27.Position key

Orients the Combination camera toward the set direction. The Position key can only be used when the Control indicator is on. Pressing the Position key without designating the position number orients the camera toward the direction programmed under Position No. 1 (Home position).

28.Control key *2 / Indicator

Used to designate the camera to be manually

controlled during a multi-screen display. This key cannot be used during a full-screen or sequential display. Also, nothing is operated even if this key is pressed without designating the channel number. The indicator lights when the camera is controllable.

29. Full-screen key

Displays the designated camera output on the full screen. This key cannot be used unless the camera number is entered.

[Rear]

30

31

32

33 34

35

36

37

38

[Bottom] (Function indications for the rear parts)

GND

GND

GND

GND GND

CAMERA SWITCHER

REMOTE

DC IN

39

12V

 

REMOTE CONTROLLER model C-RM500 120

12V 150mA Class2

SWITCHER

ALARM IN

ALARM OUT

DC IN 12V

TOA Corporation

MADE IN JAPAN

30.Camera control terminal (RS-485) Connects to the Combination camera.

31.Switcher control terminal (RS-485)

Connects to the Multi-Switcher's dedicated remote control terminal, and controls the Switcher's screen display.

32.Slave unit remote control terminal

Connects to another C-RM500 Remote Controller to be designated as a slave unit for remote control from different locations.

33.Power input terminal [DC IN 12 V] *4

Used to supply power from a source other than the supplied AC adapter.

34.Ground Terminal [GND]

Please ground by the cable that attached the supplied clamp filter.

 

1turn

GND

GND

Terminal

 

 

clamp filter

(Please attach a clamp filter to the nearest possible position of this controller.)

35.Switcher control terminal (RS-232C) Connects to the RS-232C I/O terminal of the Multi-Switcher and Smart Switcher to control these switchers.

36.Alarm input terminal (RS-232C)

Connects to an alarm input unit to receive alarm signals. This terminal is also a serial I/O terminal that functions as an interface with external systems.

37.Alarm output / Control input terminal

Makes contact corresponding to the alarm- activated channel (camera number).

38.AC adapter power input terminal [DC IN 12 V] *4 Insert the DC plug of the dedicated AC adapter into this terminal.

39.Rating label

8

Image 8
Contents Remote Controller Operating InstructionsTable of Contents Settings Safety Precautions General Description Functions Equipment Which Can Be Controlled with the C-RM500 About the Camera Control TerminalNomenclature and Functions TopLens speed key / Indicator *3 Defroster key/Indicator *3Auxiliary contact key / Indicator *3 Auto key / Indicator *3Rear Operation Operating the CameraN U a L P E RF R O S T E R X I L I a R Y S WT O Activating the automatic functionsActivating the zoom function Activating the focus functionT O F O C U S O S I T I O NChanging the lens speed Activating the auto-focus functionWhen confirming the camera number and operating its display Monitor DisplayA N N E L C a L L Operation keysSimultaneously resetting all freeze displays Resetting individual freeze displaysUsing the Function keys Using the abbreviated numbersU N C T I O N K E Y E TViewing full-screen displays H a N N E LE G M E N T Monitor screen Group E G M E N T Q U E N C E E G S E QViewing sequential displays Sequential full-screen viewing Sequential 4-segment split-screen viewingAlarm Hold and Reset Alarm H O L DSettings Setting Items and Their DescriptionsLCD screen display Keys to be used in setting operationsOperating Keys and Display Screen Basic Setting Operations S S W O R DE R a T I O N M O D E T O R E T U R NSetting the Functions Operation modeSetting contents E R a T I O N M O D E 1 . M a S T E RSwitchers I T C H E R6 I N P U T M a R TContact N T a C TE L E C T C H Automatic reset T O R E T U R N 1 . O NT O T U R N E CHome position selector terminal operation settings R a C E 2 P O SR a C E Home positionS P E E D M E R a4 0 M O T EI T I a L S C R E E N 1 . F U L L BuzzerZ Z E R 1 . O N Initial screenI T I a L C H a N N E L Channel designationN S O R Alarm 1 . O N M E R a Alarm 1 . O NSensor alarm Camera alarmCamera check Camera alarm preset Alarm time Alarm S I G N a L 1 . E D G EAlarm signal Alarm hold Alarm F U N C T I O N 1 . S E QAlarm H O L D 1 . K E Y N C T I O N K E Y M 1M 1 5 P O S 1 2 N C T I O N K E Y a a U T O P a NAbbreviation Setting the cameras alarm contact outputM 2 0 S E C 2 3 P 0 S E CTour sequence Press the Menu key to display the menu screenCamera menu PasswordM E R a M E N U C H Example ConnectionsSystem Examples Example Connection cables Connected Camera Termination Switch SettingConnection to Combination Cameras Connection to the Multi-Switchers RS-232C Terminal Fixed camera Connection to the Smart Switchers RS-232C Terminal Shielded twisted-pair cable RS-232C reverse cable Connection When Controlling the System from 2 Locations RM500 Slave Speed SwitcherAlarm Output/Control Input Terminal Connections Assembling D-sub connectors onto cables Modifications SpecificationsAccessories 133-12-743-6E