LG Electronics 37LD330H, 32LD330H setup guide LT2002 Cloning Notes, Different Master TV Setups

Page 27

Cloning Procedures (Cont.)

Learning / Teaching a Master TV Setup using an LT2002 Clone Programmer

Warning: Do not connect a clone programmer to a PPV card installed in the Master or Target TVs, as this will damage the clone programmer and the PPV card.

Cloning is accomplished using the TV/clone programmer MPI ports for communication (see figure).

LT2002 Cloning Notes

• Read the IMPORTANT CLONING

INFORMATION on page 23 before

beginning any cloning procedures.

• A slow flashing green light indicates

that there are communication

 

MPI

Antenna

Cable

 

or CATV

 

 

problems between the TV and the

 

LT2002 clone programmer. If this is

 

the case, check for a damaged

 

cable, poor contacts, or other

 

connection troubles.

If the status indicator is red, the

 

LT2002 batteries are low and

 

should be replaced. Install four (4)

 

high-quality alkaline AA batteries.

Learning and Teaching is only

 

possible between identical model

 

TVs; however, the LT2002 clone

 

programmer can store up to three

 

different Master TV Setups.

THE CLONE HAS CONTROL OF THE TV

THE CLONE IS VERSION XX

THE TV IS VERSION XX

THE SW IS REViSION XX

CLONE CLOCK = XX:XX

TV

CLOCK = XX:XX

- PRESS ANY KEY TO CONTINUE

Ferrite Core (TDK, ZCAT 2035-0930)

LT2002 Clone Programmer

Connect cable to

 

 

 

 

 

 

TV MPI Jack and

 

Status

follow on screen

 

instructions

 

Indicator

 

MPI

 

 

 

 

 

 

 

 

 

 

 

Reset

 

 

 

 

Color

 

• green

 

battery ok

 

• red

 

battery low

 

 

 

Blink pattern

 

 

• slow

 

power on

no communications

heartbeat power on communications ok

®

QuickSet II Programmer

LT2002

ZENITH ELECTRONICS CORPORATION, LINCOLNSHIRE, ILLINOIS, USA

Learn Setup from Master TV

1.Ensure the Master TV is set up completely and in Pass-through Mode.

2.If an analog channel is not available, direct tune the TV to an Aux source, or select an Aux source, such as AV-1, from the Input Menu. Then, plug one end of the MPI cable into the TV MPI port.

3.If there is a good connection after the LT2002 is connected to the TV MPI port, “THE CLONE HAS CONTROL OF THE TV” message will appear on the TV screen. Press any key on the Installer Remote to access the LT2002 Clone Selection Menu.

4.Press 1 on the Installer Remote to select LEARN FROM TV from the Clone Selection Menu; then press ENTER to proceed to the Memory Bank Selec- tion Menu (see sample screen on next page).

5.Press 1, 2, or 3 on the Installer Remote to select the clone Memory Bank in which to store the Master Setup. Then, press ENTER.

Note: If you choose a Memory Bank that already has a Master device’s setup programmed into it, that setup will be overwritten by the new Master TV Setup.

(Continued on next page)

THE CLONE HAS CONTROL OF THE TV

THE CLONE IS VERSION XX

THE TV IS VERSION

XX

THE SW IS REVISION

XX

CLONE CLOCK = XX:XX

 

TV

CLOCK = XX:XX

 

-PRESS ANY KEY TO CONTINUE.

-DISCONNECT CLONE WHEN DONE.

CLONE SELECTION MENU

(1) LEARN FROM TV

(2)TEACH TO TV

(3)SET CLONE CLOCK FROM TV

(4)SET TV CLOCK FROM CLONE

(5)DISPLAY TV SETUP

(6)DISPLAY CLONE SETUP

-TO CHANGE MENU ITEMS, PRESS CHANNEL KEYS OR DIGITS.

-TO EXECUTE ITEM, PRESS ON/OFF, POWER, OR ENTER.

206-4185

27

Image 27
Contents Copyright 2011, LG Electronics U.S.A., Inc 206-4185 Rev aFor Customer Support/Service, please call­ Disconnect Device Power CordOverloading GroundingTransporting Product CleaningOutdoor Antenna Grounding Antenna Grounding According to NEC, ANSI/NFPATable of Contents Setup Checklist / Commercial Mode Setup Overview Setup ChecklistCommercial Mode Setup Overview Help ProCentric TV Interactive Menu FeaturesChannel Guide InformationMPI LD330H Rear Jack PanelComponent AUDIO/VIDEO2 Input Side Connections Panel / RF Antenna ConnectionSide Connections Panel RF Antenna ConnectionCloning Installer OverviewInstaller Remote Installing Batteries in Installer RemoteInstaller Remote Control Typical Key Functions VOLMenu Run Auto Tuning Channel Search Commercial Mode Setup for Master TVSet Installer Menu items Set up TV featuresLock the channel lineup Verify the TV setupExiting the Installer Menu and Activating Updates Installer MenuAccessing the Installer Menu Using the Installer MenuBrief Description of Function and Comments Installer Menu Items 000 throughCH not Avble Installer Menu Items 073 throughDetailed Descriptions of Installer Menu Items Installer SequenceMute Disable Poll Rate Sleep TimerFeature Level Caption LockRear RGB EN. Rear RGB Enable DIS. CH-TIME Disable Channel-TimeEN. CH-T COL. Enable Channel-Time Custom Color Chksm Error Checksum ErrorAtsc Band Atsc Tune ModeProcentric Back LightingTV Setup Menus Overview To perform channel editing/labeling Editing/Adding Channel Icons and/or LabelsCloning Overview / Clonable Menu Features Clonable Menu FeaturesBefore you begin cloning USB Cloning Notes Cloning ProceduresLearn Setup from Master TV Teach Master TV Setup to Target TVTLL-1100A Cloning Notes TLL-1100A Clone Programmer TV LinkCable Optional Set the Clock LT2002 Cloning Notes Different Master TV SetupsFrom previous TV Setup Menus FTG Mode of OperationFTG Mode Overview Determining the TV Operating ModeFTG Mode of Operation Teaching FMA Configuration to a TV Learning an FMA Configuration File from a TV Optional Manual Configuration / Setup for a TV Print MAP FTG Configuration Application Utilities OverviewFTG Channel Map Configuration Utility EDIT/ADD MAPADD UpdateFTG Channel Map Editor DeleteFTG Installer Menu Configuration Utility Installer DefaultsHOSPITAL-GRADE TV only FMA Configuration Utility FMA Configuration ListNEW/OPEN/SAVE Upgrading TV/PTC Software Checking the Software VersionsDownloading a Splash Screen Image Splash Screen Image File GuidelinesStatic Reference Power Consumption SettingsCamport Operation FTG or PPV Reference TV Camport Auto Sense OperationCamport Side Video Functionality Control Camport Operation Stand-aloneEnable Reference TV Aux Input ConfigurationReference Resetting a TV to Pass-through Mode General Troubleshooting TroubleshootingController Quick Check Troubleshooting Flow ChartCommercial Mode Check / FTG Operation Troubleshooting FTG Operation TroubleshootingSymptom Possible Causes Solutions Clone Programmer Clone Programmer TroubleshootingReset Clone Programmer After Static Shock Symptom Possible Causes Possible SolutionsGlossary of Terms Document Revision History / Notes Document Revision HistoryDate Description May Revision a New document For Customer Support/Service, please call­