Fluke 80 Series V manual Introduction, Contacting Fluke

Page 9

Introduction

XW Warning

To avoid shock or injury:

Read “Precautions and Safety Information” before performing the verification tests or calibration adjustment procedures documented in this manual.

Do not perform the verification tests or calibration adjustment procedures described in this manual unless you are qualified to do so.

The information provided in this manual is for the use of qualified personnel only.

WCaution

The 80 Series V Digital Multimeters contains parts that can be damaged by static discharge.

Follow the standard practices for handling static sensitive devices.

The 80 Series V Calibration Manual provides the following information:

Safety information

Specifications

Basic maintenance (cleaning, replacing the battery and fuses)

Performance test procedures

Calibration adjustment procedures

Replaceable parts

For complete operating instructions, refer to the 80 Series V or 88 Series V Users

Manual.

Contacting Fluke

To contact Fluke or locate the nearest Service Center, call one of the following telephone numbers:

USA: 1-888-44-FLUKE (1-888-443-5853)

Canada: 1-800-36-FLUKE (1-800-363-5853)

Europe: +31 402-675-200

Japan: +81-3-3434-0181

Singapore: +65-738-5655

Anywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at www.fluke.com. To register your product, visit register.fluke.com

1

Image 9
Contents Series Lifetime Limited Warranty Table of Contents Series List of Tables Series List of Figures Series Contacting Fluke IntroductionXWWarning Precautions and Safety InformationDigital Multimeter Specifications Electrical SymbolsGeneral Specifications Electrical SymbolsDetailed Specifications Model 87 AC Voltage Function SpecificationsModels 83 and 88 AC Voltage Function Specifications Function Range Resolution Accuracy Model Current Function SpecificationsFrequency Counter Specifications Models 87 Capacitance and Diode Function SpecificationsFrequency Counter Specifications Model Frequency Counter Sensitivity and Trigger LevelsMIN MAX Recording Specifications Electrical Characteristics of the TerminalsBasic Maintenance Cleaning the MeterOpening the Meter Case Opening the Meter, Battery and Fuse Replacement Accessing the PCA and Replacing the LCDReassembling the Meter Case Removing LCD Mask to Access LCDTesting Fuses and Current Circuitry Replacing the BatteryReplacing the Fuses Required EquipmentPerformance Tests Testing the Display Testing the FusesBasic Operability Tests Trig YCAL Testing the Pushbuttons Testing Meter AccuracyAccuracy Tests 600 Ω 330 Ω Use 2 wire Comp 328.5 to 329.1 to Ohms Press backlight button Backlight off Testing the Inductive Pickup 88 OnlyDegrees Setup for Inductive Pickup Test Waveform for Inductive Pickup Test Calibration Adjustment Calibration Adjustment CounterCalibration Adjustment Password Restoring the Default Password Meter Buttons Used in the Calibration Steps Calibration Adjustment ProcedureMA / UA Series V Final Assembly Ref Des Description Part Qty Number Service and PartsSeries V Final Assembly