2 INSTALLATION

2.4.2Table-Top Installation

The Multichannel Media Converter is shipped with four (4) rubber feet for optional installation on table or other flat, stable surface.

CAUTION: Do not place the Multichannel Media Converter on active, heat generating equipment and avoid placing other devices on top of the Multichannel Media Converter. Failure to observe this caution could cause Multichannel Media Converter to fail.

1.Select a level, secure surface in a well-ventilated area.

2.Remove the adhesive protective sheet from the rubber feet

(provided) and affix the feet to the corners on the bottom of the Multichannel Media Converter, approximately 1 centimeter from each edge.

3.Set the Multichannel Media Converter securely upright on the stable surface.

MULTICHANNEL MEDIA CONVERTER

2.7

Image 17
Contents Multichannel Media Converter Compliance Information Table of Contents Operation Introduction AC Power Supply Module/Optional Redundant AC PowerMedia Converter Channels Multichannel Media Converter ModelsIntroduction Reset ButtonSerial Port Multichannel Media Converter Management ModuleManagement Module LEDs Network RJ-45 Connection Multiport Management Software at RemotePage Connecting Channel Ports to Network InstallationPreparing the Site Unpacking METTF10xx, MFETF10xx Equipment Installation Setting Management Module Jumper Installing Optional Redundant Power Supply ModuleInstalling Power Supply Module Standard Rack Installation Installing Multichannel Media Converter at SiteTable-Top Installation Powering the Multichannel Media Converter Setting Full-Duplex/Half-Duplex Configuration Switches Connecting Channel Ports to NetworkSetting FDX/HDX Channel Configuration Switches Testing Fiber Links Installing Fiber-optic CableInstalling Cable Norm Test Installing Twisted-Pair Copper CableNone Setting Network Management ParametersEthernet Parameters METTF10xx, MFETF10xx TCP/IP Installing Multiport Management Software at Remote NMSPage Operation Power Supply and Link Test Switch LEDs Using Status LEDsManagement LEDs Channel LEDsOperation Using a Terminal EmulatorUsing Terminal Emulator Operation Standalone Win32* Systems Using Multiport Management Software at Remote NMSMain Power Supply Status is green for OK or red for fail Page Maintenance Is Multichannel Media Converter Receiving Power? Fault Isolation and RecoveryAre Channel Links Good? Fault Isolation and Recovery Replacing Management Module Hardware Replacement ProceduresReplacing AC Power Supply Module Power Technical SpecificationsPage Fiber-Optic Cable Channel Cable SpecificationsMETTF1011 -120 MFETF1011