Cisco Systems R2001120402, UCS C200 M1 manual Low-Voltage Dimm Considerations Generation M2 Only

Page 65

Chapter 3 Maintaining the Server

Installing or Replacing Components

Low-Voltage DIMM Considerations (Generation M2 Only)

The Generation M2 of this server can be ordered with low-voltage (1.35 V) DIMMs or standard-voltage

(1.5 V) DIMMs. Note the following considerations:

Low-voltage DIMMs within the server must have the identical manufacturer, type, speed, and size.

Low-voltage DIMMs and standard-voltage DIMMs can be mixed in the same server. Note that this causes the system BIOS to default to standard-voltage operation (Performance Mode). That is, the server cannot operate in Power Saving Mode unless all DIMMs are low-voltage DIMMs.

Note CPUs that have a maximum memory frequency less than 1333 MHz support LV DIMMs operating in Power saving Mode only, and do not support Performance mode. However, if your server has one of these CPUs, monitoring output for LV DIMMs will show identical voltages for both Power Saving Mode and Performance Mode. In this case, Performance Mode is not active and its fields only mirror the values from the Power Savings Mode fields.

In Generation M2 only, there is a setting in the BIOS Setup utility that you can use to change the DDR memory mode when the server has all low-voltage DIMMs installed. To access this setting, follow these steps:

Step 1 Enter the BIOS setup utility by pressing the F2 key when prompted during bootup.

Step 2 Select the Advanced tab.

Step 3 Select Low Voltage DDR Mode.

Step 4 In the pop-up window, select either Power Saving Mode or Performance Mode.

Power Saving Mode–Prioritizes low-voltage memory operation. This setting is available only if all DIMMs installed are low-voltage DIMMs.

Performance Mode–Prioritizes performance memory operation. If you mix low-voltage DIMM pairs with standard-voltage DIMM pairs, the system defaults to this setting.

Step 5 Press F10 to save your changes and exit the setup utility.

Memory Mirroring and RAS

The CPUs support memory mirroring only when Channels A and B on CPU 1 are populated with DIMMs that are identical in configuration, size, and speed. Do not populate channel C. If three channels are populated with DIMMs, memory mirroring is automatically disabled.

If DIMMs on CPU 2 are populated, channels D and E must be populated with DIMMs that are identical in configuration, size, and speed. Do not populate channel F. If three channels are populated with DIMMs, memory mirroring is automatically disabled.

If memory mirroring is used, the DRAM size is reduced by 50 percent for reasons of reliability. Memory sparing is not supported.

 

 

Cisco UCS C200 Server Installation and Service Guide

 

 

 

 

 

 

OL-20732-02

 

 

3-25

 

 

 

 

 

Image 65
Contents Cisco UCS C200 Server Installation and Service Guide Page N T E N T S Status LEDs AC Power Cord Illustrations OL-20732-02 Organization Related DocumentationAudience Bewaar Deze Instructies ConventionsConservez CES Informations Guarde Estas Instrucciones GEM Disse Anvisninger Xii Obtaining Documentation and Submitting a Service Request Xiv Overview Optional DVD module Rear Panel Features Feature or Component Cisco UCS C200 Server LFF RAID = redundant array of independent disks Installing the Server Unpacking and Inspecting the Server Shipping Box ContentsInstallation Guidelines Preparing for InstallationRequired Equipment Slide Rail Adjustment RangeRack Requirements Installing the Server Into a Rack Attaching a Slide-Rail Assembly Attaching Mounting Brackets to the Server Attaching the Cable Management Arm Connecting and Powering On the Server Standalone Mode Initial Server SetupOL-20732-02 Cisco UCS C200 Server Installation and Service Guide NIC Modes and NIC Redundancy Settings Updating the Bios and Cimc Firmware System Bios and Cimc FirmwareAccessing the System Bios Motherboard Jumpers Service Jumper LocationsUsing the Bios Recovery Jumper J1E5 to Recover Corrupt Bios Clearing the Cimc Admin Password Using Jumper J45 Using the Clear Cmos Jumper J1E6 Clearing the Bios Admin Password Using Jumper J1E4 OL-20732-02 Cisco Integrated Management Interface Cimc Server Configuration UtilityServer Monitoring and Management Tools Front Panel LEDs Status LEDsLED Name State Rear Panel LEDs CPU fault Off-All CPUs are operating properlyLED Name State LED Name State Shutting Down and Powering Off the Server Preparing for Component InstallationRemoving and Replacing the Server in a Rack Removing the Top Cover of the Server Removing and Replacing the Server Top CoverRemoving the Front Cover of the Server 6shows the Large Form Factor LFF version of the server Replaceable Component LocationsReplaceable Component Locations, Small Form Factor Top View Installing or Replacing Components Maintaining the Server Installing or Replacing Components 282338 Alternate Front Panel Module Cable Routing Installing Hard Drives or Solid State Drives HDD01 HDD02 HDD03 HDD04 HDD01 HDD02 HDD03 HDD04 HDD05 HDD06 HDD07 HDD08 PSU2 PSU1 Installing Power SuppliesInstalling a Fan Tray 15 Removing and Replacing a Fan Tray Memory Performance Guidelines and Population Rules Installing DIMMsMemory Population Rules Low-Voltage Dimm Considerations Generation M2 Only Dimm Installation Procedure 17 Removing and Replacing Memory Modules Installing CPUs and Heatsinks 18 Removing and Replacing CPUs and Heatsinks Installing a Motherboard Cmos Battery 19 Removing and Replacing a Motherboard Cmos Battery Installing a Trusted Platform ModuleTPM Replacing a PCIe Riser Card Assembly Replacing a PCIe Card 21 Removing and Replacing a PCIe Riser Card AssemblyReplacement Procedure PCIe Slot How to Identify Which Power Supply Model is in Your Server Resolving Insufficient Memory Space to Execute Option ROMs Resolving Insufficient 16-Bit I/O Space Replacing an LSIiBBU06 BBU Replacing an LSI MegaRAID Battery Backup Unit24 Removing and Replacing an LSIiBBU06 BBU 25 Replacing a Mounting Bracket for the LSIiBBU08 BBU Replacing an LSIiBBU08 BBUScrews 27 Removing and Replacing an LSIiBBU06 BBU Installing a Mezzanine Card Mezzanine card retaining posts three Physical Specifications Technical SpecificationsPower Specifications Environmental SpecificationsKVM Cable Cable and Power Cord SpecificationsDescription Feet Meters Illustration Supported Power Cords and PlugsThis section contains the AC power cord illustrations AC Power Cord IllustrationsCAB-9K10A-EU CAB-9K10A-SW CAB-N5K6A-NA CAB-9K12A-NA OL-20732-02 Supported RAID Controllers and Required Cables RAID Controller ConsiderationsR200-SASCBL3 RAID Controller Cabling Enabling the Mezzanine Card RAID Controller in the BiosCisco UCS C200 SFF Server Cabling How to Determine Which Controller Is in Your ServerCisco UCS C200 LFF Server Cabling How To Launch Option ROM-Based Controller Utilities From your For More Information OL-20732-02 Installation for Cisco UCS Integration OL-20732-02