JVC VR601 instruction manual PRE- Alarm

Page 22

REC QUALITY:

This option determines the image quality to be recorded when an alarm input occurs. There are 4 levels of image quality to choose from: BEST, HIGH, STANDARD, and BASIC. The table below shows the level of image quality with the corresponding compression ratio and image size.

Image Quality

 

Compression Ratio

 

 

Best

High

Standard

Basic

Image Size

48KB

32KB

21KB

16KB

 

 

 

 

 

AUDIO:

This option determines the way to record sound if necessary.

ON: Enables AUDIO recording.

OFF: Disables AUDIO recording.

NOTE: Audio function can only be activated in the following refresh rate in NTSC(PAL): 12(10), 5.5(5.5), 2.4(2.9), 1.22(1.52), 0.71(0.88) fields/sec

ALM TYPE:

This option allows users to set a type of alarm input corresponding to the sensor signal in use.

NO: Normally Open. This is to be used with the type of alarm sensor whose contact remains open in normal conditions and closes in case of activation.

NC: Normally Closed. This is to be used with the type of alarm sensor whose contact remains closed in normal conditions and opens in case of activation.

ALM DURATION:

This option allows users to set alarms for a certain duration. You can select one of the six following options: 0 SEC, 30SEC, 1 MIN, 5 MIN, 10 MIN, and NON-STOP.

D uration Set ting

 

 

Alarm recording

 

 

 

 

Duration

 

 

 

 

 

 

 

 

 

 

Alarm

Alarm

 

activated

deactivated

 

Non-Stop

Alarm recording

 

 

 

 

 

 

 

Duration

 

 

 

 

 

 

 

 

 

 

Alar

m

Alar m

Reset

activated

deactivated

 

NOTE: Recording may be interrupted at the time of Alarm-in or Alarm-out. LIVE images may be interrupted at the time of Alarm-out.

PRE- ALARM:

This option determines that images prior to an alarm occurs will be recorded in the hard-disk drive. When an alarm is triggered the device will record the image prior to the alarm for 5 seconds in NTSC (**20 fields/sec) or 6 seconds in PAL (**17 fields/sec).

ON: Enables this function.

OFF: Disables this function.

NOTE: If the device is already under recording mode before alarm occur, the pre-alarm recording would not take effect.

**: For NTSC and Mux Off Mode, recording rate 20F/S would be actually 15 F/S For PAL and Mux Off Mode, recording rate 17F/S would be actually 12.5 F/S.

( This adjustment is to avoid image shaking during playback at the same speed )

42

43

Image 22
Contents Digital Video Recorder Safety Precautions for USA and Canada AvertissementSafety Precautions for Europe and Australia Power SystemTable Of Contents Product Features Product FeaturesProduct Introduction Description of the FRONT/REAR View Front ViewʽTHIS Figure is Looked from the Rear Rear View Alarm In/OutNo Connection Connecting with a Multiplexer InstallationConnecting with a Single Camera Basic ConnectionAttaching AN External Device to DVR Connecting with a QuadClock SET IDE Hard-Disk Drive InstallationSystem Information Quality Best Ntsc Rate 6 HRUpdating System Software Configuring Recording SettingsBasic Operations Ntsc MUX onPAL MUX on Audio OFFPAL MUX OFF Recording Operations Timer RecordingManual Recording Alarm Recording Externally triggered RecordingFast Forward/Reverse Playback OperationsREC Stop Play Play Back Recorded Video from a HDD of the mobile rack Search OperationsSlow Forward/Reverse Full List SearchThumbnail Search Alarm list SearchTime Search Mobile Rack HD Backup Backup OperationsSD Card Search Disk Setting Reformat HD2 Usage Secure Digital Card SD Card Backup Alarm Select Main Backup Alarm to HD2 Save to J0000.JPGKey Lock Operation Menu SetupTransfer the system setting info of DVR to another KEY FunctionsPRE- Alarm OFF Main Alarm REC Enable REC Quality REC SettingAlarm Setting REC Quality Best Disk FullPRE- Alarm NET Enable Clock / TimerNET Enable OFF NET Dhcp NET IP SET FTP Setting Main CommunicationREC Mode Alarm REC Comm Setting FTP Setting Comm IDEnable REC ModeMain Menu Record Disk Setting Disk Setting SystemHD 1 MAC Menu Backgnd SD SetupBios DateCommunication Protocol SetupRS-232 & RS-485 Protocol DEC HEXMobile Rack Installation Page System Default SET RS232 / RS485D Message Meanings S.D MessageNetwork Viewer and Image Viewer Network ViewerURL of a Proxy CancelView the VR-601 video from a remote PC PortView single device Viewing images View all the connected devicesFunction Buttons Description Set the Alarm record settings Change the Record & Timer Properties Via the NetworkSet the regular record settings Set the record timerImage Viewer Archive Images to the ComputerNetwork Configuration Index TableConfigure Your DVR Network Settings RJ-45 PIN configuration for LAN HubEnable Dhcp Function Enable DVR Network Function12.3 TCP/IP Communication Software Connection Testing 12.4 TCP/IP installation12.5 TCP/IP Configuration setting Click Start Æ Settings Æ Control Panel Æ NetworkDesign and specifications subject to change without notice SpecificationsModel Number VR-601 U VR-601 E Colors Compatible MultiplexersManufacturer Model Channel Decode onPrecautions