Setup menus
USER menu | <INTERFACE> | |
|
|
|
No./Item |
| Description |
|
| |
|
| |
200 | This selects whether two or more VTRs are to | |
| be operated in synchronization. | |
PARA RUN |
|
|
| 0000 | DIS : No operation in synchronization |
| 0001 | ENA : Operation in synchronization |
| <Note> | |
| When operating two or more VTRs in | |
| synchronization, set all the VTRs to ENA. | |
|
| |
201 | This selects whether the REMOTE (9P) | |
| connector functions when the CONTROL | |
9P SEL | switch has been set to REMOTE. | |
| 0000 | OFF : Connector does not function. |
| 0001 | ON : Connector functions. |
|
| |
202 | This sets the ID information to be returned to | |
| the controller. | |
ID SEL |
|
|
| 0000 | OTHER |
| 0001 DVCPRO | |
| 0002 | ORIG |
| <Notes> | |
| OID information of any VTR except for the | |
| DVCPRO’s is set in OTHER. | |
| OThe ORIG setting should only be used when a | |
| Panasonic controller | |
| separately) is connected. | |
|
| |
203 | This selects whether the PARALLEL (25P) | |
| connector functions when the CONTROL | |
25P SEL | switch has been set to REMOTE. | |
| 0000 | OFF : Connector does not function. |
| 0001 | ON : Connector functions. |
|
| |
204 | This selects whether the | |
| functions when the CONTROL switch has | |
RS232C SEL | been set to REMOTE. | |
| 0000 | OFF : Connector does not function. |
| 0001 | ON : Connector functions. |
|
| |
205 | These settings are for selecting the | |
| communication speed (baud rate). | |
BAUD RATE |
|
|
| 0000 | 300 |
| 0001 | 600 |
| 0002 | 1200 |
| 0003 | 2400 |
| 0004 | 4800 |
| 0005 | 9600 |
|
| |
206 | These settings are for selecting the | |
| data length. (Unit: bit) | |
DATA |
|
|
LENGTH | 0000 | 7 |
| 0001 | 8 |
|
| |
207 | These settings are for selecting the | |
| stop bit length. (Unit: bit) | |
STOP BIT |
|
|
| 0000 | 1 |
| 0001 | 2 |
|
|
|
No./Item |
| Description | ||
|
|
|
| |
|
|
|
| |
208 |
|
| These settings are for selecting the none, odd | |
|
|
| or even for the | |
PARITY |
|
| ||
|
|
| 0000 | NON : |
|
|
| Parity bit is not used. | |
|
|
| 0001 | ODD: |
|
|
| An odd number of bits is used for the parity | |
|
|
| system. | |
|
|
| 0002 | EVEN: |
|
|
| An even number of bits is used for the parity | |
|
|
| system. | |
|
|
|
| |
209 |
|
| These settings are for selecting whether the | |
|
|
| ACK code is to be returned when a command | |
RETURN ACK | is received from | |||
|
|
| 0000 | OFF : ACK code is not returned. |
|
|
| 0001 | ON : ACK code is returned. |
|
|
|
| |
210 |
|
| For selecting the method used to detect the | |
|
|
| STANDBY COMMAND signal input at the | |
25P STBY | PARALLEL (25P) connector. | |||
CMD |
|
| ||
|
|
| 0000 | OFF/ON : |
|
|
| Each time active signals are detected, the | |
|
|
| STANDBY ON or STANDBY OFF mode is | |
|
|
| selected alternately. | |
|
|
| 0001 | ON : |
|
|
| When active signals are detected in the | |
|
|
| STANDBY OFF mode, the unit is transferred to | |
|
|
| the STANDBY ON mode. | |
|
|
| Nothing happens if they are detected during an | |
|
|
| operation in the STANDBY ON mode. | |
|
|
|
| |
211 |
|
| This selects whether the PARALLEL (25P) | |
|
|
| connector is to function when the CONTROL | |
LOCAL 25P | switch is at the LOCAL position. | |||
|
|
| 0000 | OFF : Connector does not function. |
|
|
| 0001 | ON : Connector functions. |
|
|
|
| |
212 |
|
| For selecting the remote control connector to | |
SD955 | ||||
|
|
| control the slave when the unit is used as the | |
MASTER | master during | |||
PORT |
|
| ||
|
|
| 0000 | IN/OUT : The IN/OUT connector is used. |
|
|
| 0001 | OUT : The OUT connector is used. |
|
|
| <Note> | |
|
|
| This menu item takes effect only when the | |
|
|
| CONTROL switch has been set to the LOCAL | |
|
|
| position. | |
|
|
|
|
|
The underlined items indicates the initial setting.