8. Printing Procedures (Special prints)
External REMOTE 2 terminal on the rear panel
The images can be stored in memory and printed by sending the remote signal through the external remote terminal on the rear panel.
, Make out the necessary circuit to use this function by referring to the following.
Pin No.
1External remote terminal Signal allocation Connector MINI DIN8PIN
Pin No. | Function | Description |
1 | Ground | Earth |
2 | MEMORY | Memory: When the signal becomes “LOW” from “HIGH”, the image is stored in |
|
| memory. (When the signal has been “LOW” for 60msec. or more, the image is |
|
| stored in memory. ) |
3Unused
4 | BUSY | “HIGH” : The VCP cannot accept the remote signal. | |
|
| “LOW” : The VCP can accept the remote signal. | |
|
| The signal becomes “HIGH” in the following cases; | |
|
| (1) | During initialization after the VCP has been switched on |
|
| (2) | For about 1 sec. after the INPUT SELECT switch has been set |
|
| (3) | During displaying the menu screen |
|
| (4) | When the image cannot be stored in memory |
|
|
| |
5 | PRINT :When the signal becomes “LOW” from “HIGH”, the image stored in | ||
|
| the memory is printed. (When the signal has been “LOW” for 60 msec. or | |
|
| more, the image is printed.) | |
|
|
| |
6 | REMOTE | The same functions as the remote control can be controlled.∗ | |
7 | Unused |
|
|
8 | DC3V | Power supply for the remote control DC 1mA MAX | |
|
| ∗Refer to page 82 for this function. |
,When the signal from BUSY terminal is received with TTL level, keep the following. 1 OL =2mA or less, 1 OH =1mA or less
1 OL shows the current flowing into the unit at Low output, 1 OH shows the current flowing out of the unit at High output.