OTHERS | – Warning display – |
When an anomaly occurs, this unit automatically identifies the cause and displays an error- coded warning message on the monitor.
If the unit is in a state needing rectification, or if an operation error has occurred, an alarm display will be shown on the monitor.
Warning display
|
|
|
|
|
|
3 2 K C H – 1 / 2 |
|
| 0 m i n | ||
|
|
|
|
| |
| W A R N I N G | 7 0 0 1 |
| ||
| D R UM MO T O R | F A I L U R E |
| ||
1 0 / 1 0 / 0 2 |
|
| S T A N D B Y - O F F | ||
1 2 : 0 0 : 0 0 | T C R | 0 2 : 0 0 : 0 0 : 0 0 | |||
|
|
|
|
|
|
Alarm display
|
|
|
|
3 2 K C H – 1 / 2 | 0 m i n | ||
|
|
|
|
H E A D C L E A N I N G R E Q U I R E D !
1 0 / 1 0 / 0 2 | S T A N D B Y - O F F |
1 2 : 0 0 : 0 0 | T C R 0 2 : 0 0 : 0 0 : 0 0 |
Alarm display (Displayed regardless of the DISPLAY mode)
Display | Status | Action |
|
|
|
LOW VOLTAGE | The DC power voltage is low. | Please check the power voltage. |
| The unit will eventually go into the POWER OFF |
|
| mode if operation is continued. |
|
|
|
|
HEAD CLEANING | The video head is dirty. If the head is clogged, it | Please clean it with the dedi- |
REQUIRED! | will be detected and the alarm message will be | cated |
| displayed during the PLAYBACK mode. When | (☞ Page 8) |
| the STOP mode is engaged or when the cas- | If the message persists despite |
| sette is ejected, the display will go off. | cleaning, it could be due to bad |
| When the head clog is cleared, the message | recording condition, bad tape or |
| will disappear. | lifespan of the head. |
|
|
|
•For alarm messages displayed upon operation errors or when the unit is in a poor working condition (e.g. dirty head), refer to page 22.