Wegener Communications 562 manual Settings Table or Search Table, Signal Quality Monitoring

Page 52

Search Functions

 

Table 4.2: iPump 562 Settings Groups

 

 

Settings

Description

Group

 

 

 

Temp

These settings are entered via Compel or the TEMP / TEMPCH terminal

 

commands. The unit is said to be inserting when it is configured to the temp

 

settings. The maximum length of an insert is approximately 18 hours (65535

 

seconds). An insert terminates when:

 

1. it times out,

 

2. an ABORT command is received,

 

3. power is cycled, or

 

4. an invalid header is seen.

 

Any Temp commands received while the receiver is currently inserting are ignored.

 

If a Perm command is received while inserting, the perm settings are updated but

 

not acted on until the insert is terminated.

 

 

Perm

The perm settings are entered via Compel, the PERM / PERMCH terminal, or

 

OSD Carrier Select screen, or automatically from within a search mode. (See

 

below.) The perm settings are the only settings group that are stored in NVRAM.

 

 

Search

The search settings are active while in Carrier Search or Header Search. When the

 

unit finds what it is looking for in the search mode, it copies the search settings to

 

the perm settings. These are then considered to be the active settings.

 

 

4.2 Settings Table (or Search Table)

This is an internal database retained in non-volatile memory (unaffected by loss of power). It contains a list of alternate carrier settings. Each valid entry is a complete description of a carrier/program setting (as used in a Perm command). This list is entered at customer request at the factory, and may be edited using Compel commands or ADDS and DELS terminal commands. The entries are referred to as "Table Entries" or "Search Settings Entries", etc.

The Settings Table is typically used for one of two possible operations. The first is for local users to quickly pre-program carrier/program combinations and tune the IRD to one of them. The second is as a source of alternate fallback carriers for times when the "normal" carrier is lost or has a failure in its Compel stream.

4.3 Signal Quality Monitoring

The iPump 562 provides monitoring of different parameters of RF signal quality while tracking a carrier.

Note: Beyond 15 dB, Eb/No readings are not accurate. For the following inner FEC ratios, display any Eb/No values above the limits shown as >xx dB: R=1/2, Eb/No >14.0 dB; R=2/3, Eb/No>13.5 dB; R=3/4, Eb/No>13.0 dB; R=5/6, Eb/No>12.5 dB; R=7/8, Eb/No>12.0 dB. Note that margin may also “top out” as a >yy dB value also.

42

800092-01 Rev. A

www.wegener.com

Image 52
Contents IPump Wegener Communications, Inc 800092-01 Rev. a First Edition JulyFCC Part 15B Class A, UL/C-UL1950 3rd EN5502498 Table of Contents Controlling and Monitoring Erminal D Iagterm C Ommands This page intentionally left blank 800092-01 Rev. a List of Tables This page intentionally left blank 800092-01 Rev. a List of Figures 34 iPump 562 OSD Display Current Warnings General Information Manual OverviewProduct Overview Digital Media SeverIPump 562 Product Specifications Features and OptionsCompel Network Con- trol Rear PanelConnections ExternalInput/Output InterfacesPdif Digital Audio Connector Input/Output Description Hdmi Digital Audio/Video Connector Input/Output DescriptionConnector Input/Output Description External Input/Output InterfacesIPump 562 RF Characteristics RF CharacteristicsTechnical Specifica- tions Video Decoder IPump 562 Video DecoderIPump 562 Composite Video Output Composite Video OutputComponent Video Output IPump 562 Component Video Output Audio DecoderUnbalanced Audio Output IPump 562 Unbalanced Audio OutputLNB DC Power RF Port 1 only AC PowerSerial Port Local Hard Disk Driver HDDSafety Summary Physical Characteristics14 iPump 562 Physical Characteristics Physical CharacteristicsInstallation PrecautionsUnpacking and Inspection Location and MountingDesktop Installation Circuit OverloadingReliable Earthing Rack MountingOperation Front Panel Controls IndicatorsControlling and Monitoring Menu Navigation using Push-buttons Push-buttonsDiagterm Terminal Commands Mode LED Status ConditionAlarm NormalNormal Functions CompelSystem ControlTune to a carrier Carrier Settings screenCurrent Channel screen LNB Setup screen Configure LNB optionsChannel Information Options LNB configuration options Monitor Signal QualitySignal Quality Setup screen IPump 562 OSD Signal Quality Setup Screen Indicator Threshold screenSignal Strength Meter screen Indicator Threshold screen optionsSubtitling Setup screen Subtitling Setup screen options Configure the Advanced Setup screenUnit for Operation11 iPump 562 OSD Advanced Setup Unit Setup screenSet Decoder Options Video Decoder OptionsSetup Audio Audio Output OptionsSelect Activate Settings Set LAN-based Decode optionsLAN Decode Options Set LAN IP Networking options10 Networking Configuration Settings Set Terminal optionsSet Printer Options 11 Terminal OptionsOption Possible values Console Baud-rate 12 User Relay Setup Options Set User RelaySet Date and Time information Option Possible values User Relay On/Off13 Date and Time Information Settings Switch Application to different software versionSet Unit Label Yes / NoMonitor Status Information Unit Status screenSignal Quality screen Current Quality screenHistory This Setting screen Signal Quality screenElapsed Times screen Query Network HistoryDisplay LAN IP Network information Find Software Version information29 iPump 562 OSD Version Info Clear Statistics used for diagnosisView Alarms/Warnings Play out play lists of media files32 iPump 562 OSD Main Menu 34 iPump 562 OSD Display Current Warnings This page intentionally left blank 800092-01 Rev. a Settings Parameters for the iPump Perms/Temps/Searching & SettingsSearch Functions Signal Quality Monitoring Settings Table or Search TableIPump 562 Settings Groups Signal Quality Information Frequency TaggingGeneral Rules Parameter Description ModulationThis page intentionally left blank 800092-01 Rev. a Warranty Customer ServiceTechnical Support Customer Service Apx 1.1 Diagterm Group Commands Appendix 1 Terminal Diagterm CommandsTable Apx 1.1 Diagterm Group Commands Apx 1.2 Diagterm Individual Commands Table Apx 1.2 Diagterm Individual Commands 800092-01 Rev. a Appendix 2 Menu Tree Main Mail service@wegener.com Fax 678 Apx 3.1 Return Materials Authorization Request FormAppendix 3 RMA Request Form This page intentionally left blank 800092-01 Rev. a Index NumericsPdif , 4 search