Runco XP-50, XP-65 operation manual Dwaovlon

Page 71

Serial Communications

Table 6-1. Serial Commands

ASCII

 

 

Hex

Description

 

 

 

 

 

 

DWA:OVLON

44 57 41 3A

4F

56

4C 4F 4E

Advanced PIP mode (ON)

 

 

 

 

 

 

DWA:PIN0

44 57 41 3A

50

49

4E 30

The location of the sub picture (lower

 

 

 

 

 

right)

 

 

 

 

 

 

DWA:PIN1

44 57 41 3A

50

49

4E 31

The location of the sub picture (lower

 

 

 

 

 

left)

 

 

 

 

 

 

DWA:PIN2

44 57 41 3A

50

49

4E 32

The location of the sub picture (upper

 

 

 

 

 

left)

 

 

 

 

 

 

DWA:PIN3

44 57 41 3A

50

49

4E 33

The location of the sub picture (upper

 

 

 

 

 

right)

 

 

 

 

 

 

DWA:PIP

44 57 41 3A

50

49

50

Dual Picture mode (Picture in Picture)

 

 

 

 

 

 

DWA:POP

44 57 41 3A

50

4F

50

Dual Picture mode (Picture out Pic-

 

 

 

 

 

ture)

 

 

 

 

 

 

DWA:SWP

44 57 41 3A

53

57

50

Swap main picture and sub picture

 

 

 

 

 

when PIP mode

 

 

 

 

 

 

DWA:TWN

44 57 41 3A

54

57

4E

Dual Picture mode (Picture and Pic-

 

 

 

 

 

ture)

 

 

 

IMS:PC1

49 4D 53 3A 50 43 31

Input select (PC1) (Main Picture when

 

 

 

 

 

PIP mode)

 

 

 

IMS:SL1A

49 4D 53 3A 53 4C 31 41

Input select (SLOT1A) (Main Picture

 

 

 

 

 

when PIP mode)

 

 

 

IMS:SL1B

49 4D 53 3A 53 4C 31 42

Input select (SLOT1B) (Main Picture

 

 

 

 

 

when PIP mode)

 

 

 

IMS:SL2A

49 4D 53 3A 53 4C 32 41

Input select (SLOT2A) (Main Picture

 

 

 

 

 

when PIP mode)

 

 

 

IMS:SL2B

49 4D 53 3A 53 4C 32 42

Input select (SLOT2B) (Main Picture

 

 

 

 

 

when PIP mode)

 

 

 

IMS:SL3

49 4D 53 3A 53 4C 33

Input select (SLOT3) (Main Picture

 

 

 

 

 

when PIP mode)

 

 

 

 

 

 

ISS:PC1

49 53 53 3A

50

43

31

Sub Picture Input Select (PC1)

 

 

 

 

 

ISS:SL1A

49 53 53 3A

53

4C 31 41

Sub Picture Input Select (SLOT1A)

 

 

 

 

 

ISS:SL1B

49 53 53 3A

53

4C 31 42

Sub Picture Input Select (SLOT1B)

 

 

 

 

 

ISS:SL2A

49 53 53 3A

53

4C 32 41

Sub Picture Input Select (SLOT2A)

 

 

 

 

 

ISS:SL2B

49 53 53 3A

53

4C 32 42

Sub Picture Input Select (SLOT2B)

 

 

 

 

 

ISS:SL3

49 53 53 3A

53

4C 33

Sub Picture Input Select (SLOT3)

 

 

 

 

 

OSP:RCM0

4F 53 50 3A 52

43

4D 30

Remote Control User Level = Off

OSP:RCM1

4F 53 50 3A 52

43

4D 31

Remote Control User Level = User1

OSP:RCM2

4F 53 50 3A 52

43

4D 32

Remote Control User Level = User2

OSP:RCM3

4F 53 50 3A 52

43

4D 33

Remote Control User Level = User3

 

 

 

 

 

 

CinemaWall XP-50/XP-65 Installation/Operation Manual

57

Image 71
Contents XP-50 XP-65 Page RuncoCare Standard Features RuncoCare Standard Two Year Limited WarrantyRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part Page Table of Contents Operation Maintenance and TroubleshootingSpecifications Appendix A. Default SettingsList of Figures List of Figures Xiv About This Manual IntroductionDegrade performance or cause a malfunction Using This ManualCertain features Significance. They also provide supplemental informationKey Features and Benefits Description, Features and BenefitsOptional Accessories XP-50 CinemaWall at a Glance Controls and IndicatorsControls and Functions Display Stand XP-506 XP-65 ConnectorsPower Input Surround button CinemaWall Remote ControlControls and Functions Other surfaces InstallationRemote Control Step Procedure For Details, refer to Quick SetupInstallation specialist Installation Considerations Ventilation Ambient LightOther Considerations Components to Connecting SourceConnections to CinemaWallRCA-BNC adapter plug Analog RGB Connections Connection Connecting External Speakers OptionalConnector Pin Assignments RS-232 ControllerAC Power Connection Operation Turning on the Power Changing the OSD LanguageSetting the Day and Time Setting the Computer Display Properties Aspect ratio selection is saved independently for each input Selecting an Input Source Changing the Aspect Ratio149 169Edges of the screen 43 431 linearly scalesSource image horizon Played at the left and rightActivating PIP Swapping the Main PIP Images Using Picture-In-Picture PIPChanging the PIP Window Position Using the On-Screen MenusSelecting a PIP Target Screen or Input SourcePOS./SIZE Options Picture This control is not available when Picture Menu is set to Typical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness POS./SIZE CinemaWall memorizes position and size settings separatelyFrequency is 108 MHz or greater Options menu refer to page 50 is set to OnSound Or 1080p and the Aspect Ratio is set to 169 refer toSET UP Signal Screensaver Is active On the remote control unit, or cycle power to the CinemaWall Order to activate multi-display mode, you must first set Refer to Changing the OSD Language onOn hides joints between displays C D Insert cannot be used when Transparency is set to on Transparency cannot be used when Insert is set to onPresent Time Setup Refer to Setting the Day and Time on Command Timer refer toDVD3 Operation Refer to Return ChangeCurrently active Level see belowPicture menu is set to Warm When using multiple displays such as in a video wall RuncoSome cases, power is transmitted to the slot when MULTI-DISPLAY is activeOn page 21, the Clock Display setting has no effect Using Digital ZoomDuring the delay period, the power indicator flashes green Operation Cleaning the Screen Maintenance and TroubleshootingCleaning Cleaning the Display Panel Body and Remote ControlSymptom Possible Causes Solution Troubleshooting TipsExamples Command 3 bytes Parameter 3 bytesCommand 3 bytes Parameter 6 bytes Serial CommunicationsHex Description Serial CommandsDwaovlon OSPSCR0 CinemaWall Specifications SpecificationsCinemaWall Model XP-50 Dimensions with Optional Table Stand CinemaWall DimensionsCinemaWall Model XP-65 Dimensions with Optional Table Stand Supported Timings Supported Signal Timings by Input Specifications Table A-1. Runco Factory Default Settings for CinemaWall Appendix A. Default SettingsDefault Settings Page 020-0970-00 Rev. B March