C-RM500

Camera control terminal

Switcher control terminal

Alarm input terminal

 

 

 

 

 

GND

 

 

RS-232C

RS-232C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232C reverse cable

Female D-sub 9-pin connector to Female D-sub 9-pin connector

Fixed camera

Shielded twisted-pair cable

RS-232C reverse cable

 

Female D-sub 9-pin connector to

 

Female D-sub 9-pin connector

Smart switcher

 

 

 

 

 

 

 

 

 

 

 

 

MONITOR

1

2

3

4

5

6

7

8

 

 

 

(SP/SQ)

 

 

 

 

 

 

 

 

 

 

 

IN

 

 

 

VIDEO

 

 

 

 

 

 

VIDEO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

 

 

 

 

 

 

 

 

 

 

 

RS-232C

 

 

 

 

 

 

 

 

A

1

 

1

 

 

 

 

 

 

 

 

B

2

Camera control

Alarm input

 

 

 

 

 

 

 

 

A

3

cable

cable

 

 

 

 

 

 

 

 

B

4

 

4

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

Combination camera

5, 10

Sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Camera control

Alarm input

 

 

 

 

 

 

 

Monitor TV

 

3

cable

cable

 

 

 

 

 

 

 

 

 

4

 

4

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

Combination camera

5, 10

Sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The use of each camera's alarm input permits connection of 8 sensors for each camera.

Sensor

Alarm input unit C-AL80

ALARM/REMOTE IN

RS-232C

47

Image 47
Contents Operating Instructions Remote ControllerTable of Contents Settings Safety Precautions About the Camera Control Terminal General DescriptionFunctions Equipment Which Can Be Controlled with the C-RM500Top Nomenclature and FunctionsAuto key / Indicator *3 Lens speed key / Indicator *3Defroster key/Indicator *3 Auxiliary contact key / Indicator *3Rear Operating the Camera OperationX I L I a R Y S W N U a LP E R F R O S T E RActivating the focus function T OActivating the automatic functions Activating the zoom functionActivating the auto-focus function T O F O C U SO S I T I O N Changing the lens speedOperation keys When confirming the camera number and operating its displayMonitor Display A N N E L C a L LResetting individual freeze displays Simultaneously resetting all freeze displaysE T Using the Function keysUsing the abbreviated numbers U N C T I O N K E YViewing full-screen displays H a N N E LE G M E N T Monitor screen Group E G M E N T Sequential 4-segment split-screen viewing Q U E N C EE G S E Q Viewing sequential displays Sequential full-screen viewingAlarm H O L D Alarm Hold and ResetSetting Items and Their Descriptions SettingsLCD screen display Keys to be used in setting operationsOperating Keys and Display Screen T O R E T U R N Basic Setting OperationsS S W O R D E R a T I O N M O D EE R a T I O N M O D E 1 . M a S T E R Setting the FunctionsOperation mode Setting contentsM a R T SwitchersI T C H E R 6 I N P U TContact N T a C TE L E C T C H E C Automatic resetT O R E T U R N 1 . O N T O T U R NHome position Home position selector terminal operation settingsR a C E 2 P O S R a C EM O T E S P E E DM E R a 4 0Initial screen I T I a L S C R E E N 1 . F U L LBuzzer Z Z E R 1 . O NChannel designation I T I a L C H a N N E LCamera alarm N S O R Alarm 1 . O NM E R a Alarm 1 . O N Sensor alarmCamera check Camera alarm preset Alarm time Alarm S I G N a L 1 . E D G EAlarm signal Alarm hold Alarm F U N C T I O N 1 . S E QAlarm H O L D 1 . K E Y N C T I O N K E Y a a U T O P a N N C T I O N K E YM 1 M 1 5 P O S 1 2Abbreviation Setting the cameras alarm contact outputM 2 Press the Menu key to display the menu screen 0 S E C2 3 P 0 S E C Tour sequenceCamera menu PasswordM E R a M E N U C H Example ConnectionsSystem Examples Example Connection cables Connected Camera Termination Switch SettingConnection to Combination Cameras Connection to the Multi-Switchers RS-232C Terminal Fixed camera Connection to the Smart Switchers RS-232C Terminal Shielded twisted-pair cable RS-232C reverse cable RM500 Slave Speed Switcher Connection When Controlling the System from 2 LocationsAlarm Output/Control Input Terminal Connections Assembling D-sub connectors onto cables Modifications SpecificationsAccessories 133-12-743-6E