Firstech, LLC CM1000A, CM3 SERIES, CM4200 manual CM-3300 Wiring Detail

Page 28

CM-3300 WIRING DETAIL

CONNECTOR 1

Pin 1 Brown- Siren 12-volt (+) positive output. This wire will provide a 30 or 60 second

(+) positive output for the external siren. (Note: Factory default is 30 seconds.)

Pin 2 Green/White- Parking light (+) positive output. Connect this wire to the (+) positive parking light wire generally at the parking light switch or behind the fuse box. The proper wire will test 12-volts (+) positive when the parking light switch is in the on position.

Pin 1 Red- Constant 12-volt (+) positive power input for the control module. This wire must be connected to a constant 12-volt (+) positive source. The proper wire will test 12-volt (+) positive with the key in the off position, while key is in the on position and during crank.

Pin 4 Black- Ground (-) negative input. This wire will connect to chassis ground.

CONNECTOR 2

Pin 1 Green/White- Parking light 250mA (-) negative output. This is an optional output that will provide a (-) negative output with parking light flash.

Pin 2 White- Horn honk 250mA (-) negative output. This is an optional output that will provide a 30 or 60 second (-) negative pulse when the alarm is triggered or during panic.

Pin 3 Yellow- Aux 1- 250mA (-) negative output. This is an optional output that will provide a pulse, latch or a timed pulse output. (Note: Options programmer is required to program a timed pulse output.)

Pin 4 Yellow/White- Aux 2- 250mA (-) negative output. This is an optional output that will provide a pulse, latch or a timed pulse output. (Note: Options programmer is required to program a timed pulse output.)

Pin 5 Violet- 250mA (-) negative output when armed. This wire will provide a (-) negative output when system is locked and armed. (Note: This wire can also be used to trigger after-market L.E.D. kits and other after-market accessories. Output must be diode isolated when used to trigger after-market accessories.)

- 28 -

Image 28
Contents Master Install Guide CM3 Series CM4200 CM1000A Page Table of Contents Install Checklist Remote Programming Procedures Page Remote Programming Procedures 1WFM6R 2WFMR-S,2WAMR, 2WFMR, and 2W900FMRPage Page Common Procedures Page Dipswitch and Jumper Settings Antenna MountingAdjusting Siren Volume Adjusting Shock Sensor SensitivityLittle Green Loop Programming Tach / Alternator Sensing Tach sensingDiagnosing Remote Start Problems Alternator sensingPage Control Modules Page CM3000 Wiring Diagram CN1 CN2 CN3 CN4 CN5 CN6 CN7CM-3000 Wiring Detail Connector Pin 1 Not used Pin 6 Not used Pin 8 Not usedPre-wired Shock Sensor Pre-wired Antenna Cable Page CM3300 Wiring Diagram CN1CM-3300 Wiring Detail Connector Pre-wired L.E.D Pre-wired Remote Paging Sensor or R.P.S Page CM4200 Wiring Diagram JM1CM-4200 Wiring Detail Connector Pin 1 Not used Optional Temperature sensor Page CM1000A Wiring Diagram CM-1000A Wiring Detail Connector Pre-wired L.E.D Option Programming Page Option Programming 1WAM4R, 1WFM4R, 1W900FM4R, and 1WSS4R R500A CM1000A 1WFM6R 2WFMR-S, 2WAMR, 2WFMR, and 2W900FMR2WSSR CM3 Series Option ProgrammerWay 4 Button Remotes All 2-Way Remotes CM3000 Option Menu Feature CM3300 Option Menu Feature CM4200 Option Menu Sec Anti-Jacking Ign Kill Enabled Options Explained In Detail CM3000-3300-4200 CM3000 CM4200 Page Additional Programming Page Installation Assistance Page Frequently Asked Questions / Troubleshooting Vehicle will remote start when disarmed, but not when armed Do I have to hook up both 12v+ wires?How do I upgrade my current install to a higher end model? Vehicle starts then shuts down 3 times in a rowCommon Diagrams Adding Door Actuators Trunk Release Transponder Passlock Passlock Aftermarket Turbo Timer with Parking Brake Trigger Starter Kill Relay Installation Page Page Page Accessory Manuals Page Stand Alone Mode OP500 Option ProgrammerConnector 2 Output Connector 1 InputChannel Expander RPS Remote Paging Sensor Temperature SensorProgramming the Outputs