Runco XP-65, XP-50 operation manual Pos./Size

Page 42

Operation

• The OSD menu closes after 60 seconds of inactivity.

The CinemaWall OSD menus are arranged hierarchically, as shown in Figure 4-1.Depending on the selected input source and signal characteristics, some menu options may not be available.

 

H-POS

 

 

 

H-SIZE

-124, -123 ... 0 ... 123, 124

 

 

 

 

 

 

V-POS

 

 

 

 

 

 

 

V-SIZE

-62, -61 ... 0 ... 61, 62

 

POS./SIZE

 

 

 

DOT CLOCK

-32, -31 ... 0 ... 31, 32

 

 

(INPUT3/PC INPUT only)

 

 

 

CLOCK PHASE

-16, -15 ... 0 ... 15, 16

 

 

(INPUT3/PC INPUT only)

 

 

 

 

 

 

 

 

 

1:1 PIXEL MODE

ON / OFF

 

 

(1080i/1080p signals only)

 

 

 

 

 

 

 

 

 

PICTURE MENU

STANDARD, ISF DAY, ISF NIGHT or MONITOR

 

 

 

 

 

 

PICTURE

 

 

 

 

 

 

 

BRIGHTNESS

-30, -29 ... 0 ...29, 30

 

 

 

 

 

COLOR

 

 

 

 

 

 

 

 

 

TINT

 

 

 

 

 

 

 

SHARPNESS

-15, -14 ... 0 ... 14, 15

 

 

 

 

 

 

COLOR TEMP

NORMAL, COOL or WARM

 

 

 

 

 

PICTURE

COLOR MANAGEMENT

ON/OFF

 

 

 

 

ADVANCED SETTINGS

--

 

 

 

 

(OFF)

 

 

 

 

 

 

 

 

 

 

BLACK EXTENSION

0, 1, 2 ... 8

 

 

 

 

 

 

INPUT LEVEL

-32, -31, -30 ... 0 ... 30, 31, 32

 

 

 

 

 

ADVANCED SETTINGS

GAMMA

2.0, 2.2, 2.5 or S-CURVE

 

(ON)

AGC

OFF/ON

 

 

 

 

 

 

R/G/B GAIN

-30, -29 ... 0 ...29, 30

 

 

R/G/B OFFSET

 

 

 

 

 

 

 

 

AUDIO MENU

STANDARD, DYNAMIC or CLEAR

 

 

 

 

 

 

BASS

 

 

 

 

-15, -14, -13 ... 0 ... 13, 14, 15

 

SOUND

MID

 

 

 

 

TREBLE

 

 

 

BALANCE

-30, -29, 28 ... 0 ... 28, 29, 30

 

 

 

 

 

 

SURROUND

ON/OFF

 

 

 

 

 

 

AUDIO OUT (PIP)

MAIN or SUB

 

 

 

 

 

 

 

SYNC

AUTO, ON G or VBS

 

 

(PC INPUT only)

 

 

 

 

 

 

 

 

 

3:2 PULLDOWN

OFF/ON

 

 

 

 

 

 

XGA MODE

1024x768, 1280x768 or 1366x768

 

SIGNAL

(INPUT3/PC INPUT only)

 

 

 

 

 

 

 

NOISE REDUCTION

OFF, MIN, MID or MAX

 

 

 

 

 

 

 

VIDEO NR (OFF, MIN, MID or MAX)

 

 

NOISE REDUCTION - ADVANCED

 

 

 

BLOCK NR (OFF, MIN, MID or MAX)

 

 

 

 

 

 

 

MOSQUITO NR (OFF, MIN, MID or MAX)

 

 

 

 

 

 

START

 

 

 

 

 

 

 

FUNCTION

SCROLLING BAR ONLY, OVERLAY SCROLLING

 

 

BAR, WHITE SCREEN or NEGATIVE IMAGE

 

 

 

 

 

 

 

 

 

MODE

ON, OFF, INTERVAL or TIME OF DAY

SET UP

 

 

 

SCREENSAVER

START TIME/SHOW DURATION

0:00 ... 23:59 / 0:00, 0:15, 0:30 ... 23:45

(1/2)

 

FINISH TIME/SAVER DURATION

0:00 ... 23:59 / 0:00, 0:15, 0:30 ... 23:45

 

 

 

 

SIDE BAR ADJUST

OFF, DARK, MID or BRIGHT

 

 

 

 

 

 

 

 

WOBBLING

OFF, ON1 or ON2

 

