3M 1420EZ manual Miscellaneous Errors

Page 18

Miscellaneous Errors

ERROR: If an attempt is made to read or write to iD-Markers and the Dynatel1420EZ Writer is not powered on or the incorrect comport is selected, one or both of the following dialog boxes will appear:

REMEDY: Power On the Dynatel1420EZ Writer or verify that the correct comport is selected.

ERROR: If a unit other than the Dynatel1420EZ Writer is connected to the PC, the following error dialog box appears when the Read/Write tab is clicked in DynatelPCTools;

REMEDY: Connect the Dynatel1420EZ Writer unit to the PC.

ERROR: If the Dynatel1420EZ Writer is connected to the PC and the following error dialog box appears;

REMEDY 1: Verify serial cable connection between PC and Dynatel1420EZ Writer unit.

REMEDY 2: Verify Dynatel1420EZ Writer unit is powered on.

REMEDY 3: Verify correct comport has been selected.

REMEDY 4: Verify baud rate of 38,400 is selected.

18

78-9000-0120-3-A

Image 18
Contents 3M Dynatel 1420EZ Writer Contents Safety Information Intended UseDynatel 1420EZ Stand Assembly IntroductionInitial Set-up Dynatel 1420EZ Writer Battery Installation Dynatel 1420EZ Writer Keypad, Icon and Port DefinitionsClick the Initial Configuration button Dynatel 1420EZ Writer OperationCreating iD-Marker Templates using Dynatel PCTools Read/Write Tab Set-up in Dynatel PCToolsTemplate Section Writing iD-Markers Log Data SectionRead or Read/Write iD-Markers Read Only Button Read and Write Button Was Blank Marker Heading Written and verified Error and Warning Messages Low BatteryRead Failures 78-9000-0120-3-A Read and Write Failures Total Number of Markers in Fixture Error Miscellaneous Errors Specifications Dynatel 1420EZ WriterImportant Notice