APPENDIX B
CHANNEL CABLE SPECIFICATIONS
The physical characteristics of the media cable must meet or exceed
IEEE 802.3 specifications.
Fiber-Optic Cable
Multimode: | 62.5 / 125 µm multimode fiber |
| Optional: |
| 100 /140 µm multimode fiber |
| 85 /125 µm multimode fiber |
| 50 /125 µm multimode fiber |
Singlemode: | 9 µm singlemode fiber |
Twisted-Pair Copper Cable
Use shielded
Category 3
Gauge | 24 to 22 AWG |
Attenuation | 28 dB/1000’ @ 10 MHz |
Differential Characteristic Impedance | 100 Ω ±10% @ 10 MHz |
Category 5
Gauge | 24 to 22 AWG |
Attenuation | 20 dB/1000’ @ 10 MHz |
| 22.0 dB /100m @ 100 MHz |
Differential Characteristic Impedance | 100 Ω ±10% @ 10 MHz |
NOTE: The active pairs are pins 1 & 2 and pins 3 & 6. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange)
Straight Through Cable
Twisted
Pair #1
Twisted
Pair #2
Connectors for unlike devices
for the active pins.
Crossover Cable
Twisted
Pair #1
Twisted
Pair #2
Connectors for like devices
When connecting the Multichannel Media Converter
When connecting the Multichannel Media Converter
MULTICHANNEL MEDIA CONVERTER | B.1 |
|