Runco XP-50, XP-65 operation manual Appendix A. Default Settings

Page 79

Appendix A. Default Settings

Table A-1lists the CinemaWall factory-default image settings. All of these settings are in the PICTURE menu except for 1:1 PIXEL MODE, which is in the POS./SIZE menu.

Table A-1. Runco Factory Default Settings for CinemaWall

 

 

Model XP-50

 

 

Model XP-65

 

 

 

 

 

 

 

 

 

 

Menu Setting

 

 

 

PICTURE MENU Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

ISF Night

STANDARD

ISF DAY

MONITOR

ISF Night

STANDARD

ISF DAY

MONITOR

 

 

 

 

 

 

 

 

 

PICTURE

30

30

30

30

30

30

 

 

 

 

 

 

 

 

 

BRIGHTNESS

-5

-2

-2

0

-6

-4

-4

0

 

 

 

 

 

 

 

 

 

COLOR

-2

-2

-2

0

-2

-2

-2

0

 

 

 

 

 

 

 

 

 

TINT

0

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

SHARPNESS

3

3

3

0

5

5

5

0

 

 

 

 

 

 

 

 

 

COLOR TEMP

NORMAL

NORMAL

NORMAL

WARM

NORMAL

NORMAL

NORMAL

WARM

 

 

 

 

 

 

 

 

 

COLOR

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

MANAGEMENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADVANCED SETTINGS

ON

ON

ON

OFF

ON

ON

ON

OFF

 

 

 

 

 

 

 

 

 

BLACK EXTENSION

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

INPUT LEVEL

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

GAMMA

2.2

S-Curve

S-Curve

2.2

S-Curve

S-Curve

 

 

 

 

 

 

 

 

 

AGC

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

R GAIN

3

3

3

-2

-2

-2

 

 

 

 

 

 

 

 

 

G GAIN

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

B GAIN

-18

-18

-18

-14

-14

-14

 

 

 

 

 

 

 

 

 

R OFFSET

-11

-11

-11

-1

-1

-1

 

 

 

 

 

 

 

 

 

G OFFSET

-7

-7

-7

-2

-2

-2

 

 

 

 

 

 

 

 

 

B OFFSET

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

1:1 Pixel Mode

On

On

On

Off

On

On

On

Off

(POS./SIZE menu)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CinemaWall XP-50/XP-65 Installation/Operation Manual

A-1

Image 79
Contents XP-50 XP-65 Page RuncoCare Standard Features RuncoCare Standard Two Year Limited WarrantyRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part Page Table of Contents Operation Maintenance and TroubleshootingSpecifications Appendix A. Default SettingsList of Figures List of Figures Xiv About This Manual IntroductionDegrade performance or cause a malfunction Using This ManualCertain features Significance. They also provide supplemental informationKey Features and Benefits Description, Features and BenefitsOptional Accessories XP-50 Controls and Functions Controls and IndicatorsCinemaWall at a Glance Display Stand XP-506 XP-65 ConnectorsPower Input Surround button CinemaWall Remote ControlControls and Functions Remote Control InstallationOther surfaces Installation specialist Quick SetupStep Procedure For Details, refer to Installation Considerations Ventilation Ambient LightOther Considerations Components to Connecting SourceConnections to CinemaWallRCA-BNC adapter plug Analog RGB Connections Connection Connecting External Speakers OptionalConnector Pin Assignments RS-232 ControllerAC Power Connection Setting the Day and Time Turning on the Power Changing the OSD LanguageOperation Setting the Computer Display Properties Aspect ratio selection is saved independently for each input Selecting an Input Source Changing the Aspect Ratio149 169Edges of the screen 43 431 linearly scalesSource image horizon Played at the left and rightActivating PIP Swapping the Main PIP Images Using Picture-In-Picture PIPChanging the PIP Window Position Using the On-Screen MenusSelecting a PIP Target Screen or Input SourcePOS./SIZE Options Picture This control is not available when Picture Menu is set to Typical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness POS./SIZE CinemaWall memorizes position and size settings separatelyFrequency is 108 MHz or greater Options menu refer to page 50 is set to OnSound Or 1080p and the Aspect Ratio is set to 169 refer toSET UP Signal Screensaver Is active On the remote control unit, or cycle power to the CinemaWall Order to activate multi-display mode, you must first set Refer to Changing the OSD Language onOn hides joints between displays C D Insert cannot be used when Transparency is set to on Transparency cannot be used when Insert is set to onPresent Time Setup Refer to Setting the Day and Time on Command Timer refer toDVD3 Operation Refer to Return ChangeCurrently active Level see belowPicture menu is set to Warm When using multiple displays such as in a video wall RuncoSome cases, power is transmitted to the slot when MULTI-DISPLAY is activeDuring the delay period, the power indicator flashes green Using Digital ZoomOn page 21, the Clock Display setting has no effect Operation Cleaning the Screen Maintenance and TroubleshootingCleaning Cleaning the Display Panel Body and Remote ControlSymptom Possible Causes Solution Troubleshooting TipsExamples Command 3 bytes Parameter 3 bytesCommand 3 bytes Parameter 6 bytes Serial CommunicationsHex Description Serial CommandsDwaovlon OSPSCR0 CinemaWall Specifications SpecificationsCinemaWall Model XP-50 Dimensions with Optional Table Stand CinemaWall DimensionsCinemaWall Model XP-65 Dimensions with Optional Table Stand Supported Timings Supported Signal Timings by Input Specifications Table A-1. Runco Factory Default Settings for CinemaWall Appendix A. Default SettingsDefault Settings Page 020-0970-00 Rev. B March