The switching technology of the Industrial Ethernet OSM Version 2/ESM (Optical/Electrical Switching Module) allows the structuring of Ethernet networks with large spans and large numbers of nodes. It simplifies network configuration and network expansions. The OSM Version 2/ESM are simply called OSM/ESM in the rest of this manual.

The OSMs have both electrical ports and additional FO ports via which several of these devices can be interconnected to form an optical bus or ring configuration. ESMs only have electrical ports.

DTEs, other OSMs/ESMs or complete network segments operating at 10 or 100 Mbps can be connected to the electrical autonegotiation (autosensing) ports of the OSM/ESM. The transmission rate is detected automatically.

To increase availability, ring configurations can be created with OSMs or ESMs. To do this, OSMs or ESMs are first connected together to form a bus using their ring ports. The ends of the bus are closed to form a ring by an OSM or ESM operating in the Redundancy Manager mode (RM mode).

The OSM or ESM operating in the RM mode monitors the attached bus and allows a connection through it if it detects an interruption on the attached bus; in other words, it reestablishes a function bus. Reconfiguration is completed within 0.3s. An OSM/ESM is switched over to the RM mode using a DIP switch on the device.

The redundant standby coupling allows the redundant coupling of OSM/ESM or OLM rings. To do this, two OSM/ESMs (one operating in standby mode) are connected via their standby-sync ports.

With the ITP variants of the OSM/ESM, the DTEs are connected using sub-D female connectors. This connector technology allows direct links over distances up to 100 m. With the TP variants, the DTEs are connected using RJ-45 jacks.

The Version 2 OSMs are compatible with the previous OSM variants (6GK 1105- 0AA00) and ORM (6GK1105-1AA00) and can, for example, be mixed with these in an optical ring.

This manual describes the functions of the OSM/ESM available without using network management. The OSM/ESM Network Management user manual /1/ describes the additional options available if you use network management. You will find this manual on the CD accompanying every OSM/ESM or you can download the manual from the Web in Siemens Customer Support under entry number 8677203:

http://www4.ad.siemens.de/view/cs/de/8677203

6

Industrial Ethernet OSM/ESM

C79000-Z8976-C068-10

Image 10
Contents Simatic NET Classification of Safety-Related Notices Copyright Siemens AG 2000/02, All rights reservedQualified Personnel Safety Instructions Regarding your ProductTrademarks Correct Usage of Hardware ProductsCorrect Usage of Software Products Prior to StartupPurpose of the Operating Instructions Installing an OSM/ESMPreface PackageFurther Documentation Validity of the Operating InstructionsFinding Information Personnel Qualification Requirements Guide to the ManualAudience Standards and ApprovalsContents Introduction Introduction OSM ITP62 Overview of the Variants of the OSM/ESMPossible Attachments Properties of the OSM ITP62 OSM ITP62-LD OSM ITP62-LDProperties of the OSM ITP62-LD ITP62-LDOSM ITP53 OSM ITP53Properties of the OSM ITP53 ESM ITP80 ESM ITP80Properties of the ESM ITP80 OSM TP62 OSM TP62Properties of the OSM TP62 ESM TP80 ESM TP80Properties of the ESM TP80 OSM BC08 OSM BC08Properties of the OSM BC08 OSM TP22 OSM TP22Properties of the OSM TP22 ESM TP40 ESM TP40Properties of the ESM TP40 Functions Simple Network Configuration and Network ExpansionLimitation of Errors to the Network Segment Affected Increased Network PerformanceDeleting Addresses Setting the Transmission Rate, AutonegotiationPackets with the Vlan Priority Tag Functions Network Topologies with OSM/ESM Bus Structure Bus with OSMBus with ESMs Redundant Ring Structure Redundant Ring Structure with OSMsESM in RM mode Redundant Coupling of Network Segments OSM/ESM Simultaneous Standby and Redundancy Manager Operation Port Assignment in the Standby ModeReplacing the Standby Master During Operation OSM RM mode Compatibility of OSM Version 2/ESM with OSM/ORM Version CompatibilityRing with OSM Version 2 as Redundancy Manager Redundant Coupling of Rings Standby Master Slave OSM Coupling Network Segments RM mode OSMInterfaces, Displays and Operator Controls ITP Ports ITP/TP PortsTP Ports Link Control Autonegotiation ModeProperties of the TP/ITP Ports Auto Polarity ExchangeInterfaces, Displays and Operator Controls FO Ports Standby-Sync Port Serial Interface PinoutTerminal Block for the Power Supply and Signaling Contact Signaling Contact Power SupplyRM Mode additional OSM/ESM in the Standby Mode Digital Inputs Input voltage must not exceed +30V DC or fall below -30V DCLED Display Status Fault red LEDDisplays and Operator Controls Stby Standby green LEDRM Redundancy Manager green LED LED Power Display mode MeaningFault Mask Port LEDs DisplayFull duplex Port LED Two-Pin DIP Switch DIP SwitchesSelect/Set Button Installation, Commissioning, Cleaning Maintenance Do not install damaged components Unpacking, Checking the ConsignmentInstallation PreparationsInstalling the OSM on a DIN Standard Rail Standard Rail MountingRemoving from a Standard Rail Removing from the Standard RailInstallation on a Simatic S7-300 Rail Installation on the S7-300 RailInstallation in Pairs in the 19 Cubicle Installation in the 19 CubicleWall Mounting Wall MountingWall Mounting Cleaning Maintenance Firmware Update Specifying the keyword OSM FirmwareFirmware Update Firmware Update Firmware Update Firmware Update Technical Specifications PortsTechnical Specifications Permitted Cable Lengths Switching Properties of OSM/ESMCascading Depth Mechanical Design Only horizontal installationPermitted Ambient Conditions/EMC PermittedConsignment / Order Numbers Accessories Product name Standards and ApprovalsCE Mark UL Approval Area of ApplicationApproval for Australia CSA CertificationFM Approval Adherence to Installation Instructions Fault Mask Filtering ITP Port GlossaryLink Control LatencyTP Port Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 References Http//www4.ad.siemens.de/view/cs/de/8677203Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 Index Ambient conditions, permittedIndex