Mitsubishi Electronics DX-TL950E Operation examples, Following day, REC Mode C screen setting see

Page 62

Operation examples (continued)

7)<TIMER PROGRAM> screen setting ( see pages 44,45 ).

PROGRAM NO.1 : “SPL”, “08:00”, “15:00”, “A”, “OFF”.

PROGRAM NO.2 : “SPL”, “15:00”, “20:00”, “B”, “OFF”.

PROGRAM NO.3 : “SAT”, “08:00”, “17:00”, “B”, “OFF”.

PROGRAM NO.4 : “SUN”, “08:00”, “17:00”, “B”, “OFF”.

PROGRAM NO.5 : “HOL”, “08:00”, “17:00”, “B”, “OFF”.

SPL : “MON - FRI”.

<TIMER PROGRAM>

 

P2

1

DW

START END MODE

MD

SPL

08:00 15:00 A

OFF

2

SPL

15:00 20:00 B

OFF

3

SAT

08:00 17:00 B

OFF

4

SUN

08:00 17:00 B

OFF

5

HOL

08:00 17:00 B

OFF

6

---

--:-- --

:-- ----

-

7

---

--:-- --

:-- ----

-

8

---

--:-- --

:-- ----

-

>>SPL

MON-FRI

 

 

When completed with all settings above and after clear- ing the menu screen, press the TIMER button. The unit will switch to the timer mode.

Operation example 3

This example illustrates the procedure for using Pre-alarm recording, Alarm recording, Emergency recording with nor- mal recording in Timer record mode.

< Operation >

REC MODE C (pre-alarm recording, alarm recording and emergency recording with all cameras) is set to Monday ~ Friday from 08:00 to 15:00 and REC MODE D (pre-alarm recording, alarm recording and emergency recording with

camera number “1 ”, “2 ”, “3 ”, “7 ”, “8 ” and “9 ”) is set to 15:00 ~ 08:00 of the following day.

On weekends, REC MODE D (pre-alarm recording, alarm recording and emergency recording with camera number

1 ”, “2 ”, “3

”, “7 ”, “8 ” and “9

” ) is set to 08:00 ~

08:00 of the following day.

 

 

 

 

 

 

 

 

 

 

15:00

Next day

08:00

 

08:00

 

From Monday

 

 

 

 

 

 

 

 

 

REC MODE C

 

REC MODE D

 

to Friday

 

 

 

 

 

 

 

 

 

 

 

 

 

08:00

 

 

 

Next day

 

 

 

08:00

 

 

 

 

 

 

 

 

 

Saturday and

 

 

REC MODE D

 

Sunday

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

< Setting >

1)Set 1) ~ 3) of “Operation example “1 ” previous.

2)<REAR TERMINAL SETTINGS> screen setting ( see page 51).

EMERGENCY REC DURATION : “20M”.

<REAR

TERMINAL SETTINGS>

OFF

MODE

OUT

1

 

MODE

OUT

2

 

OFF

MODE

OUT

3

 

OFF

MODE

OUT

4

 

OFF

MODE

OUT

5

 

OFF

KEY SOUND

 

 

ON

BUZZER

 

 

OFF

REMAIN HDD

MAIN-10%

CALL OUT SETTINGS

 

20M

>>EMERGENCY REC DURATION

 

 

 

 

 

3)Set each item in the <MOTION DETECTION SET-

TINGS> screen for all cameras ( see pages 39,40).

<MOTION DETECTION

SETTINGS>

 

>>SELECTION CAMERA

NO.

1

DETECTION MASK SETTING

 

SENSITIVITY

HIGH••<<<LOW

MOTION THRESHOLD

 

5

TEST MODE

 

 

4)<TIMER PROGRAM SETTINGS> screen setting ( see pages 44-46).

SELECTED PATTERN : “P3”.

ALARM REC DURATION : “5M”.

<TIMER PROGRAM SETTINGS>

P3-SET

SELECTED PATTERN

HOLIDAY SETTING

 

REC MODE A

 

REC MODE B

 

REC MODE C

 

REC MODE D

5M

>>ALARM REC DURATION

5)<REC MODE C> screen setting ( see page 46).

