Fluke 80 Series V manual Electrical Symbols, General Specifications

Page 12

80 Series V

Calibration Manual

Electrical Symbols

Electrical symbols used on the Meter and in this manual are explained in Table 1.

Table 1. Electrical Symbols

B

AC (Alternating Current)

J

Earth ground

 

 

 

 

F

DC (Direct Current)

I

Fuse

 

 

 

 

X

Hazardous voltage.

P

Conforms to European Union directives

 

 

 

 

W

Risk of Danger. Important

$

Conforms to relevant Canadian

 

information. See Manual.

 

Standards Association directives

M

Battery

T

Double insulated

 

 

 

 

R

Continuity test or continuity beeper

E

Capacitance

tone.

 

 

 

 

 

t

Underwriters Laboratories

G

Diode

 

 

 

 

 

IEC overvoltage category III

 

IEC overvoltage category IV

 

CAT III equipment is designed to

 

 

 

CAT IV equipment is designed to protect

 

protect against transients in

 

 

 

against transients from the primary

CAT III

equipment in fixed-equipment

CAT IV

supply level, such as an electricity meter

installations, such as distribution

or an overhead or underground utility

 

panels, feeders and short branch

 

 

 

service.

 

circuits, and lighting systems in

 

 

 

 

 

large buildings.

 

 

 

 

 

 

s

Inspected and licensed by TÜV Product Services.

 

 

 

 

 

Specifications

General Specifications

Maximum Voltage between any Terminal and Earth Ground: 1000 V rms

WFuse Protection for mA or A inputs: 44/100 A, 1000 V FAST Fuse

WFuse Protection for A input: 11 A, 1000 V FAST Fuse

Display: Digital: 6000 counts updates 4/sec; (Model 87 and 88 also has 19,999 counts in high-resolution mode).

Analog Bargraph: 33 segments, updates 40/sec. Frequency: 19,999 counts, updates 3/sec at > 10 Hz

Temperature: Operating: -20 °C to +55 °C; Storage: -40 °C to +60 °C

Altitude: Operating: 2000 m; Storage: 10,000 m

Temperature Coefficient: 0.05 x (specified accuracy)/ °C (< 18 °C or > 28 °C)

Electromagnetic Compatibility: In an RF field of 3 V/m total accuracy = specified accuracy + 20 counts

Except: 600 A dc range total accuracy=specified accuracy + 60 counts. Temperature not specified.

Relative Humidity: 0 % to 90 % (0 °C to 35 °C); 0 % to 7 0% (35 °C to 55 °C)

Battery Type: 9 V zinc, NEDA 1604 or 6F22 or 006P

Battery Life: 400 hrs typical with alkaline battery (with backlight off)

Vibration: Per MIL-PRF-28800 for a Class 2 instrument

Shock: 1 Meter drop per IEC 61010-1:2001

Size (HxWxL): 1.25 in x 3.41 in x 7.35 in (3.1 cm x 8.6 cm x 18.6 cm)

Size with Holster and Flex-Stand:2.06 in x 3.86 in x 7.93 in (5.2 cm x 9.8 cm x 20.1 cm)

Weight: 12.5 oz (355 g)

Weight with Holster and Flex-Stand: 22.0 oz (624 g)

Safety: Complies with ANSI/ISA S82.01-2004, CSA 22.2 No. 1010.1:2004 to 1000 V Overvoltage Category III, IEC

4

Image 12
Contents Series Lifetime Limited Warranty Table of Contents Series List of Tables Series List of Figures Series Introduction Contacting FlukePrecautions and Safety Information XWWarningDigital Multimeter Electrical Symbols SpecificationsGeneral Specifications Electrical SymbolsDetailed Specifications Model 87 AC Voltage Function SpecificationsModels 83 and 88 AC Voltage Function Specifications Current Function Specifications Function Range Resolution Accuracy ModelCapacitance and Diode Function Specifications Frequency Counter Specifications Models 87Frequency Counter Specifications Model Frequency Counter Sensitivity and Trigger LevelsElectrical Characteristics of the Terminals MIN MAX Recording SpecificationsBasic Maintenance Cleaning the MeterOpening the Meter Case Accessing the PCA and Replacing the LCD Opening the Meter, Battery and Fuse ReplacementRemoving LCD Mask to Access LCD Reassembling the Meter CaseReplacing the Battery Testing Fuses and Current CircuitryRequired Equipment Replacing the FusesPerformance Tests Testing the Fuses Testing the DisplayBasic Operability Tests Trig YCAL Testing the Pushbuttons Testing Meter AccuracyAccuracy Tests 600 Ω 330 Ω Use 2 wire Comp 328.5 to 329.1 to Ohms Testing the Inductive Pickup 88 Only Press backlight button Backlight offDegrees Setup for Inductive Pickup Test Waveform for Inductive Pickup Test Calibration Adjustment Calibration Adjustment CounterCalibration Adjustment Password Restoring the Default Password Calibration Adjustment Procedure Meter Buttons Used in the Calibration StepsMA / UA Service and Parts Series V Final Assembly Ref Des Description Part Qty NumberSeries V Final Assembly