JVC VR601 Clock / Timer, Communication, NET Enable OFF NET Dhcp NET IP SET FTP Setting Main

Page 23

5.3 CLOCK / TIMER

The DVR provides a weekly table, consisting of two periods of time each day for scheduled recording. This option allows you to set the time each day that the DVR will start and stop recording.

5.4 COMMUNICATION

This option allows you to configure the status of the RS-232 communication port when connected to an external device, and the Ethernet communications settings. (Please refer to the RS-232 Protocol and Network Function for more details)

MAIN MENU

RECORD

ALARM

CLOCK / TIMER

COMMUNICATION

DISK

SYSTEM

GOTO TIMER PAGE

CLOCK:

This entry allows users to set the system time.

 

CLOCK / TIMER

 

 

CLOCK

: SET

 

 

 

: OFF

 

REC ENABLE

 

TIMER

 

: SET

 

MAIN PAGE

 

 

TIMER REC ENABLE

 

MAIN MENU

RECORD

ALARM CLOCK / TIMER COMMUNICATION DISK

SYSTEM

GOTO COMM PAGE

COMM SETTING

COMM ID

 

: 01

RS232

 

: ON

RS485

: ON

NET ENABLE

: OFF

NET DHCP

: OFF

NET IP

: SET

FTP SETTING

 

MAIN PAGE

SET RS232 / RS485 ID

NOTE: Clock data is retained for about 3 months after the 15-hour power supply is used up (Operate On mode).

REC ENABLE:

This option enables/disables the programmed scheduled recording.

ON: Enables the scheduled recording.

OFF: Disables the scheduled recording.

TIMER:

This entry allows users to program the time each day that the DVR will start and stop recording. There are two time periods each day available for scheduling. The time is displayed in a 24-hour clock format. If there is a time overlapping showing between two continual time period settings, the device will automatically combine the two time-period settings into one combined time-period setting.

REC SCHEDULE

 

REC SCHEDULE

START END

START END

 

START END

START END

S :06:00-16:00

12:00-18:00

 

S :06:00-18:00

00:00-00:00

 

 

 

 

 

COMM ID:

Communication ID for RS-232 and RS-485 communication. After the VR-601 receives a RS-232 or RS-485 command, it checks if the <Dest ID> within the code is the same as the COMM ID, in which case the particular command can be accept.

RS-232:

The RS-232 communication port can be either in an importing or exporting mode according to your applications.

ON: Enables the RS-232 communication port. When you wish the unit to be controlled by an external device, please select this entry for use.

OFF: Disables the RS-232 communication port.

RS-485:

The RS-485 communication port can be either in an importing or exporting mode according to your applications.

ON: Enables the RS-485 communication port. When you wish the unit to be controlled by an external device, please select this entry for use.

OFF: Disables the RS-485 communication port.

NET ENABLE:

This option selects either enable or disable for the Ethernet communication port. OFF:Disables it.

ON: Enables it.

44

45

Image 23
Contents Digital Video Recorder Avertissement Safety Precautions for USA and CanadaPower System Safety Precautions for Europe and AustraliaTable Of Contents Product Introduction Product FeaturesProduct Features Front View Description of the FRONT/REAR ViewNo Connection Rear View Alarm In/OutʽTHIS Figure is Looked from the Rear Basic Connection InstallationConnecting with a Single Camera Connecting with a MultiplexerClock SET Connecting with a QuadAttaching AN External Device to DVR Quality Best Ntsc Rate 6 HR Hard-Disk Drive InstallationSystem Information IDENtsc MUX on Configuring Recording SettingsBasic Operations Updating System SoftwarePAL MUX OFF Audio OFFPAL MUX on Manual Recording Timer RecordingRecording Operations Externally triggered Recording Alarm RecordingREC Stop Play Playback OperationsFast Forward/Reverse Full List Search Search OperationsSlow Forward/Reverse Play Back Recorded Video from a HDD of the mobile rackTime Search Alarm list SearchThumbnail Search SD Card Search Backup OperationsMobile Rack HD Backup Save to J0000.JPG Secure Digital Card SD Card BackupAlarm Select Main Backup Alarm to HD2 Disk Setting Reformat HD2 UsageKEY Functions Menu SetupTransfer the system setting info of DVR to another Key Lock OperationREC Quality Best Disk Full REC SettingAlarm Setting PRE- Alarm OFF Main Alarm REC Enable REC QualityPRE- Alarm Communication Clock / TimerNET Enable OFF NET Dhcp NET IP SET FTP Setting Main NET EnableREC Mode Comm Setting FTP Setting Comm IDEnable REC Mode Alarm RECHD 1 Disk Setting SystemMain Menu Record Disk Setting Date Menu Backgnd SD SetupBios MACDEC HEX SetupRS-232 & RS-485 Protocol Communication ProtocolMobile Rack Installation Page SET RS232 / RS485 System DefaultNetwork Viewer S.D MessageNetwork Viewer and Image Viewer D Message MeaningsPort CancelView the VR-601 video from a remote PC URL of a ProxyFunction Buttons Description Viewing images View all the connected devicesView single device Set the record timer Change the Record & Timer Properties Via the NetworkSet the regular record settings Set the Alarm record settingsArchive Images to the Computer Image ViewerIndex Table Network ConfigurationEnable DVR Network Function RJ-45 PIN configuration for LAN HubEnable Dhcp Function Configure Your DVR Network Settings12.3 TCP/IP Communication Software Click Start Æ Settings Æ Control Panel Æ Network 12.4 TCP/IP installation12.5 TCP/IP Configuration setting Connection TestingModel Number VR-601 U VR-601 E SpecificationsDesign and specifications subject to change without notice Decode on Compatible MultiplexersManufacturer Model Channel ColorsPrecautions