6.4.20. Tour sequence

The Tour Sequence function switches multiple camera outputs in sequence at a set time interval. Merely pressing the Sequence key permits up to 128 camera outputs to be displayed on the full screen in the order of their set playback number. The camera number, position number and viewing time can be set for individual playback numbers.

Step 1. Press the Menu key to display the menu screen.

T O U R S E Q

N

O

(Set by the factory)

Step 2. Tilt the joystick up or down to select "TOUR SEQ"

and confirm the selection with the SET key.

The unit will wait for the entry of "YES" (to use the function) or "NO" (to not use the function). (Set by the factory)

Step 3. Tilt the joystick to the left or right to select either "YES" or "NO," and confirm the entry by pressing the SET key.

The setting is displayed on Line 2 if "YES" is selected, and the unit switched to Playback Number Entry Waiting mode.

Note that when the camera number or the position

number is not programmed in advance, the " " indication is displayed in place of the number.

Step 4. Enter the playback number using the numeric keypad or by tilting the joystick to the left or right, and confirm the entered number with the SET key.

Enter a number from 1 to 128.

The flashing cursor moves to the camera number.

Step 5. Enter the camera number with the numeric keypad, and confirm the number with the SET key.

Enter a number from 1 to 999.

The flashing cursor moves to the position number.

Step 6. Enter the position number with the numeric keypad, and confirm the number with the SET key.

Enter a number from 1 to 255.

Tip: Entering "0" will switch the screen to full- screen display, and does not execute position playback.

The flashing cursor moves to the rightmost viewing interval selection indication on Line 2.

Step 7. Tilt the joystick to the left or right to select the viewing interval: "3SEC," "10SEC," "15SEC," "20SEC," "30SEC," or "1MIN." (SEC: seconds, MIN: minutes)

Step 8. Press the SET key to confirm the set interval. The procedure returns to Step 4.

Step 9. Repeat Steps 4 – 8 to continue setting the playback numbers.

Press the Clear key to return to the setting item display.

[Deleting Settings]

After pressing the Alarm Reset key, press the SET key.

T O U R

S E Q

Y E S

 

 

 

 

3

(Example)

 

 

 

 

SET

 

 

 

 

 

 

 

 

T O U R

S E Q

 

1

No.

 

 

 

 

C

P

T 1 0 S E C

 

 

 

 

(Example)

 

 

 

 

4

UP

 

 

 

 

LEFT

RIGHT

1

SET

 

 

 

 

 

DOWN

or

 

 

 

 

 

 

 

T O U R

S E Q

 

1

 

 

C

P

T 1 0 S E C

 

 

 

5

(Example)

 

 

 

 

1

2

3

SET

 

 

 

 

 

T O U R

S E Q

 

1

 

 

C 1 2 3 P

T 1 0 S E C

 

 

 

6

(Example)

 

 

 

 

2

0

0

SET

 

 

 

 

 

T O U R

S E Q

 

1

 

 

C 1 2 3 P 2 0 0 T 1 0 S E C

 

 

 

7

UP

 

 

 

 

LEFT

RIGHT

 

 

 

 

DOWN

 

 

 

T O U R

S E Q

 

1

 

 

C 1 2 3 P 2 0 0 T 1 0 S E C

 

 

 

8

SET

 

 

 

 

 

 

 

 

 

 

 

 

 

39

Image 39
Contents Operating Instructions Remote ControllerTable of Contents Settings Safety Precautions About the Camera Control Terminal General DescriptionFunctions Equipment Which Can Be Controlled with the C-RM500Top Nomenclature and FunctionsAuto key / Indicator *3 Lens speed key / Indicator *3Defroster key/Indicator *3 Auxiliary contact key / Indicator *3Rear Operating the Camera OperationX I L I a R Y S W N U a LP E R F R O S T E RActivating the focus function T OActivating the automatic functions Activating the zoom functionActivating the auto-focus function T O F O C U SO S I T I O N Changing the lens speedOperation keys When confirming the camera number and operating its displayMonitor Display A N N E L C a L LResetting individual freeze displays Simultaneously resetting all freeze displaysE T Using the Function keysUsing the abbreviated numbers U N C T I O N K E YH a N N E L E G M E N TViewing full-screen displays Monitor screen Group E G M E N T Sequential 4-segment split-screen viewing Q U E N C EE G S E Q Viewing sequential displays Sequential full-screen viewingAlarm H O L D Alarm Hold and ResetSetting Items and Their Descriptions SettingsKeys to be used in setting operations Operating Keys and Display ScreenLCD screen display T O R E T U R N Basic Setting OperationsS S W O R D E R a T I O N M O D EE R a T I O N M O D E 1 . M a S T E R Setting the FunctionsOperation mode Setting contentsM a R T SwitchersI T C H E R 6 I N P U TN T a C T E L E C T C HContact E C Automatic resetT O R E T U R N 1 . O N T O T U R NHome position Home position selector terminal operation settingsR a C E 2 P O S R a C EM O T E S P E E DM E R a 4 0Initial screen I T I a L S C R E E N 1 . F U L LBuzzer Z Z E R 1 . O NChannel designation I T I a L C H a N N E LCamera alarm N S O R Alarm 1 . O NM E R a Alarm 1 . O N Sensor alarmCamera check Camera alarm preset Alarm S I G N a L 1 . E D G E Alarm signalAlarm time Alarm F U N C T I O N 1 . S E Q Alarm H O L D 1 . K E Y Alarm hold N C T I O N K E Y a a U T O P a N N C T I O N K E YM 1 M 1 5 P O S 1 2Setting the cameras alarm contact output M 2Abbreviation Press the Menu key to display the menu screen 0 S E C2 3 P 0 S E C Tour sequencePassword M E R a M E N U C HCamera menu Connections System ExamplesExample Example Connected Camera Termination Switch Setting Connection to Combination CamerasConnection cables Connection to the Multi-Switchers RS-232C Terminal Fixed camera Connection to the Smart Switchers RS-232C Terminal Shielded twisted-pair cable RS-232C reverse cable RM500 Slave Speed Switcher Connection When Controlling the System from 2 LocationsAlarm Output/Control Input Terminal Connections Assembling D-sub connectors onto cables Specifications AccessoriesModifications 133-12-743-6E