Allied Telesis AT-CV5000 manual CPU Reset, Button LEDs

Page 26

Chapter 1: Overview

CPU RESET

Button

LEDs

end node with a fixed duplex mode of full-duplex to a management card port, you should use the AT-S70 management software to disable Auto-Negotiation on the port and set the port speed and duplex mode manually.

For 10 Mbps operation, Category 3 or better, 100 Ohm shielded or unshielded, twisted pair cabling is required. For 100 Mbps operation, Category 5 or Enhanced Category 5 (5E), 100 Ohm shielded or unshielded, twisted pair cabling is required.

The recessed CPU RESET button allows you to reset only the management card. You may need to reset the management card after upgrading the firmware or after you have made a configuration change that requires resetting the module to activate the change.

Note

This reset button does not reset the line cards and/or the module installed in the expansion slot at the rear of the chassis.

The status LEDs located on the AT-CV5M01 Management Card are described in Table 2.

Table 2. Status LEDs on the AT-CV5M01 Management Card

LED

State

Description

 

 

 

 

 

 

PWR

Green

The management card is receiving power.

 

 

 

 

OFF

The management card is not receiving

 

 

power if this LED is off for more than 10

 

 

seconds.

 

 

 

RDY

Green

The management card has passed

 

 

diagnostics and is ready.

 

 

 

 

OFF

The management card has failed

 

 

diagnostics and is not ready.

 

 

 

FLT

Green

The management card has a fault condition.

 

 

 

 

OFF

The management card has not reported a

 

 

fault condition.

 

 

 

LK

Green

Link established on the twisted pair port.

 

 

 

 

OFF

No link established on the twisted pair port.

 

 

 

AT

Blinking Green

TX/RX activity detected on the twisted pair

 

 

port.

 

 

 

 

OFF

No activity detected on the twisted pair port.

 

 

 

26

Image 26
Contents Installation Guide Page Electrical Safety and Emissions Standards Translated Safety Statements Contents Physical Specifications AT-CV5000 Media Converter Chassis Installation Guide Contents Figures Figures Tightening the Captive Screw Tables Tables Preface Safety Symbols Used in this Document Symbol Meaning DescriptionWhere to Find Web-based Guides Management Software Updates Contacting Allied TelesisOverview ChapterAT-CV5000 Overview AT-CV5000Hardware Features Software Features System DescriptionReset Button Front and Rear Panel ComponentsLED Interface Card Interface Card LEDs Reset LINE/ EXP Button AT-CV5M01 Management Card 10/100Base-TX Twisted Pair Port CPU Reset Button LEDsGreen Twisted pair port is operating in full Duplex mode Converteon Line Cards Link Test MissingLinkSmart MissingLink Line Card Port DescriptionsBlank Slot Covers Illustrates the AT-CV5PNLx Series blank slot coversPower Supplies Rear EXP. SlotFan Modules 201Management Connections MAC Address Table Duplex Mode Few Basics about Media ConvertersPass-through Network Topologies Standalone TopologyBack-to-Back Network Topology Overview Installation Reviewing Safety Precautions AT-CV5000 Media Converter Chassis Installation Guide Installation AT-CV5000 Media Converter Chassis Installation Guide Selecting a Site for the Chassis Unpacking the Chassis Inserting the Retaining Clip into the Retaining Bracket Retaining Clip Properly Installed in the Bracket Installing the AT-CV5000 Chassis in a Rack 236AT-CV5000 Media Converter Chassis Installation Guide Frame Ground Connectors Grounding the AT-CV5000 ChassisFrame ground stud for power supply a is shown in Figure Installing a Converteon Line Card Inserting a Line Card 249 Cabling a Converteon Line Card in an AT-CV5000 Chassis Cabling a Fiber Optic PortFiber Connector Cabling a Simplex SC Connector Cabling an SFP Transceiver Connecting Fiber Optic Cables to the SFP Transceiver Powering On an AC Powered Chassis VAC ~PWR a PWR B PWR a AT-CV5000 Media Converter Chassis Installation Guide Powering On a DC Powered Chassis DC Terminal Block8mm ±1mm 31in. ±0.039in 256 Connecting a Management Cable to the RS-232 Console Port Starting a Local Management SessionAT-S70 Main Menu AT-CV5000 Media Converter Chassis Installation Guide Starting a Remote Management Session Guideˆ Usernames and passwords are case-sensitive Installation Working with Line Cards and other Modules Removing a Converteon Line Card AT-CV5000 Media Converter Chassis Installation Guide Management Card Installing anWorking with the AT-CV5M01 Management Card Resetting an Replacing an Installing an AT-CM70S Line Card 907 Resetting Converteon Line Cards/Rear Expansion Module Installing an AT-PWR14 AC Power Supply AT-PWR14 Installing an AT-PWR15 DC Power Supply AT-PWR15 Replacing an AT-CVFAN Module Removing an AT-CVFAN Module from Fan Slot a Tightening the Screws on the AT-CVFAN Module in Slot a AT-CV5PWRAC Installing a Blank Slot Cover Blank Slot CoverAT-CM202 AT-CV5PNL2 AT-CV5PNL3 AT-PWR14 Troubleshooting Troubleshooting PWR LED is RDY LED is Blinking RDY LED is OFF FLT LED isFLT LED is Steadily on LK LED is OFF LK LED is Blinking LK LED is OFFAT-CV5000 Media Converter Chassis Installation Guide Troubleshooting 100 Power Specifications Physical SpecificationsEnvironmental Specifications Appendix aSafety and Electromagnetic Emissions Certifications StandardsPin Signal RJ-45 Twisted Pair Port PinoutsRS-232 Terminal Port Pinouts Illustrates the pin layout to an RS-232 terminal portPin Mini-DIN Console Port Pinouts SC Type Connectors Dual SC Connector Simplex SC ConnectorDual ST Type Connector Cable Dual ST Connector CableSFP Transceiver Cable SFP Transceiver CableCleaning Fiber Optic Connectors Appendix BUsing a Cartridge-Type Cleaner 111 Using a Swab Cleaning a Recessed Ferrule If desired, repeat step113 Appendix B Cleaning Fiber Optic Connectors 114