MultiModemISDN User Guide

S-Register:

S5

Function:

Backspace Character

Unit:

Decimal ASCII code

Range:

0–32, 127

Default:

8 (^H)

Description: Specifies the character used by the TA to delete the previous character in the

 

command line.

S-Register:

S7

Function:

Wait for Connection (Abort Timer)

Unit:

1 second

Range:

0–255

Default:

45

Description: Sets the Abort Timer delay time, which is the length of time the TA waits for a

 

connection after dialing. If no connection is established during the specified

 

time, the TA ends the call.

S-Register:

S8

Function:

Pause Time for Comma

Unit:

1 second

Range:

n=0-255

Default:

2 (2 seconds)

Description: S8 sets the length of the pause caused by a comma inserted in a dialing

 

command. The default setting is 2 seconds, where each unit is one second.

 

S8 may be set for up to 255 seconds.

S-Register: S10

Function:

DCD Drop Time

Unit:

50 ms

Range:

0–254, 255

Default:

20

Description:Sets the time after a carrier signal is lost before the TA disconnects. (The

 

&C2 command must be in effect.) Default setting is one second. Maximum

 

delay is 25.4 seconds (S10=254). Set S10 to 255 to cause the TA not to

 

disconnect with loss of carrier.

S-Register: S25

Function:

DTR Drop Time

Unit:

100 ms

Range:

0, 1–255

Default:

5

Description: Sets the time that DTR must remain low before TA disconnects. The S25 unit value for 0 is 50 ms. For values from 1 through 255, the unit value is 100 ms.

58

Image 58
Contents User Guide User Guide Contents Troubleshooting Introduction and Description Universal Serial Bus USB IntroductionProduct Description MultiModemISDN User GuideManual Organization Introduction and DescriptionFeatures Technical Specifications LED IndicatorsHardware Installation Hardware Installation Safety Warning Telecom/ISDN-STUnpacking Your MTA128ST-USB Assembling the MTA128ST-USB Connecting the MTA128ST-USB to Your SystemMultiModem Isdn User Guide Connecting to Your Isdn Network Terminator Connecting to Your ComputerConnecting to Power Connecting to Analog EquipmentLED Indicators Hardware Installation Data Protocol ReferencesSoftware Installation and Configuration Software Installation and Configuration Installing in WindowsInstall Hardware Device Drivers dialog box displays If the Digital Signature Not Found dialog box displays Page Changing the Modem Descriptor Windows Upgrade Device Driver Wizard dialog box displaysMTA128ST-USB CDC ML-PPP Properties dialog box displays Start Device Driver Installation dialog box displays Installing in Windows Software Installation and Configuration MultiModemISDN User Guide Update Device Driver Wizard dialog box displays MTA128ST-USB ML-PPP Properties dialog box displaysUpgrade Device Driver Wizard dialog box displays Software Installation and Configuration Click Start Settings Control Panel Removing Your Old Device from Windows 2000 and Windows 98Configuration Network ConfigurationAT commands AT!C6= and AT*!C6= Call Control ConfigurationAT commands AT!N1= and AT*!N1= Dialing Stored Numbers Isdn MTA128ST-USB Configuration Utility To Install in Windows 2000/98/95Windows 2000 Dial-Up Networking MultiModemISDN User Guide If you select Accept incoming connections MultiModemISDN User Guide Windows 98/95 Dial-Up Networking MultiModemISDN User Guide AT Commands Using AT Commands to Configure the MTA128ST-USBAT Commands, S-Registers and Result Codes Entering AT Commands AT Commands, S-Registers, and Result CodesAT Commands by Function Command ImplementationData Call Commands A97=1 A97=nA97=0 C0=2 Net3D3=241 D3=0-63D3=240 DN=1EN=2 EN=nEN=1 D98RXGn N2=nRXG10 =12 L5 and L6Connect String normally it is issued by itself ATZ E13 E4, &E6, &E13E12 #X0MultiModemISDN User Guide ROM $DnData Call Commands Command DSn Registers Register SummaryAT Commands, S-Registers, and Result Codes MultiModemISDN User Guide S31 S30S34 S49 S44S45 S50Ring S51S17 S53S54 S18AT Commands, S-Registers, and Result Codes S58 S59S61 S60S62 S64 S63S65 S67 S68S71 S69S70 S73S76 S75S77 S80 Result Codes Modes of Operation Using AT Commands to Operate the MTA128ST-USBMaking a Call DialingAnswering a Call Hanging Up Troubleshooting None of the LEDs light when the MTA128ST-USB is on Troubleshooting MTA128ST-USB dials but cannot make a connectionYou can place data calls but not voice calls or vice versa MTA128ST-USB disconnects while online MultiModemISDN User Guide Warranty, Service, and Technical Support Addendum for North American Products Limited WarrantyAddendum for International Products Warranty, Service and Tech Support Out of Warranty Repair Costs On-line Warranty RegistrationSoftware User License Agreement MultiModem Isdn User Guide Technical Support ServiceContacting Technical Support Ordering Accessories Using FlashWizard to Upgrade Firmware Upgrading the MTA128ST-USB with FlashWizardAppendixes Class B Statement FCC Part EMC, Safety, and Terminal Directive ComplianceAppendix a Regulatory Compliance Industry CanadaQuick Setup Example MultiVOIP 200 User GuideProfile 1 &F1 V.110 Asynchronous Operation Profile 2 &F2 V.120 Asynchronous Operation Profile 4 &F4 ML-PPP Asynchronous Operation Glossary Symbol GlossaryMultiModemISDN User Guide Glossary MultiModemISDN User Guide Glossary 100 101 TA- See terminal adapter102 103 Index Index 10542, 52 106Isdn MTA128ST-USB Config utility 107Rings 108