3M 1420EZ manual Error and Warning Messages, Low Battery, Read Failures

Page 14

The Total Markers Written box shows the total count of all the iD-Markers that were read, written and verified successfully.

−−If this count matches the Total Markers Read box value, then it is highlighted in green.

−−If the count does not match, then it is highlighted in red.

Error and Warning Messages

Low Battery

ERROR: If the battery level of the Dynatel1420EZ Writer is too low to allow reading or writing of iD- Markers, a warning dialog box is displayed. The battery level verification occurs every time the Read Only or Read and Write button is clicked. The following dialog box is displayed prompting the user to change batteries;

REMEDY: Replace all eight (8) AA alkaline batteries in the Dynatel1420EZ Writer.

Read Failures

Three different read errors are possible:

ERROR 1: Low Signal Level: If the signal level is too low to write to a marker, then is displayed in the Signal Level column. When the magnifying glass icon is clicked, the actual signal level at which the marker is read is displayed.

REMEDY 1: Reread iD-Marker. If it fails again, remove it from the Dynatel1420EZ Stand and replace with a different iD-Marker.

REMEDY 2: Relocate the Dynatel1420 EZ Writer to another location and retry. Ambient noise in the room may be too high.

ERROR 2: Data Errors: If there are data errors,is displayed in the Data Errors column.

REMEDY: Reread iD-Marker. If it fails again, remove it from the Dynatel1420EZ Stand and replace with a different iD-Marker.

14

78-9000-0120-3-A

Image 14
Contents 3M Dynatel 1420EZ Writer Contents Safety Information Intended UseInitial Set-up Dynatel 1420EZ Stand AssemblyIntroduction Dynatel 1420EZ Writer Battery Installation Dynatel 1420EZ Writer Keypad, Icon and Port DefinitionsClick the Initial Configuration button Dynatel 1420EZ Writer OperationCreating iD-Marker Templates using Dynatel PCTools Read/Write Tab Set-up in Dynatel PCToolsTemplate Section Writing iD-Markers Log Data SectionRead or Read/Write iD-Markers Read Only Button Read and Write Button Was Blank Marker Heading Written and verified Read Failures Error and Warning MessagesLow Battery 78-9000-0120-3-A Read and Write Failures Total Number of Markers in Fixture Error Miscellaneous Errors Specifications Dynatel 1420EZ WriterImportant Notice