4. Operation

1.Turn on your source components.

2.Press the main power switch on the CinemaWall (see Figure 2-1or Figure 2-2). The standby/on indicator lights green.

3.After a brief warm-up period (approximately five seconds), the CinemaWall will display an image.

4.Press the POWER button on the remote control to put the CinemaWall into standby

mode. The power indicator lights solid red.

5. Press the POWER button again to return to normal operation.

The CinemaWall OSD language is initially set to English, but can also display the menus in Russian, German, French, Italian or Spanish. To change the OSD language:

1.Press SET UP on the remote control unit.

2.Press repeatedly until OSD LANGUAGE is highlighted.

3.Press or to select the desired language. The change takes effect immediately.

4.1

Turning on the Power

4.2

Changing the OSD Language

You can program the CinemaWall to perform various actions, such as turning on or off, at specific times of the day and days of the week. In order to take advantage of this capability, the CinemaWall internal clock must be set correctly. To do this:

1.Press SET UP on the remote control unit.

2.Press or repeatedly until PRESENT TIME SETUP is highlighted.

3.Press the ACTION () button.

4.

Press

or

repeatedly to highlight DAY

 

 

 

 

 

 

 

 

PRESENT TIME SETUP

 

 

 

 

 

in the menu.

 

 

 

PRESENT TIME OF DAY MON 99:99

5.

Press

or

to select the current day of

 

 

 

 

 

 

 

 

 

 

SET

 

 

 

 

 

the week.

 

 

DAY

 

 

TUE

 

 

 

 

PRESENT TIME OF DAY

 

 

10:00

 

 

 

 

 

 

 

 

 

6.

Repeat Steps 4 and 5 to set the current

 

 

 

 

RETURN

 

time of day.

 

 

 

SELECT

 

SET

 

 

 

 

 

 

 

 

 

 

 

 

7.Press or repeatedly to highlight SET

in the menu, then press the ACTION () button.

4.3

Setting the Day and Time

CinemaWall XP-50/XP-65 Installation/Operation Manual

21

Image 35
Contents XP-50 XP-65 Page RuncoCare Standard Features RuncoCare Standard Two Year Limited WarrantyRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part Page Table of Contents Operation Maintenance and TroubleshootingSpecifications Appendix A. Default SettingsList of Figures List of Figures Xiv About This Manual IntroductionDegrade performance or cause a malfunction Using This ManualCertain features Significance. They also provide supplemental informationKey Features and Benefits Description, Features and BenefitsOptional Accessories XP-50 CinemaWall at a Glance Controls and IndicatorsControls and Functions Display Stand XP-506 XP-65 ConnectorsPower Input Surround button CinemaWall Remote ControlControls and Functions Other surfaces InstallationRemote Control Step Procedure For Details, refer to Quick SetupInstallation specialist Installation Considerations Ventilation Ambient LightOther Considerations Components to Connecting SourceConnections to CinemaWallRCA-BNC adapter plug Analog RGB Connections Connection Connecting External Speakers OptionalConnector Pin Assignments RS-232 ControllerAC Power Connection Operation Turning on the Power Changing the OSD LanguageSetting the Day and Time Setting the Computer Display Properties Aspect ratio selection is saved independently for each input Selecting an Input Source Changing the Aspect Ratio149 169Edges of the screen 43 431 linearly scalesSource image horizon Played at the left and rightActivating PIP Swapping the Main PIP Images Using Picture-In-Picture PIPChanging the PIP Window Position Using the On-Screen MenusSelecting a PIP Target Screen or Input SourcePOS./SIZE Options Picture This control is not available when Picture Menu is set to Typical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness POS./SIZE CinemaWall memorizes position and size settings separatelyFrequency is 108 MHz or greater Options menu refer to page 50 is set to OnSound Or 1080p and the Aspect Ratio is set to 169 refer toSET UP Signal Screensaver Is active On the remote control unit, or cycle power to the CinemaWall Order to activate multi-display mode, you must first set Refer to Changing the OSD Language onOn hides joints between displays C D Insert cannot be used when Transparency is set to on Transparency cannot be used when Insert is set to onPresent Time Setup Refer to Setting the Day and Time on Command Timer refer toDVD3 Operation Refer to Return ChangeCurrently active Level see belowPicture menu is set to Warm When using multiple displays such as in a video wall RuncoSome cases, power is transmitted to the slot when MULTI-DISPLAY is activeOn page 21, the Clock Display setting has no effect Using Digital ZoomDuring the delay period, the power indicator flashes green Operation Cleaning the Screen Maintenance and TroubleshootingCleaning Cleaning the Display Panel Body and Remote ControlSymptom Possible Causes Solution Troubleshooting TipsExamples Command 3 bytes Parameter 3 bytesCommand 3 bytes Parameter 6 bytes Serial CommunicationsHex Description Serial CommandsDwaovlon OSPSCR0 CinemaWall Specifications SpecificationsCinemaWall Model XP-50 Dimensions with Optional Table Stand CinemaWall DimensionsCinemaWall Model XP-65 Dimensions with Optional Table Stand Supported Timings Supported Signal Timings by Input Specifications Table A-1. Runco Factory Default Settings for CinemaWall Appendix A. Default SettingsDefault Settings Page 020-0970-00 Rev. B March