Firstech, LLC CM3 SERIES, CM1000A, CM4200 manual Sec Anti-Jacking Ign Kill Enabled

Page 54

CM1000A

Option Menu 1

1

2

3

4

5

Feature

Factory Default

Lock/Unlock Pulse Duration

0.8 sec

Application of Pre-Wired Kill Relay

Starter Kill

Door Open Parking Light Indicator

Disabled

30 sec Passive Relock

Disabled

Double Pulse Unlock

Disabled

 

 

Optional

4 sec

Anti-Jacking (Ign Kill)

Enabled

Enabled

Enabled

These option descriptions are for the CM1000A ONLY. They differ from the regular option menus so much that they need their own section. The full listing of option menu descriptions immediately follows this page.

1.Lock / Unlock Pulse Duration

This option determines the output duration of the lock and unlock pulses Some Vehicles do not respond to short lock/unlock pulses.

2.Application of Pre-Wired Kill Relay

This option requires that the starter kill relay be installed in the ignition circuit, rather than into the starter circuit. With this option turned on, Panic mode will become Anti-Jacking mode. If Anti-Jacking is activated while the vehicle is running with the key in the ignition, the siren will sound for 30 seconds. After 30 seconds the system will break the ignition circuit, thereby disabling the vehicle. The siren will continue to play for 1 more minute. With this option turned off, when Panic mode is activated, the system will arm, activate the starter kill, and play the siren for 1.5 minutes.

3.Door Open Parking Light Indicator

With this option enabled, the parking lights will flash if a door is left open while the vehicle is being armed. This serves as a warning that all of the doors have not been closed.

4.30 sec Passive Relock

With this option enabled, after disarming the system with the remote, the system will relock the doors and arm the alarm after 30 seconds if a door has not been opened. At 10 and 20 seconds after the disarm command was given, the siren will chirp once to indicate that the alarm is about to rearm. At 30 seconds after, the siren will chirp once, and the system will arm the alarm. If you wish to stop this process, you must open a door within 30 seconds of disarming the alarm.

5.Double Pulse Unlock

With this option enabled, the unlock wire will perform a double pulse every time the unlock command is given. Some vehicles require this double pulse to operate the locks correctly.

- 54 -

Image 54
Contents Master Install Guide CM3 Series CM4200 CM1000A Page Table of Contents Install Checklist Remote Programming Procedures Page Remote Programming Procedures 1WFM6R 2WFMR-S,2WAMR, 2WFMR, and 2W900FMRPage Page Common Procedures Page Dipswitch and Jumper Settings Antenna MountingLittle Green Loop Adjusting Siren VolumeAdjusting Shock Sensor Sensitivity Programming Tach / Alternator Sensing Tach sensingDiagnosing Remote Start Problems Alternator sensingPage Control Modules Page CM3000 Wiring Diagram CN1 CN2 CN3 CN4 CN5 CN6 CN7CM-3000 Wiring Detail Connector Pin 1 Not used Pin 6 Not used Pin 8 Not usedPre-wired Shock Sensor Pre-wired Antenna Cable Page CM3300 Wiring Diagram CN1CM-3300 Wiring Detail Connector Pre-wired L.E.D Pre-wired Remote Paging Sensor or R.P.S Page CM4200 Wiring Diagram JM1CM-4200 Wiring Detail Connector Pin 1 Not used Optional Temperature sensor Page CM1000A Wiring Diagram CM-1000A Wiring Detail Connector Pre-wired L.E.D Option Programming Page Option Programming 1WAM4R, 1WFM4R, 1W900FM4R, and 1WSS4R R500A CM1000A 1WFM6R 2WFMR-S, 2WAMR, 2WFMR, and 2W900FMR2WSSR CM3 Series Option ProgrammerWay 4 Button Remotes All 2-Way Remotes CM3000 Option Menu Feature CM3300 Option Menu Feature CM4200 Option Menu Sec Anti-Jacking Ign Kill Enabled Options Explained In Detail CM3000-3300-4200 CM3000 CM4200 Page Additional Programming Page Installation Assistance Page Frequently Asked Questions / Troubleshooting How do I upgrade my current install to a higher end model? Vehicle will remote start when disarmed, but not when armedDo I have to hook up both 12v+ wires? Vehicle starts then shuts down 3 times in a rowCommon Diagrams Adding Door Actuators Trunk Release Transponder Passlock Passlock Aftermarket Turbo Timer with Parking Brake Trigger Starter Kill Relay Installation Page Page Page Accessory Manuals Page Stand Alone Mode OP500 Option ProgrammerConnector 1 Input Connector 2 OutputChannel Expander Temperature Sensor RPS Remote Paging SensorProgramming the Outputs