Chapter 4 - AT Commands, S-Registers, and Result Codes
3Austria
4Belgium
5Cyprus
6Denmark
7Finland
8France
9Germany 1
10Germany 2
11Greece
12Iceland
13Ireland
14Italy
15Luxembourg 1
16Luxembourg 2
17Malta
18Netherlands
19Norway
20Portugal
21Spain
22Sweden
23Switzerland 1
24Switzerland 2
25United Kingdom 1
26United Kingdom 2
27United States
Default: 0 (25 Hz, single ring, 2 sec. on, 4 sec. off)
Description: Sets the frequencies and cadences used when ringing the device attached to
| the POTS port (phone, modem, fax). Select the appropriate country to use |
| the frequencies and cadences specified according to ETS 300 001 (Chapter |
| 1:1992, p. 56). The Austria and France settings default the frequency to 25 |
| Hz since the TA doesn’t support a 50 Hz nominal frequency. A number 1 or 2 |
| next to a country name indicates the availability of either alternate nominal |
| frequencies or alternate cadences. You also can configure frequencies and |
| cadences by using @CONFIG menu (selection #6— POTS Port |
| Configuration) and/or with |
| Save configurations with the &W or &W0 command. |
S67 | |
Function: | Single or Dual Cadence Ring Signal |
Unit: | Decimal ASCII code |
Range: | 0 (Single), 1 (Dual) |
Default: | 0 |
Description: Sets the POTS port ring signal for single or dual cadence. Examples of a
| dual cadence include Ireland (S66=13), United Kingdom 1 (S66=25), and |
| United Kingdom 2 (S66=26). |
S68 | |
Function: | First Active Duration |
Unit: | 1 ms |
Range: | |
Default: | 2000 ms |
67