TOA Electronics C-RM500 Alarm S I G N a L 1 . E D G E, Alarm signal, Alarm time

Page 35

6.4.14. Alarm signal

Sets continuous alarm operations.

Step 1. Press the Menu key to display the menu screen.

Step 2. Tilt the joystick up or down to select "ALARM SIGNAL," and confirm the selection with the SET key. The setting is displayed on Line 2.

A L A R M S I G N A L 1 . E D G E

Step 3. Tilt the joystick to the left or right to select either of the following settings, and confirm it with the SET key.

[Setting contents]

1.

EDGE

Terminates alarm operations when the time interval set in the "Alarm time" setting (next

 

 

item) passes or when an alarm reset signal is received.

 

 

 

2.

LEVEL

Terminates alarm operations when the alarm input terminal receives alarm end data. Also,

 

 

if "1. ON" has been selected in the "Camera alarm" setting, alarm operation will stop when

 

 

all alarm signals from the camera change from make to break data.

 

 

 

Note: This selection is set to "1. EDGE" by the factory.

6.4.15. Alarm time

Sets the interval between alarm input and alarm reset.

Note

The Alarm Time can only be set when "1. EDGE" has been selected in the "Alarm signal" setting. This setting item is not displayed on the menu screen when "2. LEVEL" has been selected.

Step 1. Press the Menu key to display the menu screen.

Step 2. Tilt the joystick up or down to select "ALARM TIME," and confirm the selection with the SET key. The setting is displayed on Line 2.

A L A R M T I M E 3 . 2 0 S E C

Step 3. Tilt the joystick to the left or right to select one of the following settings, and confirm it with the SET key.

[Setting contents]

1.

10SEC

(10 seconds)

6.

2MIN

(2 minutes)

2.

15SEC

(15 seconds)

7.

3MIN

(3 minutes)

 

 

 

 

 

 

3.

20SEC

(20 seconds)

8.

4MIN

(4 minutes)

 

 

 

 

 

 

4.

30SEC

(30 seconds)

9.

5MIN

(5 minutes)

5.

1MIN

(1 minute)

10.

NO LIMIT

(no time limit)

 

 

 

 

 

 

Notes

If "10. NO LIMIT" is selected, the alarm can only be reset when the Alarm Reset key on the unit's top panel is pressed.

This selection is set to "3. 20SEC" by the factory.

35

Image 35
Contents Operating Instructions Remote ControllerTable of Contents Settings Safety Precautions About the Camera Control Terminal General DescriptionFunctions Equipment Which Can Be Controlled with the C-RM500Top Nomenclature and FunctionsAuto key / Indicator *3 Lens speed key / Indicator *3Defroster key/Indicator *3 Auxiliary contact key / Indicator *3Rear Operating the Camera OperationX I L I a R Y S W N U a LP E R F R O S T E RActivating the focus function T OActivating the automatic functions Activating the zoom functionActivating the auto-focus function T O F O C U SO S I T I O N Changing the lens speedOperation keys When confirming the camera number and operating its displayMonitor Display A N N E L C a L LResetting individual freeze displays Simultaneously resetting all freeze displaysE T Using the Function keysUsing the abbreviated numbers U N C T I O N K E YViewing full-screen displays H a N N E LE G M E N T Monitor screen Group E G M E N T Sequential 4-segment split-screen viewing Q U E N C EE G S E Q Viewing sequential displays Sequential full-screen viewingAlarm H O L D Alarm Hold and ResetSetting Items and Their Descriptions SettingsLCD screen display Keys to be used in setting operationsOperating Keys and Display Screen T O R E T U R N Basic Setting OperationsS S W O R D E R a T I O N M O D EE R a T I O N M O D E 1 . M a S T E R Setting the FunctionsOperation mode Setting contentsM a R T SwitchersI T C H E R 6 I N P U TContact N T a C TE L E C T C H E C Automatic resetT O R E T U R N 1 . O N T O T U R NHome position Home position selector terminal operation settingsR a C E 2 P O S R a C EM O T E S P E E DM E R a 4 0Initial screen I T I a L S C R E E N 1 . F U L LBuzzer Z Z E R 1 . O NChannel designation I T I a L C H a N N E L Camera alarm N S O R Alarm 1 . O N M E R a Alarm 1 . O N Sensor alarmCamera check Camera alarm preset Alarm time Alarm S I G N a L 1 . E D G EAlarm signal Alarm hold Alarm F U N C T I O N 1 . S E QAlarm H O L D 1 . K E Y N C T I O N K E Y a a U T O P a N N C T I O N K E YM 1 M 1 5 P O S 1 2Abbreviation Setting the cameras alarm contact outputM 2 Press the Menu key to display the menu screen 0 S E C2 3 P 0 S E C Tour sequenceCamera menu PasswordM E R a M E N U C H Example ConnectionsSystem Examples Example Connection cables Connected Camera Termination Switch SettingConnection to Combination Cameras Connection to the Multi-Switchers RS-232C Terminal Fixed camera Connection to the Smart Switchers RS-232C Terminal Shielded twisted-pair cable RS-232C reverse cable RM500 Slave Speed Switcher Connection When Controlling the System from 2 LocationsAlarm Output/Control Input Terminal Connections Assembling D-sub connectors onto cables Modifications SpecificationsAccessories 133-12-743-6E