■REAR TERMINAL SETTINGS
♦MODE OUT 1 ~ MODE OUT 5
The unit status can be outputted from the MODE OUT termi- nals on the rear. There are 5 MODE OUT terminals and each terminal can be set to generate a certain type of output.
<REAR | TERMINAL SETTINGS> | OFF | ||
>>MODE | OUT | 1 |
| |
MODE | OUT | 2 |
| OFF |
MODE | OUT | 3 |
| OFF |
MODE | OUT | 4 |
| OFF |
MODE | OUT | 5 |
| OFF |
KEY SOUND |
|
| ON | |
BUZZER |
|
| OFF | |
REMAIN HDD | ||||
CALL OUT SETTINGS |
| 10M | ||
EMERGENCY REC DURATION |
Setting ( default : “OFF” )
“REC” : Outputs signals during recording.
“PLAY” : Outputs signals during playback.
“REMAIN” : Outputs signals when the remaining HDD device space reaches the value specified in “REMAIN HDD”.
“POWER” : Outputs signals when the power of the unit turns on.
“MOTION1” ~ “MOTION4” : Outputs the camera num- bers detected during motion detection recording using binary notation (MODE OUT 1 ~ MODE OUT 4 are linked). Furthermore, motion detection inputted the last is maintained for 2 seconds.
Relation between a camera number and a MODE OUT output
| MODE OUT terminals |
| |||
| 1 | 2 | 3 | 4 |
|
1 | O | X | X | X |
|
2 | X | O | X | X |
|
3 | O | O | X | X |
|
4 | X | X | O | X |
|
5 | O | X | O | X |
|
6 | X | O | O | X |
|
7 | O | O | O | X | O : Signal is outputted. |
8 | X | X | X | O | |
9 | O | X | X | O | X : No signal is outputted. |
“ALARM” : Outputs signals during alarm recording.
“LAN” : It is the MODE OUT terminal controllable from a communication function’s.
“OFF” : No signal is outputted.
Capacity warning from MODE OUT is only outputted during recording.
1.Press the SET UP button } <SETTINGS> } <INITIAL SET UP/INFORMATION> } Select “REAR TERMINAL SETTINGS” screen.
2.From the 5 MODE OUT terminals, display the desired setting for the terminal (MODE OUT 1 ~ MODE OUT 5) to output signals and then confirm.
3.To set other terminals, repeat step 2.
4.Turn the SHUTTLE ring counterclockwise or press the SET UP button.
♦KEY SOUND
It is possible for the unit to make button sounds when using the operation buttons on the front of the unit or when operating the JOG dial or SHUTTLE ring.
<REAR | TERMINAL SETTINGS> | OFF | ||
MODE | OUT | 1 |
| |
MODE | OUT | 2 |
| OFF |
MODE | OUT | 3 |
| OFF |
MODE | OUT | 4 |
| OFF |
MODE | OUT | 5 |
| OFF |
>>KEY SOUND |
|
| ON | |
BUZZER |
|
| OFF | |
REMAIN HDD | ||||
CALL OUT SETTINGS |
| 10M | ||
EMERGENCY REC DURATION |
1.Press the SET UP button } <SETTINGS> } <INITIAL SET UP/INFORMATION> } Select “KEY SOUND” in the <REAR TERMINAL SETTINGS> screen. Display the desired setting and confirm.
2.Turn the SHUTTLE ring counterclockwise or press the SET UP button.
♦BUZZER
It is possible for a buzzer to sound when the remaining HDD device space reaches the value set in “REMAIN HDD” of the <REAR TERMINAL SETTINGS> screen. Other than the above, it is possible to set the buzzer to sound when starting alarm recording or emergency recording, or when a warning is displayed.
<REAR | TERMINAL SETTINGS> | OFF | ||
MODE | OUT | 1 |
| |
MODE | OUT | 2 |
| OFF |
MODE | OUT | 3 |
| OFF |
MODE | OUT | 4 |
| OFF |
MODE | OUT | 5 |
| OFF |
KEY SOUND |
|
| ON | |
>>BUZZER |
|
| OFF | |
REMAIN HDD | ||||
CALL OUT SETTINGS |
| 10M | ||
EMERGENCY REC DURATION |
To sound a buzzer only when reaching a specified value :
1)Select “REMAIN” for “BUZZER” in the <REAR TER- MINAL SETTINGS> screen.
2)Set the remaining capacity in “REMAIN HDD” of the <REAR TERMINAL SETTINGS> screen.
To sound a buzzer when reaching the set remaining ca- pacity or when a warning is displayed :
1)Select “WARNING” for “BUZZER” in the <REAR TER- MINAL SETTINGS> screen.
2)Set the remaining HDD capacity (HDD MAIN RE- MAIN/HDD SUB REMAIN) in “CALL OUT SETTINGS” of the <REAR TERMINAL SETTINGS> screen.
ENGLISH |
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• | Operations |
49