TOA Electronics C-RM500 General Description, Functions, About the Camera Control Terminal

Page 5

2. GENERAL DESCRIPTION

The TOA C-RM500 Remote Controller is used to remotely control TOA's Combination cameras over communication lines (RS-485). It can remotely control video image switching and cameras in combination with TOA's Multi-Switcher or Smart Switcher.

3. FUNCTIONS

Display Selection

The following screen formats can be selected for display of camera images connected to the Multi-Switcher: full screen, 4-segment, sequential 4-segment, 9-segment, 10-segment or 16-segment split-screen and sequential full-screen.

Manual Operation

Controls the Combination camera's zoom, focus, pan and tilt functions.

Camera Position Selection

Controls the Combination camera's orientation, and displays the camera image on the monitor in the selected orientation.

Function Key Programming

Camera numbers or camera number/position combinations can be programmed into the function keys (A – H). Pressing the function key displays the camera image on the full screen. If position numbers have been set, images of the selected camera orientation can be displayed.

Abbreviated Number Display

Permits camera numbers or camera number/position combinations to be programmed for numbers 1 – 512. Entering the programmed number followed by the SET key displays the corresponding camera number on the full screen, and the image of selected camera orientation if the position number has been set.

Alarm Function

Controls the display in synchronization with alarm signals received from a camera. When an alarm signal is detected, the image of the corresponding camera takes display precedence. The C-RM500 Controller also features an Alarm Hold function that temporarily disables channel (camera number) switching in response to an alarm signal. This prevents the display from being forcibly switched to an alerted camera during close inspection (when the Multi-Switcher is connected).

Equipment Which Can Be Controlled with the C-RM500

Shown below are equipment that can be controlled with the C-RM500.

Camera: C-CC501, C-CC504, C-CC551, and C-CC554

Up to 31 cameras can be connected to the unit's Camera control terminal and controlled. The use of the C-IF500 Interface Unit will increase the number to up to 64 cameras (when the C-SS8 switcher is in use). Note that the cameras cannot be controlled if their number is greater than the number of inputs of a connected switcher.

Switcher: C-MS90D, C-MS90S, C-MS160D, C-MS160S, and C-SS8

Only one switcher can be connected for remote camera control. However, as to the C-SS8, 1 master-designated unit and up to 7 slave-designated units can be connected to remotely control the cameras.

About the Camera Control Terminal

The Camera control terminal is used to connect the C-CC501, C-CC504, C-CC551, or C-CC554 Combination Camera or the C-IF500 Interface Unit. Up to 31 pieces of equipment can be connected to the terminal.

About the Descriptions in This Manual

The explanations in this manual assume that the C-RM500 Remote Controller is connected to a C-MS160D/S or C-MS90D/S Multi-Switcher and the C-SS8 Smart Switcher.

Camera number: Refers to the camera input terminal number connected to the switcher.

Position number: Combination camera orientation can be programmed for No. 1 – 255.

5

Image 5
Contents Operating Instructions Remote Controller Table of Contents Settings Safety Precautions Functions General DescriptionEquipment Which Can Be Controlled with the C-RM500 About the Camera Control TerminalTop Nomenclature and FunctionsDefroster key/Indicator *3 Lens speed key / Indicator *3Auxiliary contact key / Indicator *3 Auto key / Indicator *3Rear Operating the Camera OperationP E R N U a LF R O S T E R X I L I a R Y S WActivating the automatic functions T OActivating the zoom function Activating the focus functionO S I T I O N T O F O C U SChanging the lens speed Activating the auto-focus functionMonitor Display When confirming the camera number and operating its displayA N N E L C a L L Operation keysResetting individual freeze displays Simultaneously resetting all freeze displaysUsing the abbreviated numbers Using the Function keysU N C T I O N K E Y E TViewing full-screen displays H a N N E LE G M E N T Monitor screen Group E G M E N T E G S E Q Q U E N C EViewing sequential displays Sequential full-screen viewing Sequential 4-segment split-screen viewingAlarm H O L D Alarm Hold and ResetSetting Items and Their Descriptions SettingsLCD screen display Keys to be used in setting operationsOperating Keys and Display Screen S S W O R D Basic Setting OperationsE R a T I O N M O D E T O R E T U R NOperation mode Setting the FunctionsSetting contents E R a T I O N M O D E 1 . M a S T E RI T C H E R Switchers6 I N P U T M a R TContact N T a C TE L E C T C H T O R E T U R N 1 . O N Automatic resetT O T U R N E CR a C E 2 P O S Home position selector terminal operation settingsR a C E Home positionM E R a S P E E D4 0 M O T EBuzzer I T I a L S C R E E N 1 . F U L LZ Z E R 1 . O N Initial screenChannel designation I T I a L C H a N N E LM E R a Alarm 1 . O N N S O R Alarm 1 . O NSensor alarm Camera alarmCamera check Camera alarm preset Alarm time Alarm S I G N a L 1 . E D G EAlarm signal Alarm hold Alarm F U N C T I O N 1 . S E QAlarm H O L D 1 . K E Y M 1 N C T I O N K E YM 1 5 P O S 1 2 N C T I O N K E Y a a U T O P a NAbbreviation Setting the cameras alarm contact outputM 2 2 3 P 0 S E C 0 S E CTour sequence Press the Menu key to display the menu screenCamera menu PasswordM E R a M E N U C H Example ConnectionsSystem Examples Example Connection cables Connected Camera Termination Switch SettingConnection to Combination Cameras Connection to the Multi-Switchers RS-232C Terminal Fixed camera Connection to the Smart Switchers RS-232C Terminal Shielded twisted-pair cable RS-232C reverse cable RM500 Slave Speed Switcher Connection When Controlling the System from 2 LocationsAlarm Output/Control Input Terminal Connections Assembling D-sub connectors onto cables Modifications SpecificationsAccessories 133-12-743-6E