cables to AR415S PWR System LEDs on AR415SSYS PICAR440S, AR441S, AR442S Routers Installing the AR440S, AR441S, AR442SInstalling an Optional PIC Installing the Router in a Rack Installing the Router on a Wall Applying Power to the Router Using the GUI to configure the AR440S, AR441S and AR442S Configuring the AR440S, AR441S, AR442SHub or Layer 2 Switch Installation and Safety Guide Set PC to automatic IP address Configure the router Using the CLI to configure the router Log in and set the password Connecting Data Cables to AR440S, AR441S, AR442S System LEDs on AR440S, AR441S, AR442S AdslShdsl Default Configuration on AR415S, AR440S, AR441S, AR442S Documentation and Tools CD-ROM Important Safety Instructions Connection to mains voltage supplyTelecommunications Interfaces Ports for the connection of other apparatus Connection to Isdn networkTNV1 TNV3Electrical Notices SafetyLightning Danger Lightning Activity Electrical Type Class 1 EquipmentAchtung Gefährliche Spannung SicherheitGefahr Durch Blitzschlag VorsichtElektriske Forholdsregler SikkerhedFare Under Uvejr Lynaktivitet Elektrisk Klasse 1-UDSTYRWaarschuwingen MET Betrekking TOT Elektriciteit VeiligheidGevaar Voor Blikseminslag Elektrische Toestellen VAN KlasseInformation SUR LES Risques Électriques SécuritéAvertissement Danger D’ÉLECTROCUTION Équipement DE Classe 1 ÉlectriqueTurvallisuus Sähköön Liittyviä HuomautuksiaSalamaniskuvaara Norme di Sicurezza Avvertenze ElettrichePericolo DI Fulmini Elektrisitet SikkerhetFare for Lynnedslag Elektrisk Type 1- Klasse UtstyrAvisos Sobre Características Elétricas SegurançaAtenção Perigo DE Choque Elétrico Perigo DE Choque Causado POR RaioAvisos Electricos SeguridadPeligro DE Rayos Temperatura Requerida Para LA OperaciónTillkännagivanden Beträffande Elektricitetsrisk SäkerhetFara FÖR Blixtnedslag Elektriskt TYP Klass 1 UtrustningRJ49C For the AR021U PICFor the AR440S and AR442S routers RJ11CCanadian Department of Communications Category Approval Agency and Requirement Emission Compliance StatementsStandards The AR450S meets the following standards EC Declaration of Conformity We Allied Telesis Labs LimitedNazareth Avenue Christchurch 8024 NEW Zealand