Wegener Communications 562 manual Set Decoder Options, Video Decoder Options

Page 34

Operation

LAN IP Networking

Carrier Settings

Terminal options

User Relay

Date and Time information

Unit Label settings

Switch Application

Set Video Decoder options

Set Decoder Options

Use following steps to display Decoder Setup screen on the OSD menu:

1.Navigate to the Unit Setup screen, see Unit Setup screen on page 23.

2.Press the down arrow button to select Decoder Setup.

3.View the details as shown in Figure 3.13.

Figure 3.13: iPump 562 OSD Decoder Setup

Use the Decoder Setup screen to set and display the decoder options.

Table 3.7: Video Decoder Options

 

Option

Possible values

Comments

 

 

 

 

 

 

 

 

Decoder Source

Follow Tune (currently selected

Controls source of input transport stream for the

 

 

 

RF source and program #) or Off

primary A/V decoder to play. The source can be either

 

 

 

(no A/V output)

Multicast UDP from Satellite/RF or Multi/Unicast UDP

 

 

 

 

from LAN/ETHERNET

 

 

 

 

 

 

 

 

TV Aspect Ratio

4x3 (Traditional TV) 16x9 (Wide

Allows the receiver to automatically correct a mismatch

 

 

 

screen TV) 14x9 (CiniView II)

in the aspect ratio of the TV to the content being

 

 

 

 

displayed.

 

 

 

 

 

 

 

 

Output Scaling

Letterbox (black bars either at

Optimizes viewing quality if the content does not match

 

 

 

top/bottom or at sides), Pan/Scan

the TV Aspect Ratio. In Pan/Scan mode, improvement

 

 

 

(display may be off screen)

in viewing experience depends on the source content.

 

 

 

 

 

 

 

Closed Captioning

PASSTHRU (ntsc/pal) or CC1:4

Sets the option to render subtitling information in

 

 

 

(EIA-608) orDTV (EIA-708-B)

different formats including Divicom.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

800092-01 Rev. A

www.wegener.com

Image 34
Contents IPump Wegener Communications, Inc 800092-01 Rev. a First Edition JulyFCC Part 15B Class A, UL/C-UL1950 3rd EN5502498 Table of Contents Controlling and Monitoring Erminal D Iagterm C Ommands This page intentionally left blank 800092-01 Rev. a List of Tables This page intentionally left blank 800092-01 Rev. a List of Figures 34 iPump 562 OSD Display Current Warnings Product Overview General InformationManual Overview Digital Media SeverCompel Network Con- trol IPump 562 Product SpecificationsFeatures and Options Rear PanelInput/Output ConnectionsExternal InterfacesConnector Input/Output Description Pdif Digital Audio Connector Input/Output DescriptionHdmi Digital Audio/Video Connector Input/Output Description External Input/Output InterfacesIPump 562 RF Characteristics RF CharacteristicsTechnical Specifica- tions Video Decoder IPump 562 Video DecoderIPump 562 Composite Video Output Composite Video OutputComponent Video Output Unbalanced Audio Output IPump 562 Component Video OutputAudio Decoder IPump 562 Unbalanced Audio OutputSerial Port LNB DC Power RF Port 1 onlyAC Power Local Hard Disk Driver HDD14 iPump 562 Physical Characteristics Safety SummaryPhysical Characteristics Physical CharacteristicsUnpacking and Inspection InstallationPrecautions Location and MountingReliable Earthing Desktop InstallationCircuit Overloading Rack MountingOperation Front Panel Controls IndicatorsControlling and Monitoring Menu Navigation using Push-buttons Push-buttonsAlarm Diagterm Terminal CommandsMode LED Status Condition NormalSystem Normal FunctionsCompel ControlTune to a carrier Carrier Settings screenCurrent Channel screen LNB Setup screen Configure LNB optionsChannel Information Options LNB configuration options Monitor Signal QualitySignal Quality Setup screen IPump 562 OSD Signal Quality Setup Screen Indicator Threshold screenSignal Strength Meter screen Indicator Threshold screen optionsSubtitling Setup screen Unit for Subtitling Setup screen optionsConfigure the Advanced Setup screen Operation11 iPump 562 OSD Advanced Setup Unit Setup screenSet Decoder Options Video Decoder OptionsSetup Audio Audio Output OptionsLAN Decode Options Select Activate SettingsSet LAN-based Decode options Set LAN IP Networking options10 Networking Configuration Settings Set Terminal optionsSet Printer Options 11 Terminal OptionsOption Possible values Console Baud-rate Set Date and Time information 12 User Relay Setup OptionsSet User Relay Option Possible values User Relay On/OffSet Unit Label 13 Date and Time Information SettingsSwitch Application to different software version Yes / NoMonitor Status Information Unit Status screenSignal Quality screen Current Quality screenHistory This Setting screen Signal Quality screenElapsed Times screen Query Network HistoryDisplay LAN IP Network information Find Software Version information29 iPump 562 OSD Version Info Clear Statistics used for diagnosisView Alarms/Warnings Play out play lists of media files32 iPump 562 OSD Main Menu 34 iPump 562 OSD Display Current Warnings This page intentionally left blank 800092-01 Rev. a Settings Parameters for the iPump Perms/Temps/Searching & SettingsSearch Functions Signal Quality Monitoring Settings Table or Search TableIPump 562 Settings Groups General Rules Signal Quality InformationFrequency Tagging Parameter Description ModulationThis page intentionally left blank 800092-01 Rev. a Warranty Customer ServiceTechnical Support Customer Service Apx 1.1 Diagterm Group Commands Appendix 1 Terminal Diagterm CommandsTable Apx 1.1 Diagterm Group Commands Apx 1.2 Diagterm Individual Commands Table Apx 1.2 Diagterm Individual Commands 800092-01 Rev. a Appendix 2 Menu Tree Main Mail service@wegener.com Fax 678 Apx 3.1 Return Materials Authorization Request FormAppendix 3 RMA Request Form This page intentionally left blank 800092-01 Rev. a Index NumericsPdif , 4 search