Chapter 2: Installation
Powering On a DC Powered Chassis
This section describes how to power on a DC powered
Warning: As a safety precaution, install a circuit breaker with a minimum value of 15 Amps between the equipment and the DC power source.
Always connect the wires to the LAN equipment first before you connect the wires to the circuit breaker. Do not work with HOT feeds to avoid the danger of physical injury from electrical shock. Always be sure that the circuit breaker is in the OFF position before connecting the wires to the breaker. E9
Warning: For centralized DC power connection, install only in a restricted access area. E23
A tray cable is required to connect the power source if the unit is powered by centralized DC power. The tray cable must be a UL listed Type TC tray cable and rated at 600 V and 90 degrees C, with three conductors, minimum 14 AWG. E24
1.Make sure that the ON/OFF power switch is in the OFF position.
2.Locate the two DC terminal blocks, labeled A and B, on the rear panel of the chassis.
3.Starting from the left side of a terminal block, identify the positive, power supply ground and negative terminals using the symbols below the terminal block in Figure 41.