 

 

 

 

 

PEAK LIMIT

OFF/ON

 

 

 

 

 

COMPONENT/RGB IN SELECT

COMPONENT or RGB

 

 

 

 

 

 

 

INPUT[n], VIDEO[n], COMPONENT[n], RGB[n],

 

 

INPUT LABEL

DIGITAL [1A/1B/2A/2B], PC[n], DVD[n],

 

 

 

CATV[n], VCR[n], STB[n]

 

 

 

 

 

 

POWER SAVE

 

 

 

 

 

 

 

STANDBY SAVE

OFF/ON

 

 

 

 

 

POWER MANAGEMENT

 

 

 

 

 

 

 

 

 

AUTO POWER OFF

 

 

 

 

 

 

 

 

ENGLISH (US), Русский (RUSSIAN), Deutsch

 

 

OSD LANGUAGE

(GERMAN), Français, (FRENCH), italiano

 

 

 

(ITALIAN) or Español (SPANISH)

 

 

 

 

 

Figure 4-1. OSD Menu Structure for CinemaWall

28

CinemaWall XP-50/XP-65 Installation/Operation Manual

Image 42
Contents XP-50 XP-65 Page RuncoCare Standard Two Year Limited Warranty RuncoCare Standard FeaturesRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Compliance Information Declaration of ConformityFCC Part Page Table of Contents Appendix A. Default Settings Maintenance and TroubleshootingSpecifications OperationList of Figures List of Figures Xiv Introduction About This ManualSignificance. They also provide supplemental information Using This ManualCertain features Degrade performance or cause a malfunctionDescription, Features and Benefits Key Features and BenefitsOptional Accessories XP-50 Controls and Indicators Controls and FunctionsCinemaWall at a Glance Display Stand Connectors XP-506 XP-65Power Input CinemaWall Remote Control Surround buttonControls and Functions Installation Remote ControlOther surfaces Quick Setup Installation specialistStep Procedure For Details, refer to Installation Considerations Ambient Light VentilationOther Considerations CinemaWall Connecting SourceConnections to Components toRCA-BNC adapter plug Analog RGB Connections RS-232 Controller Connecting External Speakers OptionalConnector Pin Assignments ConnectionAC Power Connection Turning on the Power Changing the OSD Language Setting the Day and TimeOperation Setting the Computer Display Properties Selecting an Input Source Changing the Aspect Ratio Aspect ratio selection is saved independently for each input169 149Played at the left and right 43 431 linearly scalesSource image horizon Edges of the screenUsing Picture-In-Picture PIP Activating PIP Swapping the Main PIP ImagesScreen or Input Source Using the On-Screen MenusSelecting a PIP Target Changing the PIP Window PositionPOS./SIZE Options Picture This control is not available when Picture Menu is set to Typical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness CinemaWall memorizes position and size settings separately POS./SIZEOptions menu refer to page 50 is set to On Frequency is 108 MHz or greaterOr 1080p and the Aspect Ratio is set to 169 refer to SoundSET UP Signal Screensaver Is active On the remote control unit, or cycle power to the CinemaWall Refer to Changing the OSD Language on Order to activate multi-display mode, you must first setOn hides joints between displays C D Transparency cannot be used when Insert is set to on Insert cannot be used when Transparency is set to onCommand Timer refer to Present Time Setup Refer to Setting the Day and Time onDVD3 Operation Return Change Refer toLevel see below Currently activeMULTI-DISPLAY is active When using multiple displays such as in a video wall RuncoSome cases, power is transmitted to the slot when Picture menu is set to WarmUsing Digital Zoom During the delay period, the power indicator flashes greenOn page 21, the Clock Display setting has no effect Operation Cleaning the Display Panel Body and Remote Control Maintenance and TroubleshootingCleaning Cleaning the ScreenTroubleshooting Tips Symptom Possible Causes SolutionSerial Communications Command 3 bytes Parameter 3 bytesCommand 3 bytes Parameter 6 bytes ExamplesSerial Commands Hex DescriptionDwaovlon OSPSCR0 Specifications CinemaWall SpecificationsCinemaWall Dimensions CinemaWall Model XP-50 Dimensions with Optional Table StandCinemaWall Model XP-65 Dimensions with Optional Table Stand Supported Timings Supported Signal Timings by Input Specifications Appendix A. Default Settings Table A-1. Runco Factory Default Settings for CinemaWallDefault Settings Page 020-0970-00 Rev. B March