Wegener Communications 562 manual Normal Functions, Compel, System, Control

Page 26

Operation

 

Compel™

The iPump 562 IRD is most often controlled via the WEGENER Compel Control System.

System

This system is managed at the uplink site, sending a control stream with the usual audio

Control

and video data streams. The Compel System addresses units, and commands them to

 

perform various functions.

 

Among its functions is the ability to enable or limit aspects of local control. Also, Compel has

 

the ability to mute the audio and video of an IRD if it is inadvertently tuned to a frequency it

 

is not authorized to receive.

 

If an RF Switch option module is installed, Compel controls which of the four RF feeds is

 

being processed. For more information on this, see the Compel Manual, or contact your

 

service provider.

 

There are four levels of control via Compel. These levels are:

No Local Control - Push-buttons disabled

Read Only - No changes permitted

Limited - Changes may be made to Carrier Presets (pre-loaded values) only

Full - Full Local Control

3.2 Normal Functions

The iPump 562 allows several functions for basic operation and optimum performance.

Tune to a carrier

Configure LNB options

Monitor Signal Quality

Set Subtitling

Configure operating options:

Set Decoder options

Setup Audio

Set LAN IP Networking options

Set Terminal options

Set Printer options

Set User Relay

Set Date and Time information

Set Unit Label

Switch Application (to different software version)

Monitor status information:

View Signal Quality

Query Networking History

Display LAN IP Network information

Find Software Version information

Clear Statistics used for diagnosis

Play out play lists of media files

The functions listed above are illustrated below with instructions, OSD screens and other relevant information.

16

800092-01 Rev. A

www.wegener.com

Image 26
Contents IPump FCC Part 15B Class A, UL/C-UL1950 3rd EN5502498 800092-01 Rev. a First Edition JulyWegener Communications, Inc Table of Contents Controlling and Monitoring Erminal D Iagterm C Ommands This page intentionally left blank 800092-01 Rev. a List of Tables This page intentionally left blank 800092-01 Rev. a List of Figures 34 iPump 562 OSD Display Current Warnings Product Overview General InformationManual Overview Digital Media SeverCompel Network Con- trol IPump 562 Product SpecificationsFeatures and Options Rear PanelInput/Output ConnectionsExternal InterfacesConnector Input/Output Description Pdif Digital Audio Connector Input/Output DescriptionHdmi Digital Audio/Video Connector Input/Output Description External Input/Output InterfacesTechnical Specifica- tions RF CharacteristicsIPump 562 RF Characteristics Video Decoder IPump 562 Video DecoderComponent Video Output Composite Video OutputIPump 562 Composite Video Output Unbalanced Audio Output IPump 562 Component Video OutputAudio Decoder IPump 562 Unbalanced Audio OutputSerial Port LNB DC Power RF Port 1 onlyAC Power Local Hard Disk Driver HDD14 iPump 562 Physical Characteristics Safety SummaryPhysical Characteristics Physical CharacteristicsUnpacking and Inspection InstallationPrecautions Location and MountingReliable Earthing Desktop InstallationCircuit Overloading Rack MountingControlling and Monitoring Front Panel Controls IndicatorsOperation Menu Navigation using Push-buttons Push-buttonsAlarm Diagterm Terminal CommandsMode LED Status Condition NormalSystem Normal FunctionsCompel ControlCurrent Channel screen Carrier Settings screenTune to a carrier Channel Information Options Configure LNB optionsLNB Setup screen Signal Quality Setup screen Monitor Signal QualityLNB configuration options IPump 562 OSD Signal Quality Setup Screen Indicator Threshold screenSubtitling Setup screen Indicator Threshold screen optionsSignal Strength Meter screen Unit for Subtitling Setup screen optionsConfigure the Advanced Setup screen Operation11 iPump 562 OSD Advanced Setup Unit Setup screenSet Decoder Options Video Decoder OptionsSetup Audio Audio Output OptionsLAN Decode Options Select Activate SettingsSet LAN-based Decode options Set LAN IP Networking options10 Networking Configuration Settings Set Terminal optionsOption Possible values Console Baud-rate 11 Terminal OptionsSet Printer Options Set Date and Time information 12 User Relay Setup OptionsSet User Relay Option Possible values User Relay On/OffSet Unit Label 13 Date and Time Information SettingsSwitch Application to different software version Yes / NoMonitor Status Information Unit Status screenSignal Quality screen Current Quality screenHistory This Setting screen Signal Quality screenElapsed Times screen Query Network HistoryDisplay LAN IP Network information Find Software Version information29 iPump 562 OSD Version Info Clear Statistics used for diagnosisView Alarms/Warnings Play out play lists of media files32 iPump 562 OSD Main Menu 34 iPump 562 OSD Display Current Warnings This page intentionally left blank 800092-01 Rev. a Search Functions Perms/Temps/Searching & SettingsSettings Parameters for the iPump IPump 562 Settings Groups Settings Table or Search TableSignal Quality Monitoring General Rules Signal Quality InformationFrequency Tagging Parameter Description ModulationThis page intentionally left blank 800092-01 Rev. a Technical Support Customer ServiceWarranty Customer Service Table Apx 1.1 Diagterm Group Commands Appendix 1 Terminal Diagterm CommandsApx 1.1 Diagterm Group Commands Apx 1.2 Diagterm Individual Commands Table Apx 1.2 Diagterm Individual Commands 800092-01 Rev. a Appendix 2 Menu Tree Main Appendix 3 RMA Request Form Apx 3.1 Return Materials Authorization Request FormMail service@wegener.com Fax 678 This page intentionally left blank 800092-01 Rev. a Index NumericsPdif , 4 search