TOA Electronics C-RM500 operating instructions N T a C T, E L E C T C H, Contact

Page 26

6.4.3. Contact

Sets the alarm contact output terminal's operation.

Note

Contacts can only be set when "MASTER" has been selected in the "Operation mode" setting. This setting item is not displayed on the menu screen if "SLAVE" has been selected.

Step 1. Press the Menu key to display the menu screen.

Step 2. Tilt the joystick up or down to select "CONTACT" and confirm it with the SET key. The setting content will appear on Line 2.

C O N T A C T

1 . S E L E C T C H

Step 3. Tilt the joystick left or right to select one of the following setting contents, and confirm it with the SET key.

[Setting contents]

1. SELECTION CHANNEL

Makes the contact corresponding to the channel number (camera number)

 

when each channel is selected for full-screen display.

 

Also, if the connection of a switcher with 16 or more input channels has

 

been set, the channel number selected for full-screen display is converted

 

into binary data, and contacts 1 – 16 are assigned bits 0 – 15.

 

 

2. ALARM

Makes the contact corresponding to the alarm-activated channel number

 

(camera number) when the number of connected switcher inputs is 16 or

 

less and there is an alarm signal input to each channel.

 

Also, if 16 or more inputs are set, the last channel to receive an alarm

 

signal is converted into binary data, and contacts 1 – 16 are assigned bits

 

0 – 15. In the normal state, no contacts are enabled.

 

 

3. BOTH

In the normal state, the contact corresponding to the channel number

 

(camera number) is made when each channel is selected for full-screen

 

display. In the alarm state, when an alarm signal is input, the contact

 

corresponding to the channel number is made.

 

 

Notes

When "10. OTHER" has been selected in the "Switchers" settings, only "1. SELECTION CHANNEL" can be set.

This selection is set to "2. ALARM" by the factory.

26

Image 26
Contents Remote Controller Operating InstructionsTable of Contents Settings Safety Precautions Equipment Which Can Be Controlled with the C-RM500 General DescriptionFunctions About the Camera Control TerminalNomenclature and Functions TopAuxiliary contact key / Indicator *3 Lens speed key / Indicator *3Defroster key/Indicator *3 Auto key / Indicator *3Rear Operation Operating the CameraF R O S T E R N U a LP E R X I L I a R Y S WActivating the zoom function T OActivating the automatic functions Activating the focus functionChanging the lens speed T O F O C U SO S I T I O N Activating the auto-focus functionA N N E L C a L L When confirming the camera number and operating its displayMonitor Display Operation keysSimultaneously resetting all freeze displays Resetting individual freeze displaysU N C T I O N K E Y Using the Function keysUsing the abbreviated numbers E TViewing full-screen displays H a N N E LE G M E N T Monitor screen Group E G M E N T Viewing sequential displays Sequential full-screen viewing Q U E N C EE G S E Q Sequential 4-segment split-screen viewingAlarm Hold and Reset Alarm H O L DSettings Setting Items and Their DescriptionsLCD screen display Keys to be used in setting operationsOperating Keys and Display Screen E R a T I O N M O D E Basic Setting Operations S S W O R D T O R E T U R NSetting contents Setting the FunctionsOperation mode E R a T I O N M O D E 1 . M a S T E R6 I N P U T SwitchersI T C H E R M a R TContact N T a C TE L E C T C H T O T U R N Automatic resetT O R E T U R N 1 . O N E CR a C E Home position selector terminal operation settingsR a C E 2 P O S Home position4 0 S P E E DM E R a M O T EZ Z E R 1 . O N I T I a L S C R E E N 1 . F U L LBuzzer Initial screenI T I a L C H a N N E L Channel designationSensor alarm N S O R Alarm 1 . O NM E R a Alarm 1 . O N Camera alarmCamera check Camera alarm preset Alarm time Alarm S I G N a L 1 . E D G EAlarm signal Alarm hold Alarm F U N C T I O N 1 . S E QAlarm H O L D 1 . K E Y M 1 5 P O S 1 2 N C T I O N K E YM 1 N C T I O N K E Y a a U T O P a NAbbreviation Setting the cameras alarm contact outputM 2 Tour sequence 0 S E C2 3 P 0 S E C Press the Menu key to display the menu screenCamera menu PasswordM E R a M E N U C H Example ConnectionsSystem Examples Example Connection cables Connected Camera Termination Switch SettingConnection to Combination Cameras Connection to the Multi-Switchers RS-232C Terminal Fixed camera Connection to the Smart Switchers RS-232C Terminal Shielded twisted-pair cable RS-232C reverse cable Connection When Controlling the System from 2 Locations RM500 Slave Speed SwitcherAlarm Output/Control Input Terminal Connections Assembling D-sub connectors onto cables Modifications SpecificationsAccessories 133-12-743-6E