Radio Shack 20-426 Programming id scan lists manually

Page 49

Beyond the Basics

3.Then, press E. E (EDACS), M (Motorola) or L (LTR) appears depending on the trunked system selected. If the frequency is out of the range of the system chosen in this step, you will hear an error tone, the channel number flashes and an error message appears on the display.

4.Use the e or d key to select the next channel in the bank.

5.Repeat Steps 2 through 4 until all frequencies have been entered.

6.Press SRCH to begin searching the bank you’ve programmed.

Then select the programmed bank by using the keypad.

Notes

To lock out the keypad to prevent reprogramming of talk groups, you can use memory lock (Refer to “Memory Lock”).

If you want to return to the previous menu screen, press HOLD/RESUME in the trunk programming mode.

programming id scan lists manually

When you designate a bank as a trunking bank, your scanner sets up 10 scan lists, which are simply lists used to store your favorite talk group IDs. Each list can contain up to 10 IDs, so you can store a total of 100 IDs for each trunking bank. If you use all the banks for trunking, 1,000 IDs will be available.

Once IDs are stored in lists, you can scan them like you scan conventional frequencies.

1.Select the trunking programming mode and the bank you want to change.

2.Use e or d to choose trunk system, and press E.

3.Use e or d to choose Prog ID, and press E.

49

Image 49
Contents Pro-2051 1,000-Channel Triple Trunking Mobile/Base Scanner Contents Set up your scanner Power your scannerBasics BasicsBeyond the Basics Advanced scanner featuresScanning a private bank Highway patrol alertsSignal Stalker Contents SkywarnWired programming WarrantyHOLD/RESUME Your scanner’s keypadTo Do This Your scanner’s rear view Trunk Your scanner’s displayFCC wants you to know Mounting the scanner in your vehicle Install your scannerFrom a wall outlet Power your scannerThrough your vehicle’s ignition negative ground only Rear View From your vehicle’s cigarrette lighterConnecting an external antenna Connecting the supplied antennaConnect your scanner Use extreme caution when installing or removing an Connecting an external speakerListening Safely Turn on your scanner Set up your scannerSet the squelch Common scanner terms Basics Listen to preprogrammed frequenciesScanning overview Basics Beyond the Basics Advanced scanner featuresChannel storage banks Storing known frequencies into channelsBeyond the Basics Locking out a channel in scanning mode Locking out a channel in hold modeBeyond the Basics Deleting a stored frequency Locking out channelsMemory lock Restoring a locked-out channel in hold modeRestoring all locked-out channels Beyond the Basics Hold/resume Direct channel accessScanning a private bank Changing the priority channel Beyond the Basics Priority scanService scanning Beyond the Basics Band search Setting a search bandSearch hold Data skipStoring search frequencies Beyond the Basics Frequency skipDelay Highway patrol/local police scanning Highway patrol alertsSelecting the state State Code Order Press these buttons Action Beyond the Basics Scan hold Setting the alert tone volumeHighway warning alert Highway patrol priority channels Adjusting alertMuting the alert tone Skip frequenciesTrunked highway frequencies About Skywarn SkywarnNWR Same Programming Fips Programming a Fips codeBeyond the Basics Signal Stalker Setting the signal stalker options Beyond the Basics Using signal stalker Trunk tracking Setting the squelchProgramming trunking frequencies Selecting Trunking System Type Programming id scan lists manually Edacs talk groups Motorola talk groupsReceiving trunked systems LTR talk groupsID scan hold mode ID scan modeID search mode Direct entry id hold modeID search hold mode Programming scan lists during search ID monitor modeDeleting a stored ID Reviewing ID lockout ID lockoutRestoring locked-out IDs Setting priority in trunking mode Setting the delay mode for trunking modeTrunking frequency confirmation Multi-track Moving between scan list memoriesAbout multi-track Programming Edacs system frequencies Edacs trackingBeyond the Basics An Edacs trunked system Special Edacs featuresAFS partial entry Edacs ID blockout Edacs ID range searchEdacs Scat Tracking LTR systemsBeyond the Basics Tracking Motorola systems fleet map programming Preset Fleet Maps E1P1 E1P5 E1P11 User-defined fleet maps Selecting a Preset Fleet MapFleet Map Size Codes Programming a user fleet map Size code restrictionsProgramming a Hybrid system You can only enter within a range of 5-100 kHz, and 5 or Toggling the status bit Control channel only mode Disconnect tone detect option end code If the scanner receives no data from the PC for more than Cloning your scanner Birdies Replacing the fuse in the DC power cordProperly Beyond the Basics Resetting your scannerDrive by patrol cars but do not hear alarms? Frequently asked questions FAQsError appears on the display. What does it mean? If Frequencies SpecificationsGlossary Care Service and repair