Siemens Permitted Cable Lengths, Cascading Depth, Switching Properties of OSM/ESM

Page 84

Technical Specifications

Permitted Cable Lengths

 

 

FO cable length between two OSMs

For OSM ITP62, OSM ITP53, OSM

 

TP62, OSM TP22:

 

0-3000 m (62.5/125 m glass fiber; 1

 

dB/km at 1300 nm; 600 MHz*km; 6 dB

 

max. permitted FO cable attenuation at 3

 

dB link power margin)

 

0-3000 m (50/125 m glass fiber; 1

 

dB/km at 1300 nm; 600 MHz*km; 6 dB

 

max. permitted FO cable attenuation at 3

 

dB link power margin)

 

For OSM ITP62-LD:

 

0-26000 m (10/125 m single mode

 

fiber; 0,5 dB/km at 1300 nm; 13 dB max.

 

permitted FO cable attenuation at 2 dB

 

link power margin)

ITP cable length

0-100 m

TP cable length

0-10 m with TP cord

 

up to 100 m total length when using the

 

FastConnect cabling system

Length of the ITP XP Standard Cable

0-40 m

9/9 at standby-sync port

 

 

 

 

 

Cascading Depth

 

 

Bus/star structure

Any (only depending on signal

 

propagation time)

Redundant ring

50 (for reconfiguration time < 0.3 s)

 

 

 

Switching Properties of OSM/ESM

 

 

Number of learnable addresses

 

Up to 7000

Aging time

 

40s (default)

Latency

 

4 s (measured at 75% load between

 

 

two ports operating at 100 Mbps)

Switching procedure

 

Store and forward

80

Industrial Ethernet OSM/ESM

C79000-Z8976-C068-10

Image 84
Contents Simatic NET Classification of Safety-Related Notices Copyright Siemens AG 2000/02, All rights reservedSafety Instructions Regarding your Product TrademarksQualified Personnel Correct Usage of Hardware ProductsCorrect Usage of Software Products Prior to StartupInstalling an OSM/ESM PrefacePurpose of the Operating Instructions PackageValidity of the Operating Instructions Further DocumentationFinding Information Guide to the Manual AudiencePersonnel Qualification Requirements Standards and ApprovalsContents Introduction Introduction Overview of the Variants of the OSM/ESM OSM ITP62Possible Attachments Properties of the OSM ITP62 OSM ITP62-LD OSM ITP62-LDProperties of the OSM ITP62-LD ITP62-LDOSM ITP53 OSM ITP53Properties of the OSM ITP53 ESM ITP80 ESM ITP80Properties of the ESM ITP80 OSM TP62 OSM TP62Properties of the OSM TP62 ESM TP80 ESM TP80Properties of the ESM TP80 OSM BC08 OSM BC08Properties of the OSM BC08 OSM TP22 OSM TP22Properties of the OSM TP22 ESM TP40 ESM TP40Properties of the ESM TP40 Simple Network Configuration and Network Expansion Limitation of Errors to the Network Segment AffectedFunctions Increased Network PerformanceSetting the Transmission Rate, Autonegotiation Deleting AddressesPackets with the Vlan Priority Tag Functions Network Topologies with OSM/ESM Bus Structure Bus with OSMBus with ESMs Redundant Ring Structure Redundant Ring Structure with OSMsESM in RM mode Redundant Coupling of Network Segments OSM/ESM Port Assignment in the Standby Mode Simultaneous Standby and Redundancy Manager OperationReplacing the Standby Master During Operation OSM RM mode Compatibility of OSM Version 2/ESM with OSM/ORM Version CompatibilityRing with OSM Version 2 as Redundancy Manager Redundant Coupling of Rings Standby Master Slave OSM Coupling Network Segments RM mode OSMInterfaces, Displays and Operator Controls ITP/TP Ports ITP PortsTP Ports Autonegotiation Mode Properties of the TP/ITP PortsLink Control Auto Polarity ExchangeInterfaces, Displays and Operator Controls FO Ports Standby-Sync Port Serial Interface PinoutTerminal Block for the Power Supply and Signaling Contact Power Supply Signaling ContactRM Mode additional OSM/ESM in the Standby Mode Digital Inputs Input voltage must not exceed +30V DC or fall below -30V DCFault red LED Displays and Operator ControlsLED Display Status Stby Standby green LEDRM Redundancy Manager green LED LED Power Display mode MeaningFault Mask Port LEDs DisplayFull duplex Port LED Two-Pin DIP Switch DIP SwitchesSelect/Set Button Installation, Commissioning, Cleaning Maintenance Do not install damaged components Unpacking, Checking the ConsignmentInstallation PreparationsInstalling the OSM on a DIN Standard Rail Standard Rail MountingRemoving from a Standard Rail Removing from the Standard RailInstallation on a Simatic S7-300 Rail Installation on the S7-300 RailInstallation in Pairs in the 19 Cubicle Installation in the 19 CubicleWall Mounting Wall MountingWall Mounting Cleaning Maintenance Firmware Update Specifying the keyword OSM FirmwareFirmware Update Firmware Update Firmware Update Firmware Update Technical Specifications PortsTechnical Specifications Switching Properties of OSM/ESM Permitted Cable LengthsCascading Depth Only horizontal installation Permitted Ambient Conditions/EMCMechanical Design PermittedConsignment / Order Numbers Accessories Standards and Approvals Product nameCE Mark Area of Application Approval for AustraliaUL Approval CSA CertificationFM Approval Adherence to Installation Instructions Fault Mask Filtering ITP Port GlossaryLatency Link ControlTP Port Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 References Http//www4.ad.siemens.de/view/cs/de/8677203Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 Index Ambient conditions, permittedIndex