Vidikron Vision 75, Vision 65 operation manual Adjusting the Lens Height Y

Page 57

Installation

Ceiling Mount Bracket

Adjusting the Lens Height (Y):

1.Project a white field on the screen.

2.Ensure that the Pitch/Y-Adjustment Screws are loose enough to allow vertical movement of the lens assembly.

3.Slowly move the anamorphic lens into place so that there are no shadows on the top or bottom of the screen:

Too Low

Correct position

Too High

4.When the height is properly set, tighten the Pitch/Y-Adjustment Screws to secure the lens in place.

Adjusting the Pitch (Angle): Next, angle the lens to even out any top-to-bottom pincushion distortion. To do this, loosen the Pitch/Y-Adjustment Screws on either side of the lens to allow it to pivot freely. Then, adjust the anamorphic lens angle so that the projected image is rectangular:

Correct Lens Angle

Incorrect Lens Angle

Vidikron Vision Model 65/Model 75 Installation/Operation Manual

41

Image 57
Contents 65/75 Page TWO Year Limited Warranty RIGHTS, Limits and Exclusions Product Information Retain for Your Records Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part Table of Hazardous Substances Model Name Vision Model 75 Series 1Table of Contents Operation Maintenance and TroubleshootingSerial Communications Table of Contents Xiv 1List of Figures CIE 1931 Chromaticity Diagram 1Introduction About This ManualThis Manual If you need Turn to Using This ManualDescription, Features and Benefits Optional Accessories Vision 65/75 Front/Side/Top View Vision 65/75 at a GlanceTemp LED POWER/STANDBY LED Indicates power status as followsVision 65/75 Rear/Bottom/Side View Cable Access Door Open to access connectorsVision 65/75 Rear Panel Hdmi 2 Digital Comp 1 RCA connectorsVision 65/75 Remote Control Volt 250 mA Trigger Output 3.5-mm, mini phono jackComp 2 / RGB Source Selection Buttons On / OFFVID S-Video Cursor KeysMemory Preset Buttons Picture Adjustment Buttons BRT BrightnessContrast COL ColorLens Picture-In-Picture PIP Controls3Installation Remote ControlOperation Installation Overview Quick SetupStep Procedure For Details, Refer to If installing a CineWide-equipped projector InstallProjector Installation Options Installation ConsiderationsInstallation Type Advantages ConsiderationsThrow Ratios for the Vision 65/75 Series Throw Range Throw RatioProjector Model Ceiling Installation Floor InstallationVertical and Horizontal Position Up/down vertical lens shift percentages Fixed CineWide Base Plate Cylindrical Lens Installing the Optional CineWide Lens MountMotor AutoScope motor assemblyVision 65/75 with Ceiling Mount Adapters/Projector Stands AutoScope Lens Motor Installation Install Lens MotorDo not OVER-TIGHTEN the Screws Base Plate Prismatic LensVision 65/CineWide or Vision 75/CineWide Floor Mounting Upright Mounting the Vision 65/75Adjusting the Projector Using the On-Screen Menus onHeight or Projection Angle Connecting Source Connections to the Vision 65/7565/75 11. RGB Connections 13. Composite, S-Video and Component Video Connections 14. RS-232 Control System Connection ConnectionAutoScope Lens Motor Rear 16. Connecting the 12-Volt Trigger Output to Other EquipmentPower source Turning on the PowerPrimary Lens Adjustments Changing the OSD Language Adjusting the Picture OrientationZoom Zo om Out FocusInstalling and Adjusting the CineWide Anamorphic Lens These instructions 18. Attaching the Anamorphic Lens to the Lens Adapter Ring Attach Lens Mounting Assembly to Lens Motor Carriage PlateAdjusting the Horizontal X Lens Position Installation Anamorphic Lens Top View Adjusting the GeometryWhitney Prismatic AdjustmentAdjusting the Lens Height Y Anamorphic Lens Top View 4Operation Selecting an Aspect Ratio Adjusting the PictureSelecting Video Memory Selecting An Input SourceUsing the On-Screen Menus Using Picture-In-Picture PIPPicture Adjust SetupInstallation Source SelectPicture Adjust Perform the adjustments in the order listed hereSource Select Typical Pluge Pattern for Adjusting Brightness You must enter a passcode to access the ISF menuTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness Aspect Ratio Settings Aspect RatioDescription Cinema Fit a 2.351 screen InstallationVertical Keystone Correction Horizontal Keystone CorrectionPincushion Correction Operation Information SetupRefer to the instructions for your computer This menu should be used by ISF-certified technicians only Is powered off, then on againSettings reduce the image brightness CIE 1931 Chromaticity Diagram Operation 5Maintenance and Troubleshooting Lamp ReplacementLamp assembly for replacement Troubleshooting Tips Troubleshooting ChartSymptom Possible Causes Solution Troubleshooting Chart Maintenance and Troubleshooting RS-232 Connection and Port Configuration Serial Command SyntaxSerial Commands 6Serial CommunicationsSerial Communications Serial Commands Serial Communications Vision 65/75 Specifications 7SpecificationsHome Theater Calibration Specifications Vision Specifications Vision Model 75 SeriesIndustry-Standard Specifications Vision Model 65 Series Industry-Standard Specifications Vision Model 75 SeriesDimensions Power RequirementsWeight without lens Limited WarrantyVision 65/75 Dimensions with Optional Fixed Anamorphic Lens Vision 65/75 DimensionsSupported Signal Timings Supported Timings Format ResolutionMHz Format Resolution Refresh Rate Hz Horizontal Pixel Frequency Supported Signal TimingsSdtv Signals Video / S-Video Specifications Page 020-0715-02 Rev. a March