5.Run the installation program by typing in the following command and pressing the <Enter> key.
./vnrecorder_install
6.A series of prompts will start to request configuration information. Use the config.xml and the admin.xml files (see the Gathering Firmware Installation Information section on page 64) while using the Firmware Installation Table below to fill in the requested configuration information.
NOTES: | |
• | The Controller options and Controller checksum prompts require an options |
| key and a checksum which is provided by Extron. |
• If keys have been previously provided by Extron, they can be found within the | |
| admin.xml file. See "Controller options:" and "Controller checksum:" in the |
| Firmware Installation Table below. |
Firmware Installation Table
Prompt | Value to Enter | Xml File | Value |
|
| Reference | Reference |
|
|
|
|
User name to run | zz matrix_rec | none | none |
application: |
|
|
|
|
|
|
|
Serial number: | zz Serial number of the VNM Recorder | config.xml | serial |
|
|
|
|
Licensed Recorder | zz Check the R value (for example, | config.xml | structure |
channels: | R5, P5, mR, mP, mV determines that 5 is the |
|
|
| necessary value). |
|
|
| zz 5 is the default value. |
|
|
|
|
|
|
Recorder GUI enabled | zz Check the mV value (for example, | config.xml | structure |
(yes/no): | R5, P5, mR, mP, mV). |
|
|
| zz If mV is present, answer Yes. Otherwise, answer No. |
|
|
|
|
|
|
License checksum: | zz Checksum of the VNM Recorder | config.xml | checksum |
| zz Copy and paste the value |
|
|
Controller IP | zz The IP address of the device acting as the system | config.xml | st_controlIP |
address: | controller |
|
|
|
|
| |
|
|
|
|
Controller port | zz The controller port number | config.xml | st_controlPort |
number: | zz The default value is 5432 |
|
|
|
|
| |
|
|
|
|
Local IP address: | zz The IP address of the VNM Recorder | config.xml | st_localIP0 |
Controller options: | zz This is the options key provided by Extron for use in | admin.xml | options |
| VNM Recorders acting as the system controller. |
|
|
| zz If no data is provided or available, leave blank or |
|
|
| contact the Extron S3 Sales and Technical Support |
|
|
| Hotline and ask for a structure key. |
|
|
|
|
|
|
Controller checksum: | zz This is the checksum provided by Extron for use in | admin.xml | checksum |
| VNM Recorders acting as the system controller. |
|
|
| zz If no data is provided or available, leave blank or |
|
|
| contact the Extron S3 Sales and Technical Support |
|
|
| Hotline and ask for a license key. |
|
|
|
|
|
|
Control port: | zz The controller port number | config.xml | st_controlPort |
| zz The default value is 5432 |
|
|
VNM Recorder • Firmware Updates | 66 |