MOTION DET REC : “ALARM”

PRE ALARM REC : Set desired pre-alaem recording time.

<REC MODE C>

 

 

ALARM SETTING

 

 

RECORD SETTING

( S )

S

PRE ALARM REC

>>MOTION DET REC

 

ALARM

6)<ALARM SETTING C> screen setting ( see page

All cameras ( “ 1 ” ~ “ 9 ” ).

TRIGGER : MD/EXT.

EMR : All cameras ( “ 1 ” ~ “ 9 ” ) is setting.

<ALARM SETTING C>

<ALARM SETTING C> ALARM CH

ALARM

RECORD CAMERA

TRIGGER

1

1 --------

MD/EXT

2

-2-------

MD/EXT

3

-- 3 ------

MD/EXT

4

---4-----

MD/EXT

5

----5----

MD/EXT

6

-----6---

MD/EXT

7

------ 7 --

MD/EXT

8

------- 8 -

MD/EXT

>>9

-------- 9

MD/EXT

EMR

1 2 3 4 5 6 7 8 9

 

7)<RECORD SETTING C> screen setting ( see page

Camera selection during alarm recording : “ALARM CH”.

All cameras ( “ 1 ” ~ “ 9 ” ).

PPS, GRADE, A-PPS, A-GRADE : Set desired interval and picture quality for each camera.

When “0S” is selected, the pre-alarm recording is inoperable.

