Transition Networks DVP 5140K manual Fault Isolation and Recovery

Page 38

Fault Isolation and Recovery

4.Is Management Connection Good?

If the Management READY LED is OFF:

Ensure that the Management Module is seated firmly in the Multichannel Media Converter.

Ensure that the Management Module is configured properly (See Section 3 INSTALLATION).

If the configuration menu isn’t readable or doesn’t appear at all:

Ensure that the serial cable is good.

Ensure that the terminal settings are good.

If there is no SNMP response from the manager:

Check the IP address on the configuration menu.

Try to use the "ping" command.

If there is no “ping”

Check the Ethernet cable.

Check the LNK LED.

If there are no traps:

Check the SNMP manager IP address in the trap destination on the configuration menu.

If the Multichannel Media Converter doesn’t appear in the MIB browser:

Ensure that the Multichannel Media Converter MIB file is copied to the proper location in the remote Network Management Station.

Ensure that the MIBs are compiled with the new file.

4.Is the Management Module connected to an active 10BASE-T Ethernet port?

Ensure that the Management LNK LED indicator is illuminated, indicating a good link.

Ensure that the Management REC LED indicator is blinking, indicating that the Management Module is receiving data.

Failure may indicate that Multichannel Media Converter Management Module connection to the network has failed.

Verify the integrity of the 10BASE-T hub/switch port to which the Multichannel Media Converter is attached.

Verify the integrity of the 10BASE-T twisted-pair Ethernet cable that leads from the hub/switch to the Multichannel Media Converter.

Contact TRANSITION Networks Technical Support.

4.4

METTF10XX, MFETF10XX

Image 38
Contents Multichannel Media Converter Compliance Information Table of Contents Operation AC Power Supply Module/Optional Redundant AC Power IntroductionMultichannel Media Converter Models Media Converter ChannelsReset Button IntroductionSerial Port Multichannel Media Converter Management ModuleManagement Module LEDs Multiport Management Software at Remote Network RJ-45 ConnectionPage Installation Connecting Channel Ports to NetworkPreparing the Site Installation Unpacking METTF10xx, MFETF10xx EquipmentInstalling Optional Redundant Power Supply Module Setting Management Module JumperInstalling Power Supply Module Installing Multichannel Media Converter at Site Standard Rack InstallationTable-Top Installation Powering the Multichannel Media Converter Setting Full-Duplex/Half-Duplex Configuration Switches Connecting Channel Ports to NetworkSetting FDX/HDX Channel Configuration Switches Testing Fiber Links Installing Fiber-optic CableInstalling Cable Installing Twisted-Pair Copper Cable Norm TestSetting Network Management Parameters NoneEthernet Parameters METTF10xx, MFETF10xx Installing Multiport Management Software at Remote NMS TCP/IPPage Operation Management LEDs Using Status LEDsPower Supply and Link Test Switch LEDs Channel LEDsUsing a Terminal Emulator OperationUsing Terminal Emulator Operation Using Multiport Management Software at Remote NMS Standalone Win32* SystemsMain Power Supply Status is green for OK or red for fail Page Maintenance Fault Isolation and Recovery Is Multichannel Media Converter Receiving Power?Are Channel Links Good? Fault Isolation and Recovery Hardware Replacement Procedures Replacing Management ModuleReplacing AC Power Supply Module Technical Specifications PowerPage Channel Cable Specifications Fiber-Optic CableMETTF1011 -120 MFETF1011