Siemens ESM technical specifications OSM TP62

Page 19

Introduction

1.1.5OSM TP62

Possible Attachments

The OSM TP62 allows attachment of up to 6 DTEs or network segments with TP connectors. By coupling an OSM via ports 7 and 8 it is possible to create optical bus and ring structures. The OSM TP62 can be linked with other OSM TP62, OSM TP22, OSM ITP53, OSM ITP62, and OSM BC08 modules via the optical ports.

The OSM TP62 also has eight digital inputs. The states of the inputs are available in a management information base (MIB) and can be read using an SNMP get request. Depending on the configuration of the device, changes at these inputs can also trigger the sending of E-mails, SNMP traps and/or entries in the log of the OSM. The use of this function is described in the OSM/ESM Network Management User Manual /1/.

Figure 5: OSM TP62

Industrial Ethernet OSM/ESM

15

C79000-Z8976-C068-10

Image 19
Contents Simatic NET Copyright Siemens AG 2000/02, All rights reserved Classification of Safety-Related NoticesCorrect Usage of Hardware Products Safety Instructions Regarding your ProductTrademarks Qualified PersonnelPrior to Startup Correct Usage of Software ProductsPackage Installing an OSM/ESMPreface Purpose of the Operating InstructionsFurther Documentation Validity of the Operating InstructionsFinding Information Standards and Approvals Guide to the ManualAudience Personnel Qualification RequirementsContents Introduction Introduction OSM ITP62 Overview of the Variants of the OSM/ESMPossible Attachments Properties of the OSM ITP62 OSM ITP62-LD OSM ITP62-LDITP62-LD Properties of the OSM ITP62-LDOSM ITP53 OSM ITP53Properties of the OSM ITP53 ESM ITP80 ESM ITP80Properties of the ESM ITP80 OSM TP62 OSM TP62Properties of the OSM TP62 ESM TP80 ESM TP80Properties of the ESM TP80 OSM BC08 OSM BC08Properties of the OSM BC08 OSM TP22 OSM TP22Properties of the OSM TP22 ESM TP40 ESM TP40Properties of the ESM TP40 Increased Network Performance Simple Network Configuration and Network ExpansionLimitation of Errors to the Network Segment Affected FunctionsDeleting Addresses Setting the Transmission Rate, AutonegotiationPackets with the Vlan Priority Tag Functions Network Topologies with OSM/ESM Bus with OSM Bus StructureBus with ESMs Redundant Ring Structure with OSMs Redundant Ring StructureESM in RM mode Redundant Coupling of Network Segments OSM/ESM Simultaneous Standby and Redundancy Manager Operation Port Assignment in the Standby ModeReplacing the Standby Master During Operation OSM RM mode Compatibility Compatibility of OSM Version 2/ESM with OSM/ORM VersionRing with OSM Version 2 as Redundancy Manager Redundant Coupling of Rings Standby Master Slave OSM Coupling Network Segments OSM RM modeInterfaces, Displays and Operator Controls ITP Ports ITP/TP PortsTP Ports Auto Polarity Exchange Autonegotiation ModeProperties of the TP/ITP Ports Link ControlInterfaces, Displays and Operator Controls FO Ports Standby-Sync Port Pinout Serial InterfaceTerminal Block for the Power Supply and Signaling Contact Signaling Contact Power SupplyRM Mode additional OSM/ESM in the Standby Mode Input voltage must not exceed +30V DC or fall below -30V DC Digital InputsStby Standby green LED Fault red LEDDisplays and Operator Controls LED Display StatusRM Redundancy Manager green LED Display mode Meaning LED PowerFault Mask Display Port LEDsFull duplex Port LED DIP Switches Two-Pin DIP SwitchSelect/Set Button Installation, Commissioning, Cleaning Maintenance Unpacking, Checking the Consignment Do not install damaged componentsPreparations InstallationStandard Rail Mounting Installing the OSM on a DIN Standard RailRemoving from the Standard Rail Removing from a Standard RailInstallation on the S7-300 Rail Installation on a Simatic S7-300 RailInstallation in the 19 Cubicle Installation in Pairs in the 19 CubicleWall Mounting Wall MountingWall Mounting Cleaning Maintenance Specifying the keyword OSM Firmware Firmware UpdateFirmware Update Firmware Update Firmware Update Firmware Update Ports Technical SpecificationsTechnical Specifications Permitted Cable Lengths Switching Properties of OSM/ESMCascading Depth Permitted Only horizontal installationPermitted Ambient Conditions/EMC Mechanical DesignConsignment / Order Numbers Accessories Product name Standards and ApprovalsCE Mark CSA Certification Area of ApplicationApproval for Australia UL ApprovalFM Approval Adherence to Installation Instructions Glossary Fault Mask Filtering ITP PortLink Control LatencyTP Port Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 Http//www4.ad.siemens.de/view/cs/de/8677203 ReferencesIndustrial Ethernet OSM/ESM C79000-Z8976-C068-10 Ambient conditions, permitted IndexIndex