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

•••••••••••••

62

Image 62
Contents DX-TL950E Recording FeaturesBuilt-in duplex 9 channel multiplexer NetworkEase of use Auto set-upProtect the Power Cord When not in use always turn OFF the Main switchMains Lead Connection Contents 67-71 60-6365,66 72,73Auto SET UP FlowchartFlowchart for connection and settings Setting the timer recording Setting other various functionsSetting the motion detection Timer recording is executed/completedMajor operations and their functions Analogue OUT connectors Emergency indicatorLock indicator Front View Inside of the doorMajor operations and their functions Alarm Interrupt buttonSET UP button Search buttonCamera in connectors Main switchVideo OUT connectors Camera OUT connectorsRS-232C connector Ethernet connectorConnecting to Cctv camera, monitor, sensor ConnectionsConnections Alarm Recording ConnectionConnecting with analog video recorder Auto SET UP Turn the Shuttle ring clockwiseWhen the setting is complete, press the Power button Auto SET UP / Initial settingsHDD Setting InitializationMultiplexer functions Menu settingsBasic Operations Time Date Adjust Daylight SAVING/DAYLIGHT SettingDefault SUN, LAST, MAR Basic OperationsRecorded capacity display function Basic manual recordingPresent time display Long SUPER, HIGH, STDSTANDARD, BASIC, LongShort To change HDD or Compact Flash Card playback device Basic playbackBack repeatedly see HDD Repeat PLAY, Press the Play buttonTo pause playback, press the Pause button Basic searchTime Date Search To stop playback, press the Stop buttonEnglish , Francais , Deutsch For playback, see Various playback func- tions, pages 65,66Language Selection Españ OL, PyCCKNN, ItalianoMain Menu Menu SettingMenu functions SUB MenuSET UP Initial SET UP/INFORMATION HDD Settings Menu functionsMain Menu SUB Menu REC/STOP + Power button Copy Menu Search Selection MenuCamera TITLE/MEMO Setting Time Date AdjustDisplay Mode Clock Location SettingRepeat steps 2 ~ 6 to input Counter in the camera number Camera TITLE/MEMO Setting screen appearsDisplay returns to the Camera TITLE/MEMO Setting screen Appears in reversed color on the very left of the stringDuplex Mode Display Setting default BottomSPLIT/SEQUENCE button operations Plexer can also be found on seeCamera number button operations Available modesMPX Display Settings ZoomSPLIT9 Screen Setting MPX Display SettingsSPLIT4 Screen Setting For the SPLIT9 Screen SETTING, SPLIT9 screen can be set3 , 4 , 5 , 6 , 7 Sequence SettingInterlace Selection Camera Number Detection Mask SettingSetting default 3 , 4 , 5 , 6 , 7 , 8 Nected camera, are setSensitivity Motion Detection SettingsTest Mode Motion ThresholdWhen setting the camera selection during alarm recording Settings concerning normal recording and alarm recordingIng pre-alarm recording, see Alarm SettingPicture quality for normal recording pages 22,23 Record SettingsAbout alarm recording Recording time during alarm recording can be set Alarm REC DurationPRE Alarm REC Pre-alarm recording can be setStructure of the Timer Program screen Timer Program SettingsTimer Program Press the Timer button Cerning recording mode settings, see pages 22,23 Timer Program SettingsHoliday Setting Overlapping Timer settingsHDD Repeat Play HDD Settings HDD Repeat REC MAIN/HDD Repeat REC SUBSetting default OFF IM-CHECK PlayAudio Recording Initial SET UP/INFORMATIONSequential Play Single screen sequential playback startsBuzzer Rear Terminal Settings Mode OUT 1 ~ Mode OUTKEY Sound Call OUT Settings Setting of Device default MainSetting of Remain HDD default 10% Remain HDDHDD Main FULL/HDD SUB Full Communication Port SettingsRS-232C Emergency REC DurationMail Address SettingsEthernet Service Port Setting Alarm Notification SettingINFORMATION/SERVICE 2/2 INFORMATION/SERVICEINFORMATION/SERVICE 1/2 Setting is confirmed and stops flashingData Clear Reset to Factory Settings Menu screen settings are resetMenu screen settings are reset Simple Lock PasswordPassword Lock To unlock the Password for level Press the SET UP button To unlock the PasswordInput the Password entered in First in Second Repeat steps 2-2 ~ 2-4 to set level 2 and levelTo change the Password Changing from Password Lock mode to Simple Lock modeTo lock the Password only level1 to level Press the Warning Reset buttonTo save menu settings of this unit to a Compact Flash Card Quick SettingsTo update menu settings of this unit Quick Settings screen appearsOperation example SettingOperation examples OperationHoliday Setting 31/12, 01/01, 02/01, 03/01 This example uses the holiday settingHDD Settings screen setting see pages 47,48 Camera number 1 ~ Input titleRecord Setting C screen setting see REC Mode C screen setting seeAlarm Setting C screen setting see Operation examplesRecord Setting C REC Mode D screen setting seeRecord Setting D screen setting see Alarm Setting DVarious recordings PRE Alarm RecordingsPre-alarm recording Emergency RecordingsVarious playback functions Simultaneous playback during recording Press the REV. Play Reverse Playback buttonTime Date Search Various searchSearch Selection Press the Search button Index SEARCH/ALARM Index SearchVarious search Playback the search resultTo clear the search screen, press the Search button twice Alarm Skip SearchAlarm Skip Search In the case of forward direction Alarm List Search To clear the alarm list, erase the dataSearch screen selected in previous Search Type appears START/END SearchPress either the Play REV. Play or Pause button An end. Be careful Making Copy/RestoreMenu changes to Restore when CFC Main HDD is selected Video Cord Audio Cord Copying from unit to videotapeBack see Sequential PLAY, Analogue Video Cassette RecorderHDD Setting Power failure compensation circuitPower failure reset recording Other convenient functionsPartition Size setting appears on the Initialization screen Points to be aware of regarding Mirror modePoints to be aware of regarding Partition mode PARTITION/PARTITION SizeCovert Camera Setting screen appears Covert Camera SettingAlarm Display Other convenient functionsCommunications by Web Browser AuthenticationCommunications by Web Browser Personal computer product requirementsLive monitor Communications by Web BrowserWelcome Stop PlaybackTime Search Alarm SearchUser maintenance Select the date and time and click SearchChange log in user Covert Camera SettingLog out Logged in user is changed and the Welcome screen appears HDD continuous recording time for 250GB drive Recording time tableContinuous recording time table Without Audio recordingRecording time table Compact Flash Card continuous recording time for 64MBTroubleshooting Description of problem Please consult the followingTroubleshooting Detection Mask Setting ?Main Image Modified Glossary GlossaryGND SpecificationsConnectors Call OUT/CALL OUT GND
Related manuals
Manual 90 pages 24.16 Kb